The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive
BACKGROUND. This study aimed to measure the shear bond strength and compressive strength of orthodontic adhesives at different curing times and intensities. METHODS. Ninety extracted human premolars were used. Orthodontic brackets were bonded on the buccal surface of the teeth with orthodontic adhes...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462919/ https://www.ncbi.nlm.nih.gov/pubmed/37650018 http://dx.doi.org/10.34172/joddd.2023.36990 |
_version_ | 1785098140657909760 |
---|---|
author | Mohammed, Omar K. Younis, Mohammed T. Dawood, Alaa E. |
author_facet | Mohammed, Omar K. Younis, Mohammed T. Dawood, Alaa E. |
author_sort | Mohammed, Omar K. |
collection | PubMed |
description | BACKGROUND. This study aimed to measure the shear bond strength and compressive strength of orthodontic adhesives at different curing times and intensities. METHODS. Ninety extracted human premolars were used. Orthodontic brackets were bonded on the buccal surface of the teeth with orthodontic adhesive light-cured using VRN-VAFU LED curing light at different curing times (1, 3 and 5 seconds) and intensities (1000, 1600 and 2300 mW/cm(2) ). A universal testing machine was used to measure the shear bond strength. The ratio of the adhesive remnant and compressive strength of the orthodontic adhesive, at each curing time at the different intensities, were also evaluated. The results were statistically analyzed using one-way analysis of variance followed by Tukey’s test. RESULTS. The lowest bond strength values (6.4, 9.9 and 12.6 MPa) were recorded with 1000 mW/ cm(2) intensity (at all curing times) in comparison with the other intensities (P<0.05). Increasing the curing time significantly increased the bond strength of the orthodontic brackets (P<0.05), except when the curing time was increased from 3 sec to 5 sec at 1600 mW/cm(2) intensity. The highest compressive strength values (130.3, 147.1 and 174 MPa) were recorded at 2300 mW/ cm(2) intensity (at all curing times) compared to the other intensities (P<0.05). The highest values of the ratio of the adhesive remnants were recorded at 1000 mW/cm(2) intensity (at all curing times) compared to the other intensities (P<0.05). CONCLUSION. Although, increasing the curing time and\or the curing intensity has a positive effect on the bond strength and compressive strength of the orthodontic adhesive, it might be possible to suggest reducing the curing time of orthodontic adhesive to 1 sec at curing intensity of 2300 mW/cm(2). |
format | Online Article Text |
id | pubmed-10462919 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Tabriz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-104629192023-08-30 The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive Mohammed, Omar K. Younis, Mohammed T. Dawood, Alaa E. J Dent Res Dent Clin Dent Prospects Original Article BACKGROUND. This study aimed to measure the shear bond strength and compressive strength of orthodontic adhesives at different curing times and intensities. METHODS. Ninety extracted human premolars were used. Orthodontic brackets were bonded on the buccal surface of the teeth with orthodontic adhesive light-cured using VRN-VAFU LED curing light at different curing times (1, 3 and 5 seconds) and intensities (1000, 1600 and 2300 mW/cm(2) ). A universal testing machine was used to measure the shear bond strength. The ratio of the adhesive remnant and compressive strength of the orthodontic adhesive, at each curing time at the different intensities, were also evaluated. The results were statistically analyzed using one-way analysis of variance followed by Tukey’s test. RESULTS. The lowest bond strength values (6.4, 9.9 and 12.6 MPa) were recorded with 1000 mW/ cm(2) intensity (at all curing times) in comparison with the other intensities (P<0.05). Increasing the curing time significantly increased the bond strength of the orthodontic brackets (P<0.05), except when the curing time was increased from 3 sec to 5 sec at 1600 mW/cm(2) intensity. The highest compressive strength values (130.3, 147.1 and 174 MPa) were recorded at 2300 mW/ cm(2) intensity (at all curing times) compared to the other intensities (P<0.05). The highest values of the ratio of the adhesive remnants were recorded at 1000 mW/cm(2) intensity (at all curing times) compared to the other intensities (P<0.05). CONCLUSION. Although, increasing the curing time and\or the curing intensity has a positive effect on the bond strength and compressive strength of the orthodontic adhesive, it might be possible to suggest reducing the curing time of orthodontic adhesive to 1 sec at curing intensity of 2300 mW/cm(2). Tabriz University of Medical Sciences 2023 2023-04-03 /pmc/articles/PMC10462919/ /pubmed/37650018 http://dx.doi.org/10.34172/joddd.2023.36990 Text en ©2023 The Author(s). https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium provided the original work is properly cited. |
spellingShingle | Original Article Mohammed, Omar K. Younis, Mohammed T. Dawood, Alaa E. The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive |
title | The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive |
title_full | The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive |
title_fullStr | The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive |
title_full_unstemmed | The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive |
title_short | The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive |
title_sort | effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462919/ https://www.ncbi.nlm.nih.gov/pubmed/37650018 http://dx.doi.org/10.34172/joddd.2023.36990 |
work_keys_str_mv | AT mohammedomark theeffectoflightcuringtimeandintensityonthebondstrengthandfractureresistanceoforthodonticadhesive AT younismohammedt theeffectoflightcuringtimeandintensityonthebondstrengthandfractureresistanceoforthodonticadhesive AT dawoodalaae theeffectoflightcuringtimeandintensityonthebondstrengthandfractureresistanceoforthodonticadhesive AT mohammedomark effectoflightcuringtimeandintensityonthebondstrengthandfractureresistanceoforthodonticadhesive AT younismohammedt effectoflightcuringtimeandintensityonthebondstrengthandfractureresistanceoforthodonticadhesive AT dawoodalaae effectoflightcuringtimeandintensityonthebondstrengthandfractureresistanceoforthodonticadhesive |