Cargando…
NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model
BACKGROUND: The management of bleeding is paramount to any surgical procedure. With the increased use of less invasive laparoscopic and robotic methods, achieving hemostasis can be challenging since the surgeons cannot manually apply hemostatic agents directly onto bleeding tissue. In this study, we...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10463878/ https://www.ncbi.nlm.nih.gov/pubmed/37641071 http://dx.doi.org/10.1186/s12893-023-02159-4 |
_version_ | 1785098335163514880 |
---|---|
author | D’Hondt, Mathieu Roozen, Edwin A. Nuytens, Frederiek Bender, Johan Mottrie, Alexandre Bauwens, Kevin Head, Stuart J. |
author_facet | D’Hondt, Mathieu Roozen, Edwin A. Nuytens, Frederiek Bender, Johan Mottrie, Alexandre Bauwens, Kevin Head, Stuart J. |
author_sort | D’Hondt, Mathieu |
collection | PubMed |
description | BACKGROUND: The management of bleeding is paramount to any surgical procedure. With the increased use of less invasive laparoscopic and robotic methods, achieving hemostasis can be challenging since the surgeons cannot manually apply hemostatic agents directly onto bleeding tissue. In this study, we assessed the use of a pliable hemostatic sealant patch comprising fibrous gelatin carrier impregnated with poly(2-oxazoline) (NHS-POx) for hemostasis in robotic liver resection in a porcine bleeding model. METHODS: The NHS-POx-loaded patch (GATT-Patch), was first evaluated in a Feasibility Study to treat surgical bleeding in 10 lesions, followed by a Comparative Study in which the NHS-POx patch was compared to a standard-of-care fibrin sealant patch (TachoSil), in 36 lesions (superficial, resection, or deep injuries mimicking metastasectomies). For each lesion type, the NHS-POx and fibrin sealant patches were used in an alternating fashion with 18 lesions treated with NHS-POx and 18 with the fibrin patch. Animal preparation and surgical procedures were consistent across studies. The primary outcome was time to hemostasis (TTH) within 3 min for the Feasibility Study and within 5 min for the Comparative Study. RESULTS: In the Feasibility Study, 8 of the 10 NHS-POx-treated lesions achieved hemostasis at 30 s and 3 min. In the Comparative Study, all 18 NHS-POx patch-treated lesions and 9 of the 18 fibrin sealant patch-treated lesions achieved hemostasis at 5 min. Median TTH with NHS-POx vs fibrin sealant patch was 30 vs 300 s (P < 0.001). CONCLUSIONS: In this animal study, hemostasis during robotic liver surgery was achieved faster and more often with the NHS-POx loaded vs fibrin sealant patch. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12893-023-02159-4. |
format | Online Article Text |
id | pubmed-10463878 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-104638782023-08-30 NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model D’Hondt, Mathieu Roozen, Edwin A. Nuytens, Frederiek Bender, Johan Mottrie, Alexandre Bauwens, Kevin Head, Stuart J. BMC Surg Research BACKGROUND: The management of bleeding is paramount to any surgical procedure. With the increased use of less invasive laparoscopic and robotic methods, achieving hemostasis can be challenging since the surgeons cannot manually apply hemostatic agents directly onto bleeding tissue. In this study, we assessed the use of a pliable hemostatic sealant patch comprising fibrous gelatin carrier impregnated with poly(2-oxazoline) (NHS-POx) for hemostasis in robotic liver resection in a porcine bleeding model. METHODS: The NHS-POx-loaded patch (GATT-Patch), was first evaluated in a Feasibility Study to treat surgical bleeding in 10 lesions, followed by a Comparative Study in which the NHS-POx patch was compared to a standard-of-care fibrin sealant patch (TachoSil), in 36 lesions (superficial, resection, or deep injuries mimicking metastasectomies). For each lesion type, the NHS-POx and fibrin sealant patches were used in an alternating fashion with 18 lesions treated with NHS-POx and 18 with the fibrin patch. Animal preparation and surgical procedures were consistent across studies. The primary outcome was time to hemostasis (TTH) within 3 min for the Feasibility Study and within 5 min for the Comparative Study. RESULTS: In the Feasibility Study, 8 of the 10 NHS-POx-treated lesions achieved hemostasis at 30 s and 3 min. In the Comparative Study, all 18 NHS-POx patch-treated lesions and 9 of the 18 fibrin sealant patch-treated lesions achieved hemostasis at 5 min. Median TTH with NHS-POx vs fibrin sealant patch was 30 vs 300 s (P < 0.001). CONCLUSIONS: In this animal study, hemostasis during robotic liver surgery was achieved faster and more often with the NHS-POx loaded vs fibrin sealant patch. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12893-023-02159-4. BioMed Central 2023-08-28 /pmc/articles/PMC10463878/ /pubmed/37641071 http://dx.doi.org/10.1186/s12893-023-02159-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research D’Hondt, Mathieu Roozen, Edwin A. Nuytens, Frederiek Bender, Johan Mottrie, Alexandre Bauwens, Kevin Head, Stuart J. NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model |
title | NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model |
title_full | NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model |
title_fullStr | NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model |
title_full_unstemmed | NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model |
title_short | NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model |
title_sort | nhs-pox-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10463878/ https://www.ncbi.nlm.nih.gov/pubmed/37641071 http://dx.doi.org/10.1186/s12893-023-02159-4 |
work_keys_str_mv | AT dhondtmathieu nhspoxloadedpatchversusfibrinsealantpatchinaporcineroboticliverbleedingmodel AT roozenedwina nhspoxloadedpatchversusfibrinsealantpatchinaporcineroboticliverbleedingmodel AT nuytensfrederiek nhspoxloadedpatchversusfibrinsealantpatchinaporcineroboticliverbleedingmodel AT benderjohan nhspoxloadedpatchversusfibrinsealantpatchinaporcineroboticliverbleedingmodel AT mottriealexandre nhspoxloadedpatchversusfibrinsealantpatchinaporcineroboticliverbleedingmodel AT bauwenskevin nhspoxloadedpatchversusfibrinsealantpatchinaporcineroboticliverbleedingmodel AT headstuartj nhspoxloadedpatchversusfibrinsealantpatchinaporcineroboticliverbleedingmodel |