Cargando…

Modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot

BACKGROUND: Alignment is indispensable for the foot and ankle function, especially in the hindfoot alignment. In the preoperative planning of patients with varus or valgus deformity, the precise measurement of the hindfoot alignment is important. A new method of photographing and measuring hindfoot...

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Jing-Qi, Zhang, Yan, Liu, Liang, Wen, Xiao-Dong, Liu, Pei-Long, Yang, Xin-Quan, Liang, Xiao-Jun, Zhao, Hong-Mou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10464188/
https://www.ncbi.nlm.nih.gov/pubmed/37644473
http://dx.doi.org/10.1186/s12891-023-06824-w
_version_ 1785098411374018560
author Liang, Jing-Qi
Zhang, Yan
Liu, Liang
Wen, Xiao-Dong
Liu, Pei-Long
Yang, Xin-Quan
Liang, Xiao-Jun
Zhao, Hong-Mou
author_facet Liang, Jing-Qi
Zhang, Yan
Liu, Liang
Wen, Xiao-Dong
Liu, Pei-Long
Yang, Xin-Quan
Liang, Xiao-Jun
Zhao, Hong-Mou
author_sort Liang, Jing-Qi
collection PubMed
description BACKGROUND: Alignment is indispensable for the foot and ankle function, especially in the hindfoot alignment. In the preoperative planning of patients with varus or valgus deformity, the precise measurement of the hindfoot alignment is important. A new method of photographing and measuring hindfoot alignment based on X-ray was proposed in this study, and it was applied in the assessment of flatfoot. METHODS: This study included 28 patients (40 feet) with flatfeet and 20 volunteers (40 feet) from January to December 2018. The hindfoot alignment shooting stand independently designed by our department was used to take hindfoot alignment X-rays at 10 degree, 15 degree, 20 degree, 25 degree, and 30 degree. We measured the modified tibio-hindfoot angle (THA) at the standard hindfoot aligment position (shooting at 20 degree) and evaluated consistency with the van Dijk method and the modified van Dijk method. In addition, we observed the visibility of the tibiotalar joint space from all imaging data at five projection angles and evaluated the consistency of the modified THA method at different projection angles. The angle of hindfoot valgus of flatfoot patients was measured using the modified THA method. RESULTS: The mean THA in the standard hindfoot aligment view in normal people was significantly different among the three evaluation methods (P < .001). The results from the modified THA method were significantly larger than those from the Van Dijk method (P < .001) and modified Van Dijk method (P < .001). There was no significant difference between the results of the modified THA method and the weightbearing CT (P = .605), and the intra- and intergroup consistency were the highest in the modified THA group. The tibiotalar space in the normal group was visible in all cases at 10 degree, 15 degree, and 20 degree; visible in some cases at 25 degree; and not visible in all cases at 30 degree. In the flatfoot group, the tibiotalar space was visible in all cases at 10 degree, visible in some cases at 15 degree and 20 degree, and not visible in all cases at 25 degree and 30 degree. In the normal group, the modified THA was 4.84 ± 1.81 degree at 10 degree, 4.96 ± 1.77 degree at 15 degree, and 4.94 ± 2.04 degree at 20 degree. No significant differences were found among the three groups (P = .616). In the flatfoot group, the modified THA of 18 feet, which was visible at 10 degree, 15 degree and 20 degree, was 13.58 ± 3.57 degree at 10 degree, 13.62 ± 3.83 degree at 15 degree and 13.38 ± 4.06 degree at 20 degree. There were no significant differences among the three groups (P = .425). CONCLUSIONS: The modified THA evaluation method is simple to use and has high inter- and intragroup consistency. It can be used to evaluate hindfoot alignment. For patients with flatfeet, the 10 degree position view and modified THA measurement can be used to evaluate hindfoot valgus.
format Online
Article
Text
id pubmed-10464188
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-104641882023-08-30 Modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot Liang, Jing-Qi Zhang, Yan Liu, Liang Wen, Xiao-Dong Liu, Pei-Long Yang, Xin-Quan Liang, Xiao-Jun Zhao, Hong-Mou BMC Musculoskelet Disord Research BACKGROUND: Alignment is indispensable for the foot and ankle function, especially in the hindfoot alignment. In the preoperative planning of patients with varus or valgus deformity, the precise measurement of the hindfoot alignment is important. A new method of photographing and measuring hindfoot alignment based on X-ray was proposed in this study, and it was applied in the assessment of flatfoot. METHODS: This study included 28 patients (40 feet) with flatfeet and 20 volunteers (40 feet) from January to December 2018. The hindfoot alignment shooting stand independently designed by our department was used to take hindfoot alignment X-rays at 10 degree, 15 degree, 20 degree, 25 degree, and 30 degree. We measured the modified tibio-hindfoot angle (THA) at the standard hindfoot aligment position (shooting at 20 degree) and evaluated consistency with the van Dijk method and the modified van Dijk method. In addition, we observed the visibility of the tibiotalar joint space from all imaging data at five projection angles and evaluated the consistency of the modified THA method at different projection angles. The angle of hindfoot valgus of flatfoot patients was measured using the modified THA method. RESULTS: The mean THA in the standard hindfoot aligment view in normal people was significantly different among the three evaluation methods (P < .001). The results from the modified THA method were significantly larger than those from the Van Dijk method (P < .001) and modified Van Dijk method (P < .001). There was no significant difference between the results of the modified THA method and the weightbearing CT (P = .605), and the intra- and intergroup consistency were the highest in the modified THA group. The tibiotalar space in the normal group was visible in all cases at 10 degree, 15 degree, and 20 degree; visible in some cases at 25 degree; and not visible in all cases at 30 degree. In the flatfoot group, the tibiotalar space was visible in all cases at 10 degree, visible in some cases at 15 degree and 20 degree, and not visible in all cases at 25 degree and 30 degree. In the normal group, the modified THA was 4.84 ± 1.81 degree at 10 degree, 4.96 ± 1.77 degree at 15 degree, and 4.94 ± 2.04 degree at 20 degree. No significant differences were found among the three groups (P = .616). In the flatfoot group, the modified THA of 18 feet, which was visible at 10 degree, 15 degree and 20 degree, was 13.58 ± 3.57 degree at 10 degree, 13.62 ± 3.83 degree at 15 degree and 13.38 ± 4.06 degree at 20 degree. There were no significant differences among the three groups (P = .425). CONCLUSIONS: The modified THA evaluation method is simple to use and has high inter- and intragroup consistency. It can be used to evaluate hindfoot alignment. For patients with flatfeet, the 10 degree position view and modified THA measurement can be used to evaluate hindfoot valgus. BioMed Central 2023-08-29 /pmc/articles/PMC10464188/ /pubmed/37644473 http://dx.doi.org/10.1186/s12891-023-06824-w Text en © The Author(s) 2023, corrected publication 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Liang, Jing-Qi
Zhang, Yan
Liu, Liang
Wen, Xiao-Dong
Liu, Pei-Long
Yang, Xin-Quan
Liang, Xiao-Jun
Zhao, Hong-Mou
Modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot
title Modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot
title_full Modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot
title_fullStr Modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot
title_full_unstemmed Modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot
title_short Modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot
title_sort modified hindfoot alignment radiological evaluation and application in the assessment of flatfoot
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10464188/
https://www.ncbi.nlm.nih.gov/pubmed/37644473
http://dx.doi.org/10.1186/s12891-023-06824-w
work_keys_str_mv AT liangjingqi modifiedhindfootalignmentradiologicalevaluationandapplicationintheassessmentofflatfoot
AT zhangyan modifiedhindfootalignmentradiologicalevaluationandapplicationintheassessmentofflatfoot
AT liuliang modifiedhindfootalignmentradiologicalevaluationandapplicationintheassessmentofflatfoot
AT wenxiaodong modifiedhindfootalignmentradiologicalevaluationandapplicationintheassessmentofflatfoot
AT liupeilong modifiedhindfootalignmentradiologicalevaluationandapplicationintheassessmentofflatfoot
AT yangxinquan modifiedhindfootalignmentradiologicalevaluationandapplicationintheassessmentofflatfoot
AT liangxiaojun modifiedhindfootalignmentradiologicalevaluationandapplicationintheassessmentofflatfoot
AT zhaohongmou modifiedhindfootalignmentradiologicalevaluationandapplicationintheassessmentofflatfoot