THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM

OBJECTIVES: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap can le...

Descripción completa

Detalles Bibliográficos
Autores principales: grabowicz, Włodzimierz, Masiarek, Konrad, Górnik, Tomasz, Grycewicz, Tomasz, Brodecki, Marcin, Dabin, Jérémie, Huet, Christelle, Vanhavere, Filip, Domienik-Andrzejewska, Joanna K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nofer Institute of Occupational Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10464785/
https://www.ncbi.nlm.nih.gov/pubmed/35446304
http://dx.doi.org/10.13075/ijomeh.1896.01958
_version_ 1785098541525368832
author grabowicz, Włodzimierz
Masiarek, Konrad
Górnik, Tomasz
Grycewicz, Tomasz
Brodecki, Marcin
Dabin, Jérémie
Huet, Christelle
Vanhavere, Filip
Domienik-Andrzejewska, Joanna K.
author_facet grabowicz, Włodzimierz
Masiarek, Konrad
Górnik, Tomasz
Grycewicz, Tomasz
Brodecki, Marcin
Dabin, Jérémie
Huet, Christelle
Vanhavere, Filip
Domienik-Andrzejewska, Joanna K.
author_sort grabowicz, Włodzimierz
collection PubMed
description OBJECTIVES: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap can lead to ambiguous results, a detailed study was performed. MATERIAL AND METHODS: The effectiveness of a lead free cap in reducing the doses to the skin was assessed in clinic by performing measurements with thermoluminescent dosimeters attached inside and outside the cap first during individual coronary angiography (CA) or CA/percutaneous transluminal coronary angioplasty (CA/PTCA) procedures and then cumulated during few procedures of the same type. In order to investigate the effect of the cap on reducing the doses to the brain additional measurements were performed with a male Alderson Rando and polymethyl methacrylate (PMMA) phantoms representing the physician and the patient, respectively for different projections. The brain dose per procedure, annual and cumulated during entire working practice were estimated for both cases working with and without the cap. RESULTS: The dose reduction factor (RF) for the skin (the quotient of doses outside and inside the cap) vary from 1.1 up to 4.0 in clinical conditions; on average 2.3-fold reduction is observed in the most exposed left temple. The RFs determined for the part of the head covered by the cap range from 1.4 to 1.8 while for the brain from 1.0 to 1.1 depending on the projection. The estimated annual brain dose for interventional cardiologist performing yearly 550 CA/PTCA procedures without any protective shields is 7.2 mGy and it is reduced with the lead free cap by an average factor of 1.1. CONCLUSIONS: The study results proved the considerable effectiveness of lead free cap to protect the skin but very limited to protect the brain. Int J Occup Med Environ Health. 2022;35(5):549 – 60
format Online
Article
Text
id pubmed-10464785
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nofer Institute of Occupational Medicine
record_format MEDLINE/PubMed
spelling pubmed-104647852023-08-29 THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM grabowicz, Włodzimierz Masiarek, Konrad Górnik, Tomasz Grycewicz, Tomasz Brodecki, Marcin Dabin, Jérémie Huet, Christelle Vanhavere, Filip Domienik-Andrzejewska, Joanna K. Int J Occup Med Environ Health Original Paper OBJECTIVES: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap can lead to ambiguous results, a detailed study was performed. MATERIAL AND METHODS: The effectiveness of a lead free cap in reducing the doses to the skin was assessed in clinic by performing measurements with thermoluminescent dosimeters attached inside and outside the cap first during individual coronary angiography (CA) or CA/percutaneous transluminal coronary angioplasty (CA/PTCA) procedures and then cumulated during few procedures of the same type. In order to investigate the effect of the cap on reducing the doses to the brain additional measurements were performed with a male Alderson Rando and polymethyl methacrylate (PMMA) phantoms representing the physician and the patient, respectively for different projections. The brain dose per procedure, annual and cumulated during entire working practice were estimated for both cases working with and without the cap. RESULTS: The dose reduction factor (RF) for the skin (the quotient of doses outside and inside the cap) vary from 1.1 up to 4.0 in clinical conditions; on average 2.3-fold reduction is observed in the most exposed left temple. The RFs determined for the part of the head covered by the cap range from 1.4 to 1.8 while for the brain from 1.0 to 1.1 depending on the projection. The estimated annual brain dose for interventional cardiologist performing yearly 550 CA/PTCA procedures without any protective shields is 7.2 mGy and it is reduced with the lead free cap by an average factor of 1.1. CONCLUSIONS: The study results proved the considerable effectiveness of lead free cap to protect the skin but very limited to protect the brain. Int J Occup Med Environ Health. 2022;35(5):549 – 60 Nofer Institute of Occupational Medicine 2022 2022-09-01 /pmc/articles/PMC10464785/ /pubmed/35446304 http://dx.doi.org/10.13075/ijomeh.1896.01958 Text en © 2006-2022 Journal hosting platform by Bentus https://creativecommons.org/licenses/by-nc/3.0/pl/This work is available in Open Access model and licensed under a Creative Commons Attribution-NonCommercial 3.0 Poland License – http://creativecommons.org/licenses/by-nc/3.0/pl/deed.en (https://creativecommons.org/licenses/by-nc/3.0/pl/) .
spellingShingle Original Paper
grabowicz, Włodzimierz
Masiarek, Konrad
Górnik, Tomasz
Grycewicz, Tomasz
Brodecki, Marcin
Dabin, Jérémie
Huet, Christelle
Vanhavere, Filip
Domienik-Andrzejewska, Joanna K.
THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM
title THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM
title_full THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM
title_fullStr THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM
title_full_unstemmed THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM
title_short THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM
title_sort effect of lead free cap on the doses of ionizing radiation to the head of interventional cardiologists working in haemodynamic room
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10464785/
https://www.ncbi.nlm.nih.gov/pubmed/35446304
http://dx.doi.org/10.13075/ijomeh.1896.01958
work_keys_str_mv AT grabowiczwłodzimierz theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT masiarekkonrad theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT gorniktomasz theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT grycewicztomasz theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT brodeckimarcin theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT dabinjeremie theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT huetchristelle theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT vanhaverefilip theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT domienikandrzejewskajoannak theeffectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT grabowiczwłodzimierz effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT masiarekkonrad effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT gorniktomasz effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT grycewicztomasz effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT brodeckimarcin effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT dabinjeremie effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT huetchristelle effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT vanhaverefilip effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom
AT domienikandrzejewskajoannak effectofleadfreecaponthedosesofionizingradiationtotheheadofinterventionalcardiologistsworkinginhaemodynamicroom