Cargando…
A Vector Fitting Approach for the Automated Estimation of Lumped Boundary Conditions of 1D Circulation Models
PURPOSE: The choice of appropriate boundary conditions is a crucial step in the development of cardiovascular models for blood flow simulations. The three-element Windkessel model is usually employed as a lumped boundary condition, providing a reduced order representation of the peripheral circulati...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10465662/ https://www.ncbi.nlm.nih.gov/pubmed/37308695 http://dx.doi.org/10.1007/s13239-023-00669-z |
_version_ | 1785098720228933632 |
---|---|
author | Fevola, Elisa Bradde, Tommaso Triverio, Piero Grivet-Talocia, Stefano |
author_facet | Fevola, Elisa Bradde, Tommaso Triverio, Piero Grivet-Talocia, Stefano |
author_sort | Fevola, Elisa |
collection | PubMed |
description | PURPOSE: The choice of appropriate boundary conditions is a crucial step in the development of cardiovascular models for blood flow simulations. The three-element Windkessel model is usually employed as a lumped boundary condition, providing a reduced order representation of the peripheral circulation. However, the systematic estimation of the Windkessel parameters remains an open problem. Moreover, the Windkessel model is not always adequate to model blood flow dynamics, which often require more elaborate boundary conditions. In this study, we propose a method for the estimation of the parameters of high order boundary conditions, including the Windkessel model, from pressure and flow rate waveforms at the truncation point. Moreover, we investigate the effect of adopting higher order boundary conditions, corresponding to equivalent circuits with more than one storage element, on the accuracy of the model. METHOD: The proposed technique is based on Time-Domain Vector Fitting, a modeling algorithm that, given samples of the input and output of a system, such as pressure and flow waveforms, can derive a differential equation approximating their relation. RESULTS: The capabilities of the proposed method are tested on a 1D circulation model consisting of the 55 largest human systemic arteries, to demonstrate its accuracy and its usefulness to estimate boundary conditions with order higher than the traditional Windkessel models. The proposed method is compared to other common estimation techniques, and its robustness in parameter estimation is verified in presence of noisy data and of physiological changes of aortic flow rate induced by mental stress. CONCLUSION: Results suggest that the proposed method is able to accurately estimate boundary conditions of arbitrary order. Higher order boundary conditions can improve the accuracy of cardiovascular simulations, and Time-Domain Vector Fitting can automatically estimate them. |
format | Online Article Text |
id | pubmed-10465662 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-104656622023-08-31 A Vector Fitting Approach for the Automated Estimation of Lumped Boundary Conditions of 1D Circulation Models Fevola, Elisa Bradde, Tommaso Triverio, Piero Grivet-Talocia, Stefano Cardiovasc Eng Technol Original Article PURPOSE: The choice of appropriate boundary conditions is a crucial step in the development of cardiovascular models for blood flow simulations. The three-element Windkessel model is usually employed as a lumped boundary condition, providing a reduced order representation of the peripheral circulation. However, the systematic estimation of the Windkessel parameters remains an open problem. Moreover, the Windkessel model is not always adequate to model blood flow dynamics, which often require more elaborate boundary conditions. In this study, we propose a method for the estimation of the parameters of high order boundary conditions, including the Windkessel model, from pressure and flow rate waveforms at the truncation point. Moreover, we investigate the effect of adopting higher order boundary conditions, corresponding to equivalent circuits with more than one storage element, on the accuracy of the model. METHOD: The proposed technique is based on Time-Domain Vector Fitting, a modeling algorithm that, given samples of the input and output of a system, such as pressure and flow waveforms, can derive a differential equation approximating their relation. RESULTS: The capabilities of the proposed method are tested on a 1D circulation model consisting of the 55 largest human systemic arteries, to demonstrate its accuracy and its usefulness to estimate boundary conditions with order higher than the traditional Windkessel models. The proposed method is compared to other common estimation techniques, and its robustness in parameter estimation is verified in presence of noisy data and of physiological changes of aortic flow rate induced by mental stress. CONCLUSION: Results suggest that the proposed method is able to accurately estimate boundary conditions of arbitrary order. Higher order boundary conditions can improve the accuracy of cardiovascular simulations, and Time-Domain Vector Fitting can automatically estimate them. Springer International Publishing 2023-06-12 2023 /pmc/articles/PMC10465662/ /pubmed/37308695 http://dx.doi.org/10.1007/s13239-023-00669-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Fevola, Elisa Bradde, Tommaso Triverio, Piero Grivet-Talocia, Stefano A Vector Fitting Approach for the Automated Estimation of Lumped Boundary Conditions of 1D Circulation Models |
title | A Vector Fitting Approach for the Automated Estimation of Lumped Boundary Conditions of 1D Circulation Models |
title_full | A Vector Fitting Approach for the Automated Estimation of Lumped Boundary Conditions of 1D Circulation Models |
title_fullStr | A Vector Fitting Approach for the Automated Estimation of Lumped Boundary Conditions of 1D Circulation Models |
title_full_unstemmed | A Vector Fitting Approach for the Automated Estimation of Lumped Boundary Conditions of 1D Circulation Models |
title_short | A Vector Fitting Approach for the Automated Estimation of Lumped Boundary Conditions of 1D Circulation Models |
title_sort | vector fitting approach for the automated estimation of lumped boundary conditions of 1d circulation models |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10465662/ https://www.ncbi.nlm.nih.gov/pubmed/37308695 http://dx.doi.org/10.1007/s13239-023-00669-z |
work_keys_str_mv | AT fevolaelisa avectorfittingapproachfortheautomatedestimationoflumpedboundaryconditionsof1dcirculationmodels AT braddetommaso avectorfittingapproachfortheautomatedestimationoflumpedboundaryconditionsof1dcirculationmodels AT triveriopiero avectorfittingapproachfortheautomatedestimationoflumpedboundaryconditionsof1dcirculationmodels AT grivettalociastefano avectorfittingapproachfortheautomatedestimationoflumpedboundaryconditionsof1dcirculationmodels AT fevolaelisa vectorfittingapproachfortheautomatedestimationoflumpedboundaryconditionsof1dcirculationmodels AT braddetommaso vectorfittingapproachfortheautomatedestimationoflumpedboundaryconditionsof1dcirculationmodels AT triveriopiero vectorfittingapproachfortheautomatedestimationoflumpedboundaryconditionsof1dcirculationmodels AT grivettalociastefano vectorfittingapproachfortheautomatedestimationoflumpedboundaryconditionsof1dcirculationmodels |