Cargando…

Multiple Methods of Dentin Translucency for Age Estimation

BACKGROUND: Age estimation is an essential part of forensic odontology and many methods are available with variable accuracy. However, the research is going on to find the simple and most reliable method. OBJECTIVES: By measuring the length and area of root dentin translucency in extracted tooth spe...

Descripción completa

Detalles Bibliográficos
Autores principales: Soorneedi, Neeharika, Venkatachalaiah, Ashok, Manikya, Sangameshwar, Dasari, Ankineedu Babu, Gaddam, Bhavyasri, Latha, Aparna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10466666/
https://www.ncbi.nlm.nih.gov/pubmed/37654306
http://dx.doi.org/10.4103/jpbs.jpbs_33_23
_version_ 1785098937362808832
author Soorneedi, Neeharika
Venkatachalaiah, Ashok
Manikya, Sangameshwar
Dasari, Ankineedu Babu
Gaddam, Bhavyasri
Latha, Aparna
author_facet Soorneedi, Neeharika
Venkatachalaiah, Ashok
Manikya, Sangameshwar
Dasari, Ankineedu Babu
Gaddam, Bhavyasri
Latha, Aparna
author_sort Soorneedi, Neeharika
collection PubMed
description BACKGROUND: Age estimation is an essential part of forensic odontology and many methods are available with variable accuracy. However, the research is going on to find the simple and most reliable method. OBJECTIVES: By measuring the length and area of root dentin translucency in extracted tooth specimens manually and digitally, and comparing them, this study aims to find the most reliable technique of age assessment. MATERIALS AND METHODS: One-hundred and twenty-five single-rooted extracted human permanent teeth were selected for the study. In both unsectioned and sectioned teeth, the total length of root dentin translucency was manually measured using a digital vernier caliper. Then, in a ground-sectioned tooth specimen, the total length and area of root dentin translucency were measured digitally using a scanner scale and computer software. Both the methods were compared. RESULTS: In both manual and digital approaches, the length and area of root dentin translucency grew with age, from younger to older age groups. On comparing the measurements, the correlation coefficient was somewhat higher for digital area measurements than other measurements (r = 0.985). CONCLUSION: The digital technique outperforms the traditional way for calculating age, and furthermore, measuring the area in the digital method for age estimation has shown to be more accurate.
format Online
Article
Text
id pubmed-10466666
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-104666662023-08-31 Multiple Methods of Dentin Translucency for Age Estimation Soorneedi, Neeharika Venkatachalaiah, Ashok Manikya, Sangameshwar Dasari, Ankineedu Babu Gaddam, Bhavyasri Latha, Aparna J Pharm Bioallied Sci Original Article BACKGROUND: Age estimation is an essential part of forensic odontology and many methods are available with variable accuracy. However, the research is going on to find the simple and most reliable method. OBJECTIVES: By measuring the length and area of root dentin translucency in extracted tooth specimens manually and digitally, and comparing them, this study aims to find the most reliable technique of age assessment. MATERIALS AND METHODS: One-hundred and twenty-five single-rooted extracted human permanent teeth were selected for the study. In both unsectioned and sectioned teeth, the total length of root dentin translucency was manually measured using a digital vernier caliper. Then, in a ground-sectioned tooth specimen, the total length and area of root dentin translucency were measured digitally using a scanner scale and computer software. Both the methods were compared. RESULTS: In both manual and digital approaches, the length and area of root dentin translucency grew with age, from younger to older age groups. On comparing the measurements, the correlation coefficient was somewhat higher for digital area measurements than other measurements (r = 0.985). CONCLUSION: The digital technique outperforms the traditional way for calculating age, and furthermore, measuring the area in the digital method for age estimation has shown to be more accurate. Wolters Kluwer - Medknow 2023-07 2023-07-05 /pmc/articles/PMC10466666/ /pubmed/37654306 http://dx.doi.org/10.4103/jpbs.jpbs_33_23 Text en Copyright: © 2023 Journal of Pharmacy and Bioallied Sciences https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Soorneedi, Neeharika
Venkatachalaiah, Ashok
Manikya, Sangameshwar
Dasari, Ankineedu Babu
Gaddam, Bhavyasri
Latha, Aparna
Multiple Methods of Dentin Translucency for Age Estimation
title Multiple Methods of Dentin Translucency for Age Estimation
title_full Multiple Methods of Dentin Translucency for Age Estimation
title_fullStr Multiple Methods of Dentin Translucency for Age Estimation
title_full_unstemmed Multiple Methods of Dentin Translucency for Age Estimation
title_short Multiple Methods of Dentin Translucency for Age Estimation
title_sort multiple methods of dentin translucency for age estimation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10466666/
https://www.ncbi.nlm.nih.gov/pubmed/37654306
http://dx.doi.org/10.4103/jpbs.jpbs_33_23
work_keys_str_mv AT soorneedineeharika multiplemethodsofdentintranslucencyforageestimation
AT venkatachalaiahashok multiplemethodsofdentintranslucencyforageestimation
AT manikyasangameshwar multiplemethodsofdentintranslucencyforageestimation
AT dasariankineedubabu multiplemethodsofdentintranslucencyforageestimation
AT gaddambhavyasri multiplemethodsofdentintranslucencyforageestimation
AT lathaaparna multiplemethodsofdentintranslucencyforageestimation