Virtual Treatment Zone From Cone Beam CT Commonly Alters Treatment Plan and Identifies Tumor at Risk for Under-Treatment in US or US Fusion-Guided Microwave Ablation of Liver Tumors

Tumor ablation is included in several major cancer therapy guidelines. One technical challenge of percutaneous ablation is targeting and verification of complete treatment, which is prone to operator variabilities and human imperfections and are directly related to successful outcomes, risk for resi...

Descripción completa

Detalles Bibliográficos
Autores principales: Arrichiello, Antonio, Ierardi, Anna Maria, Caruso, Alessandro, Grillo, Pasquale, Di Meglio, Letizia, Biondetti, Pierpaolo, Iavarone, Massimo, Sangiovanni, Angelo, Angileri, Salvatore Alessio, Floridi, Chiara, Wood, Bradford, Carrafiello, Gianpaolo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10467384/
https://www.ncbi.nlm.nih.gov/pubmed/37608564
http://dx.doi.org/10.1177/15330338231181284
_version_ 1785099099467415552
author Arrichiello, Antonio
Ierardi, Anna Maria
Caruso, Alessandro
Grillo, Pasquale
Di Meglio, Letizia
Biondetti, Pierpaolo
Iavarone, Massimo
Sangiovanni, Angelo
Angileri, Salvatore Alessio
Floridi, Chiara
Wood, Bradford
Carrafiello, Gianpaolo
author_facet Arrichiello, Antonio
Ierardi, Anna Maria
Caruso, Alessandro
Grillo, Pasquale
Di Meglio, Letizia
Biondetti, Pierpaolo
Iavarone, Massimo
Sangiovanni, Angelo
Angileri, Salvatore Alessio
Floridi, Chiara
Wood, Bradford
Carrafiello, Gianpaolo
author_sort Arrichiello, Antonio
collection PubMed
description Tumor ablation is included in several major cancer therapy guidelines. One technical challenge of percutaneous ablation is targeting and verification of complete treatment, which is prone to operator variabilities and human imperfections and are directly related to successful outcomes, risk for residual unablated tumor and local progression. The use of “Prediction Ablation Volume Software” may help the operating Interventional Radiologist to better plan, deliver, and verify before the ablation, via virtual treatment zones fused to target tumor. Fused and superimposed images provide 3-dimensional information from different timepoints, just when that information is most useful. The aim of this study is to evaluate the technical success and efficacy of an ablation treatment flowchart provided by a cone beam computed tomography (CBCT) “Prediction Ablation Volume Software.” This is a single-center retrospective study. From April 2021 to January 2022, 29 nonconsecutive evaluable patients with 32 lesions underwent liver ablation with Prediction Ablation Volume Software. Each patient was discussed in a multidisciplinary tumor board and underwent an enhanced computed tomography or magnetic resonance imaging approximately 1 month before the procedure, as well as ∼1 month after. Technical success was defined as treatment of the tumor according to the protocol, covered completely by the Prediction Ablation Volume. Technical efficacy was defined as assessment of complete ablation of the target tumor at imaging follow up (∼1 month). Technical success, technical efficacy, and procedural factors were studied. Technical success was achieved in 30 of 32 liver lesions (94%), measuring 20 mm mean maximum diameter. The antenna was repositioned in 16 of 30 (53%) evaluable target lesions. Residual tumor was detected at 1 month imaging follow up in only 4 of 30 (13%) of the treated lesion. Technical efficacy was of 87% in this retrospective description of our process. The implementation of a CBCT Prediction Ablation Volume Software and flowchart for the treatment of liver malignancies altered the procedure, and demonstrated high technical success and efficacy. Such tools are potentially useful for procedural prediction and verification of ablation.
format Online
Article
Text
id pubmed-10467384
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-104673842023-08-31 Virtual Treatment Zone From Cone Beam CT Commonly Alters Treatment Plan and Identifies Tumor at Risk for Under-Treatment in US or US Fusion-Guided Microwave Ablation of Liver Tumors Arrichiello, Antonio Ierardi, Anna Maria Caruso, Alessandro Grillo, Pasquale Di Meglio, Letizia Biondetti, Pierpaolo Iavarone, Massimo Sangiovanni, Angelo Angileri, Salvatore Alessio Floridi, Chiara Wood, Bradford Carrafiello, Gianpaolo Technol Cancer Res Treat New tools in loco-regional treatments: state of art and future directions Tumor ablation is included in several major cancer therapy guidelines. One technical challenge of percutaneous ablation is targeting and verification of complete treatment, which is prone to operator variabilities and human imperfections and are directly related to successful outcomes, risk for residual unablated tumor and local progression. The use of “Prediction Ablation Volume Software” may help the operating Interventional Radiologist to better plan, deliver, and verify before the ablation, via virtual treatment zones fused to target tumor. Fused and superimposed images provide 3-dimensional information from different timepoints, just when that information is most useful. The aim of this study is to evaluate the technical success and efficacy of an ablation treatment flowchart provided by a cone beam computed tomography (CBCT) “Prediction Ablation Volume Software.” This is a single-center retrospective study. From April 2021 to January 2022, 29 nonconsecutive evaluable patients with 32 lesions underwent liver ablation with Prediction Ablation Volume Software. Each patient was discussed in a multidisciplinary tumor board and underwent an enhanced computed tomography or magnetic resonance imaging approximately 1 month before the procedure, as well as ∼1 month after. Technical success was defined as treatment of the tumor according to the protocol, covered completely by the Prediction Ablation Volume. Technical efficacy was defined as assessment of complete ablation of the target tumor at imaging follow up (∼1 month). Technical success, technical efficacy, and procedural factors were studied. Technical success was achieved in 30 of 32 liver lesions (94%), measuring 20 mm mean maximum diameter. The antenna was repositioned in 16 of 30 (53%) evaluable target lesions. Residual tumor was detected at 1 month imaging follow up in only 4 of 30 (13%) of the treated lesion. Technical efficacy was of 87% in this retrospective description of our process. The implementation of a CBCT Prediction Ablation Volume Software and flowchart for the treatment of liver malignancies altered the procedure, and demonstrated high technical success and efficacy. Such tools are potentially useful for procedural prediction and verification of ablation. SAGE Publications 2023-08-22 /pmc/articles/PMC10467384/ /pubmed/37608564 http://dx.doi.org/10.1177/15330338231181284 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle New tools in loco-regional treatments: state of art and future directions
Arrichiello, Antonio
Ierardi, Anna Maria
Caruso, Alessandro
Grillo, Pasquale
Di Meglio, Letizia
Biondetti, Pierpaolo
Iavarone, Massimo
Sangiovanni, Angelo
Angileri, Salvatore Alessio
Floridi, Chiara
Wood, Bradford
Carrafiello, Gianpaolo
Virtual Treatment Zone From Cone Beam CT Commonly Alters Treatment Plan and Identifies Tumor at Risk for Under-Treatment in US or US Fusion-Guided Microwave Ablation of Liver Tumors
title Virtual Treatment Zone From Cone Beam CT Commonly Alters Treatment Plan and Identifies Tumor at Risk for Under-Treatment in US or US Fusion-Guided Microwave Ablation of Liver Tumors
title_full Virtual Treatment Zone From Cone Beam CT Commonly Alters Treatment Plan and Identifies Tumor at Risk for Under-Treatment in US or US Fusion-Guided Microwave Ablation of Liver Tumors
title_fullStr Virtual Treatment Zone From Cone Beam CT Commonly Alters Treatment Plan and Identifies Tumor at Risk for Under-Treatment in US or US Fusion-Guided Microwave Ablation of Liver Tumors
title_full_unstemmed Virtual Treatment Zone From Cone Beam CT Commonly Alters Treatment Plan and Identifies Tumor at Risk for Under-Treatment in US or US Fusion-Guided Microwave Ablation of Liver Tumors
title_short Virtual Treatment Zone From Cone Beam CT Commonly Alters Treatment Plan and Identifies Tumor at Risk for Under-Treatment in US or US Fusion-Guided Microwave Ablation of Liver Tumors
title_sort virtual treatment zone from cone beam ct commonly alters treatment plan and identifies tumor at risk for under-treatment in us or us fusion-guided microwave ablation of liver tumors
topic New tools in loco-regional treatments: state of art and future directions
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10467384/
https://www.ncbi.nlm.nih.gov/pubmed/37608564
http://dx.doi.org/10.1177/15330338231181284
work_keys_str_mv AT arrichielloantonio virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT ierardiannamaria virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT carusoalessandro virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT grillopasquale virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT dimeglioletizia virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT biondettipierpaolo virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT iavaronemassimo virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT sangiovanniangelo virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT angilerisalvatorealessio virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT floridichiara virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT woodbradford virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors
AT carrafiellogianpaolo virtualtreatmentzonefromconebeamctcommonlyalterstreatmentplanandidentifiestumoratriskforundertreatmentinusorusfusionguidedmicrowaveablationoflivertumors