Cargando…

Biomechanical Analysis Evaluating Meniscal Extrusion After Knotless Suture Anchor Fixation for Segmental Medial Meniscal Allograft Transplantation

BACKGROUND: Segmental medial meniscal allograft transplantation (MAT) has been shown to restore knee biomechanics; however, stable fixation of the transplantation is critical to avoid extrusion and maximize healing. PURPOSE: To evaluate the degree of meniscal extrusion and biomechanical function of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ganokroj, Phob, Fossum, Bradley W., Hollenbeck, Justin, Whalen, Ryan J., Garcia, Alexander R., Foster, Michael J., Provencher, CAPT Matthew T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10467413/
https://www.ncbi.nlm.nih.gov/pubmed/37655248
http://dx.doi.org/10.1177/23259671231182978
_version_ 1785099107635822592
author Ganokroj, Phob
Fossum, Bradley W.
Hollenbeck, Justin
Whalen, Ryan J.
Garcia, Alexander R.
Foster, Michael J.
Provencher, CAPT Matthew T.
author_facet Ganokroj, Phob
Fossum, Bradley W.
Hollenbeck, Justin
Whalen, Ryan J.
Garcia, Alexander R.
Foster, Michael J.
Provencher, CAPT Matthew T.
author_sort Ganokroj, Phob
collection PubMed
description BACKGROUND: Segmental medial meniscal allograft transplantation (MAT) has been shown to restore knee biomechanics; however, stable fixation of the transplantation is critical to avoid extrusion and maximize healing. PURPOSE: To evaluate the degree of meniscal extrusion and biomechanical function of segmental medial MAT performed with meniscocapsular sutures versus repair augmentation with knotless suture anchors. STUDY DESIGN: Controlled laboratory study. METHODS: Segmental midbody medial meniscectomy and subsequent segmental medial MAT were performed on 10 fresh-frozen cadaveric knees. The knees were then loaded in a dynamic tensile testing machine to 1000 N for 60 seconds at 0°, 30°, 60°, and 90° of flexion, and 4 conditions were tested: (1) intact, (2) segmental defect, (3) inside-out segmental repair, and (4) anchor plus inside-out segmental repair of the medial MAT. Meniscal extrusion was measured using high-fidelity ultrasound imaging. The mean contact area and the mean and peak contact pressures were assessed with submeniscal pressure-mapping sensors. Data from testing conditions were compared with 2-way repeated-measures analysis of variance, with pairwise comparison using the Bonferroni method. RESULTS: At 90° of flexion, the segmental defect state showed a higher degree of meniscal extrusion compared with all other states (P ≤ .012). There was no difference in the degree of meniscal extrusion between the intact state and the inside-out repair or anchor plus inside-out segmental repair states at all knee flexion angles (P > .05). There was no significant difference in the mean and peak contact pressures among the 4 states at all flexion angles except that at 0° of knee flexion there was significantly lower peak contact pressure at the medial compartment after anchor plus inside-out segmental repair compared with the segmental defect state (P = .048). CONCLUSION: Meniscal extrusion was not significantly increased at any flexion angle after segmental resection. The addition of knotless anchors did not improve meniscal extrusion or contact pressures/area compared with capsular repair alone. The addition of knotless anchors did improve contact mechanics from the segmental defect state, but only at 0° of flexion. CLINICAL RELEVANCE: The addition of knotless suture anchors to segmental meniscal transplantation increased stabilization of the meniscus at full extension compared with repair with sutures alone. This increased stabilization may lead to better long-term outcomes.
format Online
Article
Text
id pubmed-10467413
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-104674132023-08-31 Biomechanical Analysis Evaluating Meniscal Extrusion After Knotless Suture Anchor Fixation for Segmental Medial Meniscal Allograft Transplantation Ganokroj, Phob Fossum, Bradley W. Hollenbeck, Justin Whalen, Ryan J. Garcia, Alexander R. Foster, Michael J. Provencher, CAPT Matthew T. Orthop J Sports Med Article BACKGROUND: Segmental medial meniscal allograft transplantation (MAT) has been shown to restore knee biomechanics; however, stable fixation of the transplantation is critical to avoid extrusion and maximize healing. PURPOSE: To evaluate the degree of meniscal extrusion and biomechanical function of segmental medial MAT performed with meniscocapsular sutures versus repair augmentation with knotless suture anchors. STUDY DESIGN: Controlled laboratory study. METHODS: Segmental midbody medial meniscectomy and subsequent segmental medial MAT were performed on 10 fresh-frozen cadaveric knees. The knees were then loaded in a dynamic tensile testing machine to 1000 N for 60 seconds at 0°, 30°, 60°, and 90° of flexion, and 4 conditions were tested: (1) intact, (2) segmental defect, (3) inside-out segmental repair, and (4) anchor plus inside-out segmental repair of the medial MAT. Meniscal extrusion was measured using high-fidelity ultrasound imaging. The mean contact area and the mean and peak contact pressures were assessed with submeniscal pressure-mapping sensors. Data from testing conditions were compared with 2-way repeated-measures analysis of variance, with pairwise comparison using the Bonferroni method. RESULTS: At 90° of flexion, the segmental defect state showed a higher degree of meniscal extrusion compared with all other states (P ≤ .012). There was no difference in the degree of meniscal extrusion between the intact state and the inside-out repair or anchor plus inside-out segmental repair states at all knee flexion angles (P > .05). There was no significant difference in the mean and peak contact pressures among the 4 states at all flexion angles except that at 0° of knee flexion there was significantly lower peak contact pressure at the medial compartment after anchor plus inside-out segmental repair compared with the segmental defect state (P = .048). CONCLUSION: Meniscal extrusion was not significantly increased at any flexion angle after segmental resection. The addition of knotless anchors did not improve meniscal extrusion or contact pressures/area compared with capsular repair alone. The addition of knotless anchors did improve contact mechanics from the segmental defect state, but only at 0° of flexion. CLINICAL RELEVANCE: The addition of knotless suture anchors to segmental meniscal transplantation increased stabilization of the meniscus at full extension compared with repair with sutures alone. This increased stabilization may lead to better long-term outcomes. SAGE Publications 2023-08-22 /pmc/articles/PMC10467413/ /pubmed/37655248 http://dx.doi.org/10.1177/23259671231182978 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Ganokroj, Phob
Fossum, Bradley W.
Hollenbeck, Justin
Whalen, Ryan J.
Garcia, Alexander R.
Foster, Michael J.
Provencher, CAPT Matthew T.
Biomechanical Analysis Evaluating Meniscal Extrusion After Knotless Suture Anchor Fixation for Segmental Medial Meniscal Allograft Transplantation
title Biomechanical Analysis Evaluating Meniscal Extrusion After Knotless Suture Anchor Fixation for Segmental Medial Meniscal Allograft Transplantation
title_full Biomechanical Analysis Evaluating Meniscal Extrusion After Knotless Suture Anchor Fixation for Segmental Medial Meniscal Allograft Transplantation
title_fullStr Biomechanical Analysis Evaluating Meniscal Extrusion After Knotless Suture Anchor Fixation for Segmental Medial Meniscal Allograft Transplantation
title_full_unstemmed Biomechanical Analysis Evaluating Meniscal Extrusion After Knotless Suture Anchor Fixation for Segmental Medial Meniscal Allograft Transplantation
title_short Biomechanical Analysis Evaluating Meniscal Extrusion After Knotless Suture Anchor Fixation for Segmental Medial Meniscal Allograft Transplantation
title_sort biomechanical analysis evaluating meniscal extrusion after knotless suture anchor fixation for segmental medial meniscal allograft transplantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10467413/
https://www.ncbi.nlm.nih.gov/pubmed/37655248
http://dx.doi.org/10.1177/23259671231182978
work_keys_str_mv AT ganokrojphob biomechanicalanalysisevaluatingmeniscalextrusionafterknotlesssutureanchorfixationforsegmentalmedialmeniscalallografttransplantation
AT fossumbradleyw biomechanicalanalysisevaluatingmeniscalextrusionafterknotlesssutureanchorfixationforsegmentalmedialmeniscalallografttransplantation
AT hollenbeckjustin biomechanicalanalysisevaluatingmeniscalextrusionafterknotlesssutureanchorfixationforsegmentalmedialmeniscalallografttransplantation
AT whalenryanj biomechanicalanalysisevaluatingmeniscalextrusionafterknotlesssutureanchorfixationforsegmentalmedialmeniscalallografttransplantation
AT garciaalexanderr biomechanicalanalysisevaluatingmeniscalextrusionafterknotlesssutureanchorfixationforsegmentalmedialmeniscalallografttransplantation
AT fostermichaelj biomechanicalanalysisevaluatingmeniscalextrusionafterknotlesssutureanchorfixationforsegmentalmedialmeniscalallografttransplantation
AT provenchercaptmatthewt biomechanicalanalysisevaluatingmeniscalextrusionafterknotlesssutureanchorfixationforsegmentalmedialmeniscalallografttransplantation