Cargando…
Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis
BACKGROUND: Zero-profile anchored spacers (ZAS) and plate-cage constructs (PCC) are currently employed when performing anterior cervical discectomy and fusion (ACDF). Nevertheless, the efficacy and safety of both devices in bilevel ACDF remain controversial. The goal of our meta-analysis is to asses...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10469803/ https://www.ncbi.nlm.nih.gov/pubmed/37653510 http://dx.doi.org/10.1186/s13018-023-04134-4 |
_version_ | 1785099526949830656 |
---|---|
author | Zhang, Yu Ju, Jidong Wu, Jinchun |
author_facet | Zhang, Yu Ju, Jidong Wu, Jinchun |
author_sort | Zhang, Yu |
collection | PubMed |
description | BACKGROUND: Zero-profile anchored spacers (ZAS) and plate-cage constructs (PCC) are currently employed when performing anterior cervical discectomy and fusion (ACDF). Nevertheless, the efficacy and safety of both devices in bilevel ACDF remain controversial. The goal of our meta-analysis is to assess the overall long-term efficacy and security among ZAS and PCC in bilevel ACDF. METHODS: A search of four electronic databases was conducted to identify researches that compared ZAS with PCC for bilevel ACDF. Stata MP 17.0 software was used for this meta-analysis. RESULTS: Nine researches with a total of 580 patients were involved. In comparison to PCC, ZAS significantly reduced intraoperative bleeding and postoperative dysphagia rates. No significant differences were found concerning operation time, JOA score, NDI score, cervical Cobb angle, fusion rates, the incidence of adjacent segmental degeneration (ASD) and implant sinking rates at last follow-up. CONCLUSION: Compared to PCC, ZAS achieved similar efficacy and security in bilevel ACDF with respect to operative time, JOA score, NDI score, cervical Cobb angle, fusion rates, implant sinking rates and ASD rates at final follow-up. It is worth noting that ZAS offered considerable benefits over conventional PCC for the reduction of intraoperative bleeding and postoperative dysphagia. Therefore, for patients requiring bilevel ACDF, ZAS seems superior to PCC. Given the limitations of our study, larger prospective randomised controlled trials are needed to establish reliable proof to consolidate our conclusions. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13018-023-04134-4. |
format | Online Article Text |
id | pubmed-10469803 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-104698032023-09-01 Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis Zhang, Yu Ju, Jidong Wu, Jinchun J Orthop Surg Res Systematic Review BACKGROUND: Zero-profile anchored spacers (ZAS) and plate-cage constructs (PCC) are currently employed when performing anterior cervical discectomy and fusion (ACDF). Nevertheless, the efficacy and safety of both devices in bilevel ACDF remain controversial. The goal of our meta-analysis is to assess the overall long-term efficacy and security among ZAS and PCC in bilevel ACDF. METHODS: A search of four electronic databases was conducted to identify researches that compared ZAS with PCC for bilevel ACDF. Stata MP 17.0 software was used for this meta-analysis. RESULTS: Nine researches with a total of 580 patients were involved. In comparison to PCC, ZAS significantly reduced intraoperative bleeding and postoperative dysphagia rates. No significant differences were found concerning operation time, JOA score, NDI score, cervical Cobb angle, fusion rates, the incidence of adjacent segmental degeneration (ASD) and implant sinking rates at last follow-up. CONCLUSION: Compared to PCC, ZAS achieved similar efficacy and security in bilevel ACDF with respect to operative time, JOA score, NDI score, cervical Cobb angle, fusion rates, implant sinking rates and ASD rates at final follow-up. It is worth noting that ZAS offered considerable benefits over conventional PCC for the reduction of intraoperative bleeding and postoperative dysphagia. Therefore, for patients requiring bilevel ACDF, ZAS seems superior to PCC. Given the limitations of our study, larger prospective randomised controlled trials are needed to establish reliable proof to consolidate our conclusions. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13018-023-04134-4. BioMed Central 2023-08-31 /pmc/articles/PMC10469803/ /pubmed/37653510 http://dx.doi.org/10.1186/s13018-023-04134-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Systematic Review Zhang, Yu Ju, Jidong Wu, Jinchun Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis |
title | Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis |
title_full | Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis |
title_fullStr | Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis |
title_full_unstemmed | Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis |
title_short | Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis |
title_sort | zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10469803/ https://www.ncbi.nlm.nih.gov/pubmed/37653510 http://dx.doi.org/10.1186/s13018-023-04134-4 |
work_keys_str_mv | AT zhangyu zeroprofileanchoredspacerversusconventionalplatecageconstructinbilevelanteriorcervicaldiscectomyandfusionasystematicreviewandmetaanalysis AT jujidong zeroprofileanchoredspacerversusconventionalplatecageconstructinbilevelanteriorcervicaldiscectomyandfusionasystematicreviewandmetaanalysis AT wujinchun zeroprofileanchoredspacerversusconventionalplatecageconstructinbilevelanteriorcervicaldiscectomyandfusionasystematicreviewandmetaanalysis |