Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures
PURPOSE: This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10471504/ https://www.ncbi.nlm.nih.gov/pubmed/37662854 http://dx.doi.org/10.4047/jap.2023.15.4.214 |
_version_ | 1785099864360615936 |
---|---|
author | Avukat, Esra Nur Akay, Canan Mumcu, Emre |
author_facet | Avukat, Esra Nur Akay, Canan Mumcu, Emre |
author_sort | Avukat, Esra Nur |
collection | PubMed |
description | PURPOSE: This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. MATERIALS AND METHODS: A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. RESULTS: It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. CONCLUSION: Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction. |
format | Online Article Text |
id | pubmed-10471504 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-104715042023-09-02 Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures Avukat, Esra Nur Akay, Canan Mumcu, Emre J Adv Prosthodont Original Article PURPOSE: This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. MATERIALS AND METHODS: A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. RESULTS: It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. CONCLUSION: Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction. The Korean Academy of Prosthodontics 2023-08 2023-08-28 /pmc/articles/PMC10471504/ /pubmed/37662854 http://dx.doi.org/10.4047/jap.2023.15.4.214 Text en © 2023 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Avukat, Esra Nur Akay, Canan Mumcu, Emre Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures |
title | Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures |
title_full | Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures |
title_fullStr | Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures |
title_full_unstemmed | Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures |
title_short | Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures |
title_sort | evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10471504/ https://www.ncbi.nlm.nih.gov/pubmed/37662854 http://dx.doi.org/10.4047/jap.2023.15.4.214 |
work_keys_str_mv | AT avukatesranur evaluationofbiteforcequalityoflifeandpatientssatisfactioninelderlyedentulouspatientsusingimplantoverdentures AT akaycanan evaluationofbiteforcequalityoflifeandpatientssatisfactioninelderlyedentulouspatientsusingimplantoverdentures AT mumcuemre evaluationofbiteforcequalityoflifeandpatientssatisfactioninelderlyedentulouspatientsusingimplantoverdentures |