Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions
PURPOSE: This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS: A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10471506/ https://www.ncbi.nlm.nih.gov/pubmed/37662853 http://dx.doi.org/10.4047/jap.2023.15.4.179 |
_version_ | 1785099864823037952 |
---|---|
author | Akkal, Ozcan Korkmaz, Ismail Hakki Bayindir, Funda |
author_facet | Akkal, Ozcan Korkmaz, Ismail Hakki Bayindir, Funda |
author_sort | Akkal, Ozcan |
collection | PubMed |
description | PURPOSE: This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS: A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS: While the Primescan (PS) impression group had the highest accuracy with 38 µm, the values of 104 µm and 171 µm were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively (P = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners (P < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values (P > .05). CONCLUSION: A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group. |
format | Online Article Text |
id | pubmed-10471506 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-104715062023-09-02 Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions Akkal, Ozcan Korkmaz, Ismail Hakki Bayindir, Funda J Adv Prosthodont Original Article PURPOSE: This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS: A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS: While the Primescan (PS) impression group had the highest accuracy with 38 µm, the values of 104 µm and 171 µm were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively (P = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners (P < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values (P > .05). CONCLUSION: A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group. The Korean Academy of Prosthodontics 2023-08 2023-08-28 /pmc/articles/PMC10471506/ /pubmed/37662853 http://dx.doi.org/10.4047/jap.2023.15.4.179 Text en © 2023 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Akkal, Ozcan Korkmaz, Ismail Hakki Bayindir, Funda Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions |
title | Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions |
title_full | Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions |
title_fullStr | Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions |
title_full_unstemmed | Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions |
title_short | Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions |
title_sort | comparison of 3d accuracy of three different digital intraoral scanners in full-arch implant impressions |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10471506/ https://www.ncbi.nlm.nih.gov/pubmed/37662853 http://dx.doi.org/10.4047/jap.2023.15.4.179 |
work_keys_str_mv | AT akkalozcan comparisonof3daccuracyofthreedifferentdigitalintraoralscannersinfullarchimplantimpressions AT korkmazismailhakki comparisonof3daccuracyofthreedifferentdigitalintraoralscannersinfullarchimplantimpressions AT bayindirfunda comparisonof3daccuracyofthreedifferentdigitalintraoralscannersinfullarchimplantimpressions |