Cargando…

The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study

BACKGROUND: CAD/CAM has considerably transformed the clinical practice of dentistry. In particular, advanced dental materials produced via digital technologies offer unquestionable benefits, such as ideal mechanical stability, outstanding aesthetics and reliable high precision. Additive manufacturin...

Descripción completa

Detalles Bibliográficos
Autores principales: Othman, Ahmed, Sandmair, Maximillian, Alevizakos, Vasilios, von See, Constantin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10473469/
https://www.ncbi.nlm.nih.gov/pubmed/37656728
http://dx.doi.org/10.1371/journal.pone.0285760
_version_ 1785100279791747072
author Othman, Ahmed
Sandmair, Maximillian
Alevizakos, Vasilios
von See, Constantin
author_facet Othman, Ahmed
Sandmair, Maximillian
Alevizakos, Vasilios
von See, Constantin
author_sort Othman, Ahmed
collection PubMed
description BACKGROUND: CAD/CAM has considerably transformed the clinical practice of dentistry. In particular, advanced dental materials produced via digital technologies offer unquestionable benefits, such as ideal mechanical stability, outstanding aesthetics and reliable high precision. Additive manufacturing (AM) technology has promoted new innovations, especially in the field of biomedicine. AIMS: The aim of this study is to analyze the fracture resistance of implant-supported 3D-printed temporary crowns relative to milled crowns by compression testing. METHODS: The study sample included 32 specimens of temporary crowns, which were divided into 16 specimens per group. Each group consisted of eight maxillary central incisor crowns (tooth 11) and eight maxillary molar crowns (tooth 16). The first group (16 specimens) was 3D printed by a mask printer (Varseo, BEGO, Bremen, Germany) with a temporary material (VarseoSmile Temp A3, BEGO, Bremen, Germany). The second group was milled with a millable temporary material (VitaCAD Temp mono-color, Vita, Bad Säckingen, Germany). The two groups were compression tested until failure to estimate their fracture resistance. The loading forces and travel distance until failure were measured. The statistical analysis was performed using SPSS Version 24.0. We performed multiple t tests and considered a significance level of p <0.05. RESULTS: The mean fracture force of the printed molars was 1189.50 N (±250.85) with a deformation of 1.75 mm (±0.25). The milled molars reached a mean fracture force of 1817.50 N (±258.22) with a deformation of 1.750 mm (±0.20). The printed incisors fractured at 321.63 N (±145.90) with a deformation of 1.94 mm (±0.40), while the milled incisors fractured at 443.38 N (±113.63) with a deformation of 2.26 mm (±0.40). The milled molar group revealed significantly higher mechanical fracture strength than the 3D-printed molar group (P<0.001). However, no significant differences between the 3D-printed incisors and the milled incisors were found (p = 0.084). There was no significant difference in the travel distance until fracture for both the molar group (p = 1.000) and the incisor group (p = 0.129). CONCLUSION: Within the limits of this in vitro investigation, printed and milled temporary crowns withstood masticatory forces and were safe for clinical use.
format Online
Article
Text
id pubmed-10473469
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-104734692023-09-02 The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study Othman, Ahmed Sandmair, Maximillian Alevizakos, Vasilios von See, Constantin PLoS One Research Article BACKGROUND: CAD/CAM has considerably transformed the clinical practice of dentistry. In particular, advanced dental materials produced via digital technologies offer unquestionable benefits, such as ideal mechanical stability, outstanding aesthetics and reliable high precision. Additive manufacturing (AM) technology has promoted new innovations, especially in the field of biomedicine. AIMS: The aim of this study is to analyze the fracture resistance of implant-supported 3D-printed temporary crowns relative to milled crowns by compression testing. METHODS: The study sample included 32 specimens of temporary crowns, which were divided into 16 specimens per group. Each group consisted of eight maxillary central incisor crowns (tooth 11) and eight maxillary molar crowns (tooth 16). The first group (16 specimens) was 3D printed by a mask printer (Varseo, BEGO, Bremen, Germany) with a temporary material (VarseoSmile Temp A3, BEGO, Bremen, Germany). The second group was milled with a millable temporary material (VitaCAD Temp mono-color, Vita, Bad Säckingen, Germany). The two groups were compression tested until failure to estimate their fracture resistance. The loading forces and travel distance until failure were measured. The statistical analysis was performed using SPSS Version 24.0. We performed multiple t tests and considered a significance level of p <0.05. RESULTS: The mean fracture force of the printed molars was 1189.50 N (±250.85) with a deformation of 1.75 mm (±0.25). The milled molars reached a mean fracture force of 1817.50 N (±258.22) with a deformation of 1.750 mm (±0.20). The printed incisors fractured at 321.63 N (±145.90) with a deformation of 1.94 mm (±0.40), while the milled incisors fractured at 443.38 N (±113.63) with a deformation of 2.26 mm (±0.40). The milled molar group revealed significantly higher mechanical fracture strength than the 3D-printed molar group (P<0.001). However, no significant differences between the 3D-printed incisors and the milled incisors were found (p = 0.084). There was no significant difference in the travel distance until fracture for both the molar group (p = 1.000) and the incisor group (p = 0.129). CONCLUSION: Within the limits of this in vitro investigation, printed and milled temporary crowns withstood masticatory forces and were safe for clinical use. Public Library of Science 2023-09-01 /pmc/articles/PMC10473469/ /pubmed/37656728 http://dx.doi.org/10.1371/journal.pone.0285760 Text en © 2023 Othman et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Othman, Ahmed
Sandmair, Maximillian
Alevizakos, Vasilios
von See, Constantin
The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study
title The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study
title_full The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study
title_fullStr The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study
title_full_unstemmed The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study
title_short The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study
title_sort fracture resistance of 3d-printed versus milled provisional crowns: an in vitro study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10473469/
https://www.ncbi.nlm.nih.gov/pubmed/37656728
http://dx.doi.org/10.1371/journal.pone.0285760
work_keys_str_mv AT othmanahmed thefractureresistanceof3dprintedversusmilledprovisionalcrownsaninvitrostudy
AT sandmairmaximillian thefractureresistanceof3dprintedversusmilledprovisionalcrownsaninvitrostudy
AT alevizakosvasilios thefractureresistanceof3dprintedversusmilledprovisionalcrownsaninvitrostudy
AT vonseeconstantin thefractureresistanceof3dprintedversusmilledprovisionalcrownsaninvitrostudy
AT othmanahmed fractureresistanceof3dprintedversusmilledprovisionalcrownsaninvitrostudy
AT sandmairmaximillian fractureresistanceof3dprintedversusmilledprovisionalcrownsaninvitrostudy
AT alevizakosvasilios fractureresistanceof3dprintedversusmilledprovisionalcrownsaninvitrostudy
AT vonseeconstantin fractureresistanceof3dprintedversusmilledprovisionalcrownsaninvitrostudy