Standard versus short stem cemented Exeter(®) when used for primary total hip arthroplasty: a survivorship analysis
AIMS: The aims were to compare the survival of the cemented standard (150 mm) with the short (DDH [35.5 mm offset or less], number 1 short stem [125 mm options of 37.5 mm, 44 mm, 50 mm offset] and revision [44/00/125]) Exeter(®) V40 femoral stems when used for primary total hip arthroplasty (THA). M...