Cargando…

The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement

Background Unicompartmental knee arthroplasty (UKA) is a highly effective surgical procedure used to treat patients with osteoarthritis affecting a single knee compartment. UKA has gained significant popularity, accompanied by an expansion of its surgical indications. This increasing trend can be at...

Descripción completa

Detalles Bibliográficos
Autores principales: Hardy, Vincent, Garaud, Marwan, Hetaimish, Bandar M, Samargandi, Ramy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10475295/
https://www.ncbi.nlm.nih.gov/pubmed/37667718
http://dx.doi.org/10.7759/cureus.42956
_version_ 1785100694820225024
author Hardy, Vincent
Garaud, Marwan
Hetaimish, Bandar M
Samargandi, Ramy
author_facet Hardy, Vincent
Garaud, Marwan
Hetaimish, Bandar M
Samargandi, Ramy
author_sort Hardy, Vincent
collection PubMed
description Background Unicompartmental knee arthroplasty (UKA) is a highly effective surgical procedure used to treat patients with osteoarthritis affecting a single knee compartment. UKA has gained significant popularity, accompanied by an expansion of its surgical indications. This increasing trend can be attributed to the consistently excellent clinical outcomes associated with UKA, which rival those achieved with total knee arthroplasty (TKA). However, despite these advancements, implant rotation malposition remains a prevalent factor contributing to early failure in UKA cases. The aim of this study is to analyze the rotational positioning of femorotibial implants in UKA and to identify an appropriate angle formed by the femoral component and the tibial component using a newly described angle. Methods This was a retrospective study of patients’ data of 40 medial UKA cases of 33 patients who were operated on in our hospital between October 1998 and March 2019. The study introduces a new angle called the "divergence angle." This angle is formed between the lateral portion of the femoral component and the lateral part of the tibial component, as measured on a patellofemoral Merchant view at 30 degrees of knee flexion. The divergence angle was evaluated through radiographic assessment by two independent reviewers. Results According to statistical analysis, the divergence angle was highly reliable with both intra- and inter-observer reproducibility. Intra-observer reproducibility was excellent with an intra-class correlation coefficient (ICC) between 0.901 and 0.933 (p < 0.001). The inter-observer reproducibility was excellent with an ICC of 0.92 (p < 0.001). The Gaussian curve confirmed the normal distribution of the divergence angle values with moderate dispersion of values. The majority of the angles of divergence (85%) measured between the femoral and tibial components were less than 10 degrees (n = 34), with a mean angle of 6.3 ± 4.5°. Conclusion The divergence angle between the femoral and tibial components, measured at 30 degrees of knee flexion using the Merchant view, is an easily accessible, reliable, and reproducible method. This technique enables the assessment of the optimal rotational positioning of implants in medial UKA.
format Online
Article
Text
id pubmed-10475295
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-104752952023-09-04 The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement Hardy, Vincent Garaud, Marwan Hetaimish, Bandar M Samargandi, Ramy Cureus Orthopedics Background Unicompartmental knee arthroplasty (UKA) is a highly effective surgical procedure used to treat patients with osteoarthritis affecting a single knee compartment. UKA has gained significant popularity, accompanied by an expansion of its surgical indications. This increasing trend can be attributed to the consistently excellent clinical outcomes associated with UKA, which rival those achieved with total knee arthroplasty (TKA). However, despite these advancements, implant rotation malposition remains a prevalent factor contributing to early failure in UKA cases. The aim of this study is to analyze the rotational positioning of femorotibial implants in UKA and to identify an appropriate angle formed by the femoral component and the tibial component using a newly described angle. Methods This was a retrospective study of patients’ data of 40 medial UKA cases of 33 patients who were operated on in our hospital between October 1998 and March 2019. The study introduces a new angle called the "divergence angle." This angle is formed between the lateral portion of the femoral component and the lateral part of the tibial component, as measured on a patellofemoral Merchant view at 30 degrees of knee flexion. The divergence angle was evaluated through radiographic assessment by two independent reviewers. Results According to statistical analysis, the divergence angle was highly reliable with both intra- and inter-observer reproducibility. Intra-observer reproducibility was excellent with an intra-class correlation coefficient (ICC) between 0.901 and 0.933 (p < 0.001). The inter-observer reproducibility was excellent with an ICC of 0.92 (p < 0.001). The Gaussian curve confirmed the normal distribution of the divergence angle values with moderate dispersion of values. The majority of the angles of divergence (85%) measured between the femoral and tibial components were less than 10 degrees (n = 34), with a mean angle of 6.3 ± 4.5°. Conclusion The divergence angle between the femoral and tibial components, measured at 30 degrees of knee flexion using the Merchant view, is an easily accessible, reliable, and reproducible method. This technique enables the assessment of the optimal rotational positioning of implants in medial UKA. Cureus 2023-08-04 /pmc/articles/PMC10475295/ /pubmed/37667718 http://dx.doi.org/10.7759/cureus.42956 Text en Copyright © 2023, Hardy et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Hardy, Vincent
Garaud, Marwan
Hetaimish, Bandar M
Samargandi, Ramy
The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement
title The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement
title_full The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement
title_fullStr The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement
title_full_unstemmed The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement
title_short The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement
title_sort reliability of the divergence angle for evaluating rotational implant positioning in medial unicompartmental knee replacement
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10475295/
https://www.ncbi.nlm.nih.gov/pubmed/37667718
http://dx.doi.org/10.7759/cureus.42956
work_keys_str_mv AT hardyvincent thereliabilityofthedivergenceangleforevaluatingrotationalimplantpositioninginmedialunicompartmentalkneereplacement
AT garaudmarwan thereliabilityofthedivergenceangleforevaluatingrotationalimplantpositioninginmedialunicompartmentalkneereplacement
AT hetaimishbandarm thereliabilityofthedivergenceangleforevaluatingrotationalimplantpositioninginmedialunicompartmentalkneereplacement
AT samargandiramy thereliabilityofthedivergenceangleforevaluatingrotationalimplantpositioninginmedialunicompartmentalkneereplacement
AT hardyvincent reliabilityofthedivergenceangleforevaluatingrotationalimplantpositioninginmedialunicompartmentalkneereplacement
AT garaudmarwan reliabilityofthedivergenceangleforevaluatingrotationalimplantpositioninginmedialunicompartmentalkneereplacement
AT hetaimishbandarm reliabilityofthedivergenceangleforevaluatingrotationalimplantpositioninginmedialunicompartmentalkneereplacement
AT samargandiramy reliabilityofthedivergenceangleforevaluatingrotationalimplantpositioninginmedialunicompartmentalkneereplacement