Cargando…

LigaSure technique for splenectomy: A systematic review and meta-analysis

BACKGROUND: This study aimed to clarify the optimal management of the LigaSure technique and conventional techniques during splenectomy. METHODS: All databases, including CBM, CNKI, WFPD, Medline, EMBASE, PubMed, and Cochrane databases up to April 2023, were searched for relevant studies comparing t...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Long, Yu, Qingsheng, Peng, Hui, Zhen, Zhou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10476714/
https://www.ncbi.nlm.nih.gov/pubmed/37657000
http://dx.doi.org/10.1097/MD.0000000000034719
_version_ 1785100992162824192
author Huang, Long
Yu, Qingsheng
Peng, Hui
Zhen, Zhou
author_facet Huang, Long
Yu, Qingsheng
Peng, Hui
Zhen, Zhou
author_sort Huang, Long
collection PubMed
description BACKGROUND: This study aimed to clarify the optimal management of the LigaSure technique and conventional techniques during splenectomy. METHODS: All databases, including CBM, CNKI, WFPD, Medline, EMBASE, PubMed, and Cochrane databases up to April 2023, were searched for relevant studies comparing the LigaSure technique with conventional techniques. Six studies, extracted by 2 independent reviewers, were evaluated for blood loss, operative time, conversion, mortality, hospital stay, and transfusion. RESULTS: The blood loss was significantly higher in the convention group than in the LigaSure group (WMD = −48.98, 95% CI: −62.41 to −35.55, P < .00001). Meanwhile, the mean operative time was significantly shorter in LigaSure group than in convention group (WMD = −10.57; 95% CI: −12.35 to −8.78), P < .00001). No significant differences were found regarding the conversion rate, hospital stay, morbidity, and transfusion. CONCLUSIONS: The LigaSure technique has comparable effects to conventional techniques, but to some extent reduces blood loss and operative time.
format Online
Article
Text
id pubmed-10476714
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-104767142023-09-05 LigaSure technique for splenectomy: A systematic review and meta-analysis Huang, Long Yu, Qingsheng Peng, Hui Zhen, Zhou Medicine (Baltimore) 7100 BACKGROUND: This study aimed to clarify the optimal management of the LigaSure technique and conventional techniques during splenectomy. METHODS: All databases, including CBM, CNKI, WFPD, Medline, EMBASE, PubMed, and Cochrane databases up to April 2023, were searched for relevant studies comparing the LigaSure technique with conventional techniques. Six studies, extracted by 2 independent reviewers, were evaluated for blood loss, operative time, conversion, mortality, hospital stay, and transfusion. RESULTS: The blood loss was significantly higher in the convention group than in the LigaSure group (WMD = −48.98, 95% CI: −62.41 to −35.55, P < .00001). Meanwhile, the mean operative time was significantly shorter in LigaSure group than in convention group (WMD = −10.57; 95% CI: −12.35 to −8.78), P < .00001). No significant differences were found regarding the conversion rate, hospital stay, morbidity, and transfusion. CONCLUSIONS: The LigaSure technique has comparable effects to conventional techniques, but to some extent reduces blood loss and operative time. Lippincott Williams & Wilkins 2023-09-01 /pmc/articles/PMC10476714/ /pubmed/37657000 http://dx.doi.org/10.1097/MD.0000000000034719 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal.
spellingShingle 7100
Huang, Long
Yu, Qingsheng
Peng, Hui
Zhen, Zhou
LigaSure technique for splenectomy: A systematic review and meta-analysis
title LigaSure technique for splenectomy: A systematic review and meta-analysis
title_full LigaSure technique for splenectomy: A systematic review and meta-analysis
title_fullStr LigaSure technique for splenectomy: A systematic review and meta-analysis
title_full_unstemmed LigaSure technique for splenectomy: A systematic review and meta-analysis
title_short LigaSure technique for splenectomy: A systematic review and meta-analysis
title_sort ligasure technique for splenectomy: a systematic review and meta-analysis
topic 7100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10476714/
https://www.ncbi.nlm.nih.gov/pubmed/37657000
http://dx.doi.org/10.1097/MD.0000000000034719
work_keys_str_mv AT huanglong ligasuretechniqueforsplenectomyasystematicreviewandmetaanalysis
AT yuqingsheng ligasuretechniqueforsplenectomyasystematicreviewandmetaanalysis
AT penghui ligasuretechniqueforsplenectomyasystematicreviewandmetaanalysis
AT zhenzhou ligasuretechniqueforsplenectomyasystematicreviewandmetaanalysis