Cargando…
LigaSure technique for splenectomy: A systematic review and meta-analysis
BACKGROUND: This study aimed to clarify the optimal management of the LigaSure technique and conventional techniques during splenectomy. METHODS: All databases, including CBM, CNKI, WFPD, Medline, EMBASE, PubMed, and Cochrane databases up to April 2023, were searched for relevant studies comparing t...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10476714/ https://www.ncbi.nlm.nih.gov/pubmed/37657000 http://dx.doi.org/10.1097/MD.0000000000034719 |
_version_ | 1785100992162824192 |
---|---|
author | Huang, Long Yu, Qingsheng Peng, Hui Zhen, Zhou |
author_facet | Huang, Long Yu, Qingsheng Peng, Hui Zhen, Zhou |
author_sort | Huang, Long |
collection | PubMed |
description | BACKGROUND: This study aimed to clarify the optimal management of the LigaSure technique and conventional techniques during splenectomy. METHODS: All databases, including CBM, CNKI, WFPD, Medline, EMBASE, PubMed, and Cochrane databases up to April 2023, were searched for relevant studies comparing the LigaSure technique with conventional techniques. Six studies, extracted by 2 independent reviewers, were evaluated for blood loss, operative time, conversion, mortality, hospital stay, and transfusion. RESULTS: The blood loss was significantly higher in the convention group than in the LigaSure group (WMD = −48.98, 95% CI: −62.41 to −35.55, P < .00001). Meanwhile, the mean operative time was significantly shorter in LigaSure group than in convention group (WMD = −10.57; 95% CI: −12.35 to −8.78), P < .00001). No significant differences were found regarding the conversion rate, hospital stay, morbidity, and transfusion. CONCLUSIONS: The LigaSure technique has comparable effects to conventional techniques, but to some extent reduces blood loss and operative time. |
format | Online Article Text |
id | pubmed-10476714 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-104767142023-09-05 LigaSure technique for splenectomy: A systematic review and meta-analysis Huang, Long Yu, Qingsheng Peng, Hui Zhen, Zhou Medicine (Baltimore) 7100 BACKGROUND: This study aimed to clarify the optimal management of the LigaSure technique and conventional techniques during splenectomy. METHODS: All databases, including CBM, CNKI, WFPD, Medline, EMBASE, PubMed, and Cochrane databases up to April 2023, were searched for relevant studies comparing the LigaSure technique with conventional techniques. Six studies, extracted by 2 independent reviewers, were evaluated for blood loss, operative time, conversion, mortality, hospital stay, and transfusion. RESULTS: The blood loss was significantly higher in the convention group than in the LigaSure group (WMD = −48.98, 95% CI: −62.41 to −35.55, P < .00001). Meanwhile, the mean operative time was significantly shorter in LigaSure group than in convention group (WMD = −10.57; 95% CI: −12.35 to −8.78), P < .00001). No significant differences were found regarding the conversion rate, hospital stay, morbidity, and transfusion. CONCLUSIONS: The LigaSure technique has comparable effects to conventional techniques, but to some extent reduces blood loss and operative time. Lippincott Williams & Wilkins 2023-09-01 /pmc/articles/PMC10476714/ /pubmed/37657000 http://dx.doi.org/10.1097/MD.0000000000034719 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. |
spellingShingle | 7100 Huang, Long Yu, Qingsheng Peng, Hui Zhen, Zhou LigaSure technique for splenectomy: A systematic review and meta-analysis |
title | LigaSure technique for splenectomy: A systematic review and meta-analysis |
title_full | LigaSure technique for splenectomy: A systematic review and meta-analysis |
title_fullStr | LigaSure technique for splenectomy: A systematic review and meta-analysis |
title_full_unstemmed | LigaSure technique for splenectomy: A systematic review and meta-analysis |
title_short | LigaSure technique for splenectomy: A systematic review and meta-analysis |
title_sort | ligasure technique for splenectomy: a systematic review and meta-analysis |
topic | 7100 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10476714/ https://www.ncbi.nlm.nih.gov/pubmed/37657000 http://dx.doi.org/10.1097/MD.0000000000034719 |
work_keys_str_mv | AT huanglong ligasuretechniqueforsplenectomyasystematicreviewandmetaanalysis AT yuqingsheng ligasuretechniqueforsplenectomyasystematicreviewandmetaanalysis AT penghui ligasuretechniqueforsplenectomyasystematicreviewandmetaanalysis AT zhenzhou ligasuretechniqueforsplenectomyasystematicreviewandmetaanalysis |