Transmission probability filter optimization for Agility MLC in Monaco treatment planning system

In the Monte Carlo‐based treatment planning system (TPS) Monaco, transmission probability filters (TPF) are utilized to describe the transmission through the multi leaf collimator (MLC). By having knowledge of the TPF parameters for various photon beam energies, adjusting the MLC transmission parame...

Descripción completa

Detalles Bibliográficos
Autores principales: Thewes, Lena, Eckl, Miriam, Schneider, Frank
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10476981/
https://www.ncbi.nlm.nih.gov/pubmed/37494135
http://dx.doi.org/10.1002/acm2.14105
_version_ 1785101049641566208
author Thewes, Lena
Eckl, Miriam
Schneider, Frank
author_facet Thewes, Lena
Eckl, Miriam
Schneider, Frank
author_sort Thewes, Lena
collection PubMed
description In the Monte Carlo‐based treatment planning system (TPS) Monaco, transmission probability filters (TPF) are utilized to describe the transmission through the multi leaf collimator (MLC). By having knowledge of the TPF parameters for various photon beam energies, adjusting the MLC transmission parameters becomes easier, enhancing the accuracy of the Monte Carlo algorithm in achieving a dose distribution that closely aligns with the irradiated dose at the Versa HD linear accelerator (linac). The objective of this study was to determine the TPF parameters for 6MV, 10MV, 6MV flattening filter free (FFF) and 10MV FFF for a Versa HD linac equipped with Agility MLC. The TPF parameters were adjusted using point dose measurements and vendor‐provided fields specifically designed to fine‐tune the MLC. After adjusting the TPF parameters, a gamma passing rate (GPR) analysis was conducted on 25 treatment plans to ensure that the Monte Carlo model, with the updated TPF parameters, accurately matched the actual linac delivery. The TPF values ranged from 0.0018 to 0.0032 for leaf transmission and 1.15 to 1.25 for Leaf Tip leakage across the different energies. The average GPR ranged from 97.8% for 10MV FFF to 98.5% for 6MV photon energies. Additionally, the TPF parameters for 6MV obtained in this study were consistent with previously published TPF values for 6MV photon energy. Hence, it was concluded that optimizing the TPF does not need to be performed for every individual Versa HD linac with Agility MLC. Instead, the published parameters can be applied to other Versa HD linacs to enhance clinical accuracy. In conclusion, this study determined the TPF parameters for 6MV and previously unpublished photon energies 10MV, 6MV FFF and 10MV FFF. These parameters can be easily transferred to other facilities, resulting in improved agreement between the dose distribution from the TPS and the linac.
format Online
Article
Text
id pubmed-10476981
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-104769812023-09-05 Transmission probability filter optimization for Agility MLC in Monaco treatment planning system Thewes, Lena Eckl, Miriam Schneider, Frank J Appl Clin Med Phys Technical Notes In the Monte Carlo‐based treatment planning system (TPS) Monaco, transmission probability filters (TPF) are utilized to describe the transmission through the multi leaf collimator (MLC). By having knowledge of the TPF parameters for various photon beam energies, adjusting the MLC transmission parameters becomes easier, enhancing the accuracy of the Monte Carlo algorithm in achieving a dose distribution that closely aligns with the irradiated dose at the Versa HD linear accelerator (linac). The objective of this study was to determine the TPF parameters for 6MV, 10MV, 6MV flattening filter free (FFF) and 10MV FFF for a Versa HD linac equipped with Agility MLC. The TPF parameters were adjusted using point dose measurements and vendor‐provided fields specifically designed to fine‐tune the MLC. After adjusting the TPF parameters, a gamma passing rate (GPR) analysis was conducted on 25 treatment plans to ensure that the Monte Carlo model, with the updated TPF parameters, accurately matched the actual linac delivery. The TPF values ranged from 0.0018 to 0.0032 for leaf transmission and 1.15 to 1.25 for Leaf Tip leakage across the different energies. The average GPR ranged from 97.8% for 10MV FFF to 98.5% for 6MV photon energies. Additionally, the TPF parameters for 6MV obtained in this study were consistent with previously published TPF values for 6MV photon energy. Hence, it was concluded that optimizing the TPF does not need to be performed for every individual Versa HD linac with Agility MLC. Instead, the published parameters can be applied to other Versa HD linacs to enhance clinical accuracy. In conclusion, this study determined the TPF parameters for 6MV and previously unpublished photon energies 10MV, 6MV FFF and 10MV FFF. These parameters can be easily transferred to other facilities, resulting in improved agreement between the dose distribution from the TPS and the linac. John Wiley and Sons Inc. 2023-07-26 /pmc/articles/PMC10476981/ /pubmed/37494135 http://dx.doi.org/10.1002/acm2.14105 Text en © 2023 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Thewes, Lena
Eckl, Miriam
Schneider, Frank
Transmission probability filter optimization for Agility MLC in Monaco treatment planning system
title Transmission probability filter optimization for Agility MLC in Monaco treatment planning system
title_full Transmission probability filter optimization for Agility MLC in Monaco treatment planning system
title_fullStr Transmission probability filter optimization for Agility MLC in Monaco treatment planning system
title_full_unstemmed Transmission probability filter optimization for Agility MLC in Monaco treatment planning system
title_short Transmission probability filter optimization for Agility MLC in Monaco treatment planning system
title_sort transmission probability filter optimization for agility mlc in monaco treatment planning system
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10476981/
https://www.ncbi.nlm.nih.gov/pubmed/37494135
http://dx.doi.org/10.1002/acm2.14105
work_keys_str_mv AT theweslena transmissionprobabilityfilteroptimizationforagilitymlcinmonacotreatmentplanningsystem
AT ecklmiriam transmissionprobabilityfilteroptimizationforagilitymlcinmonacotreatmentplanningsystem
AT schneiderfrank transmissionprobabilityfilteroptimizationforagilitymlcinmonacotreatmentplanningsystem