Cargando…

Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis

BACKGROUND: Newly developed catheter ablation (CA) techniques, such as laser balloon ablation (LBA) and cryoballoon ablation (CBA), have been introduced in recent years and emerged as valuable alternatives to conventional radiofrequency CA strategies for paroxysmal atrial fibrillation (PAF) patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Ye, Wenyi, Chen, Qian, Fan, Guangci, Zhou, Xinbin, Wang, Xiao, Mao, Wei, Li, JuanJuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10478246/
https://www.ncbi.nlm.nih.gov/pubmed/37674807
http://dx.doi.org/10.3389/fcvm.2023.1229223
_version_ 1785101305625182208
author Ye, Wenyi
Chen, Qian
Fan, Guangci
Zhou, Xinbin
Wang, Xiao
Mao, Wei
Li, JuanJuan
author_facet Ye, Wenyi
Chen, Qian
Fan, Guangci
Zhou, Xinbin
Wang, Xiao
Mao, Wei
Li, JuanJuan
author_sort Ye, Wenyi
collection PubMed
description BACKGROUND: Newly developed catheter ablation (CA) techniques, such as laser balloon ablation (LBA) and cryoballoon ablation (CBA), have been introduced in recent years and emerged as valuable alternatives to conventional radiofrequency CA strategies for paroxysmal atrial fibrillation (PAF) patients. However, evidence comparing LBA and CBA remain controversial. Thus, we conducted this meta-analysis to assess the efficacy and safety between these two techniques. METHODS: Scientific databases (PubMed, Embase) and relevant websites (the Cochrane Library, ClinicalTrials.gov) were systematically searched from inception to March 2023. The primary outcomes of interest were the AF recurrence and the procedure-related complications. Secondary outcomes included procedural time, fluoroscopy time, and left atrial (LA) dwell time. RESULTS: Seven clinical trials with a total of 637 patients were finally enrolled. No significant differences were found between LBA and CBA in terms of AF recurrence [16.3% vs. 22.7%, odds ratio (OR) = 0.66, 95% confidence interval (CI): 0.42–1.05, p = 0.078] or total procedural-related complications (8.4% vs. 6.4%, OR = 1.33, 95% CI: 0.71–2.51, p = 0.371). LBA had a significantly longer procedural time [weighted mean difference (WMD) = 38.03 min, 95% CI: 13.48–62.58 min, p = 0.002] and LA dwell time (WMD = 46.67 min, 95% CI: 14.63–78.72 min, p = 0.004) than CBA, but tended to have shorter fluoroscopy time. CONCLUSIONS: LBA and CBA treatment have comparable efficacy and safety for PAF patients. LBA was associated with longer procedural and LA dwell times compared with CBA. Further large-scale studies are warranted to compare these two techniques with the newest generations. Systematic Review Registration: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=426513, identifier (CRD42023426513).
format Online
Article
Text
id pubmed-10478246
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-104782462023-09-06 Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis Ye, Wenyi Chen, Qian Fan, Guangci Zhou, Xinbin Wang, Xiao Mao, Wei Li, JuanJuan Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: Newly developed catheter ablation (CA) techniques, such as laser balloon ablation (LBA) and cryoballoon ablation (CBA), have been introduced in recent years and emerged as valuable alternatives to conventional radiofrequency CA strategies for paroxysmal atrial fibrillation (PAF) patients. However, evidence comparing LBA and CBA remain controversial. Thus, we conducted this meta-analysis to assess the efficacy and safety between these two techniques. METHODS: Scientific databases (PubMed, Embase) and relevant websites (the Cochrane Library, ClinicalTrials.gov) were systematically searched from inception to March 2023. The primary outcomes of interest were the AF recurrence and the procedure-related complications. Secondary outcomes included procedural time, fluoroscopy time, and left atrial (LA) dwell time. RESULTS: Seven clinical trials with a total of 637 patients were finally enrolled. No significant differences were found between LBA and CBA in terms of AF recurrence [16.3% vs. 22.7%, odds ratio (OR) = 0.66, 95% confidence interval (CI): 0.42–1.05, p = 0.078] or total procedural-related complications (8.4% vs. 6.4%, OR = 1.33, 95% CI: 0.71–2.51, p = 0.371). LBA had a significantly longer procedural time [weighted mean difference (WMD) = 38.03 min, 95% CI: 13.48–62.58 min, p = 0.002] and LA dwell time (WMD = 46.67 min, 95% CI: 14.63–78.72 min, p = 0.004) than CBA, but tended to have shorter fluoroscopy time. CONCLUSIONS: LBA and CBA treatment have comparable efficacy and safety for PAF patients. LBA was associated with longer procedural and LA dwell times compared with CBA. Further large-scale studies are warranted to compare these two techniques with the newest generations. Systematic Review Registration: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=426513, identifier (CRD42023426513). Frontiers Media S.A. 2023-08-22 /pmc/articles/PMC10478246/ /pubmed/37674807 http://dx.doi.org/10.3389/fcvm.2023.1229223 Text en © 2023 Ye, Chen, Fan, Zhou, Wang, Mao and Li. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Ye, Wenyi
Chen, Qian
Fan, Guangci
Zhou, Xinbin
Wang, Xiao
Mao, Wei
Li, JuanJuan
Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis
title Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis
title_full Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis
title_fullStr Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis
title_full_unstemmed Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis
title_short Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis
title_sort efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10478246/
https://www.ncbi.nlm.nih.gov/pubmed/37674807
http://dx.doi.org/10.3389/fcvm.2023.1229223
work_keys_str_mv AT yewenyi efficacyandsafetyofvisuallyguidedlaserballoonversuscryoballoonablationforparoxysmalatrialfibrillationasystematicreviewandmetaanalysis
AT chenqian efficacyandsafetyofvisuallyguidedlaserballoonversuscryoballoonablationforparoxysmalatrialfibrillationasystematicreviewandmetaanalysis
AT fanguangci efficacyandsafetyofvisuallyguidedlaserballoonversuscryoballoonablationforparoxysmalatrialfibrillationasystematicreviewandmetaanalysis
AT zhouxinbin efficacyandsafetyofvisuallyguidedlaserballoonversuscryoballoonablationforparoxysmalatrialfibrillationasystematicreviewandmetaanalysis
AT wangxiao efficacyandsafetyofvisuallyguidedlaserballoonversuscryoballoonablationforparoxysmalatrialfibrillationasystematicreviewandmetaanalysis
AT maowei efficacyandsafetyofvisuallyguidedlaserballoonversuscryoballoonablationforparoxysmalatrialfibrillationasystematicreviewandmetaanalysis
AT lijuanjuan efficacyandsafetyofvisuallyguidedlaserballoonversuscryoballoonablationforparoxysmalatrialfibrillationasystematicreviewandmetaanalysis