Cargando…

Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of MDP-containing zirconia primer after aging

OBJECTIVES: Successful ceramic restorations depend on the strong bonding with resin cement and even stress distribution. The aim of this study was to evaluate the impact of adding MDP-containing zirconia primer before self-adhesive resin cements with different functional acidic monomers on fracture...

Descripción completa

Detalles Bibliográficos
Autores principales: Tyor, Shaima, Al-Zordk, Walid, Sakrana, Amal Abdelsamad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10478297/
https://www.ncbi.nlm.nih.gov/pubmed/37670286
http://dx.doi.org/10.1186/s12903-023-03365-5
_version_ 1785101318129451008
author Tyor, Shaima
Al-Zordk, Walid
Sakrana, Amal Abdelsamad
author_facet Tyor, Shaima
Al-Zordk, Walid
Sakrana, Amal Abdelsamad
author_sort Tyor, Shaima
collection PubMed
description OBJECTIVES: Successful ceramic restorations depend on the strong bonding with resin cement and even stress distribution. The aim of this study was to evaluate the impact of adding MDP-containing zirconia primer before self-adhesive resin cements with different functional acidic monomers on fracture resistance of monolithic zirconia crown. MATERIALS AND METHODS: Eighty defect-free human maxillary premolars were divided according to the cement type and application of MDP-containing zirconia primer into eight groups (n = 10): Calibra Universal (C), Calibra Universal combined with zirconia primer (CZ), RelyX U200 (R), RelyXU200 combined with zirconia primer (RZ), Panavia SA Cement Plus (P), Panavia SA Cement Plus combined with zirconia primer (PZ), Multilink Speed (M), and Multilink Speed combined with zirconia primer (MZ). After teeth preparation and fabrication of zirconia crowns, each crown was bonded to its corresponding tooth. All specimens were subjected to 10,000 thermocycles between 5 and 55°C, followed by cyclic load (50 N) for 240,000 cycles. Each specimen was subjected to a static axial load until fracture using universal testing machine and the fracture load was recorded. The fracture mode studied and recorded. The fracture load results were analyzed using two-way ANOVA test (α = 0.05). RESULTS: A significant interaction (P = 0.038) of combining MDP-containing zirconia primer and cement type on fracture resistance of monolithic zirconia crown was detected. The mean fracture load values of zirconia crown were significantly influenced by the combined application of the MDP-containing zirconia primer with Calibra Universal (P = 0.01), RelyX U200 (P < 0.001), and Multilink Speed (P = 0.038), while there was no significant difference with Panavia SA Cement Plus (P = 0.660). There was significant difference (F = 20.69, P < 0.001) between the mean fracture loads of groups with self-adhesive cements (C, R, P, and M groups). The highest fracture load was recorded with RZ group (2446.90 ± 126.72 N) while the lowest fracture load was recorded with C group (1623.18 ± 149.86 N). CONCLUSIONS: The self-adhesive resin cement with different acidic functional monomer affects the fracture resistance of monolithic zirconia crown. Application of MDP-containing primer could improve the fracture resistance of monolithic zirconia crown with most self-adhesive cements. The application of an MDP-containing primer had no impact on the fracture resistance of monolithic translucent zirconia crown bonded by MDP-containing self-adhesive resin cement.
format Online
Article
Text
id pubmed-10478297
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-104782972023-09-06 Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of MDP-containing zirconia primer after aging Tyor, Shaima Al-Zordk, Walid Sakrana, Amal Abdelsamad BMC Oral Health Research OBJECTIVES: Successful ceramic restorations depend on the strong bonding with resin cement and even stress distribution. The aim of this study was to evaluate the impact of adding MDP-containing zirconia primer before self-adhesive resin cements with different functional acidic monomers on fracture resistance of monolithic zirconia crown. MATERIALS AND METHODS: Eighty defect-free human maxillary premolars were divided according to the cement type and application of MDP-containing zirconia primer into eight groups (n = 10): Calibra Universal (C), Calibra Universal combined with zirconia primer (CZ), RelyX U200 (R), RelyXU200 combined with zirconia primer (RZ), Panavia SA Cement Plus (P), Panavia SA Cement Plus combined with zirconia primer (PZ), Multilink Speed (M), and Multilink Speed combined with zirconia primer (MZ). After teeth preparation and fabrication of zirconia crowns, each crown was bonded to its corresponding tooth. All specimens were subjected to 10,000 thermocycles between 5 and 55°C, followed by cyclic load (50 N) for 240,000 cycles. Each specimen was subjected to a static axial load until fracture using universal testing machine and the fracture load was recorded. The fracture mode studied and recorded. The fracture load results were analyzed using two-way ANOVA test (α = 0.05). RESULTS: A significant interaction (P = 0.038) of combining MDP-containing zirconia primer and cement type on fracture resistance of monolithic zirconia crown was detected. The mean fracture load values of zirconia crown were significantly influenced by the combined application of the MDP-containing zirconia primer with Calibra Universal (P = 0.01), RelyX U200 (P < 0.001), and Multilink Speed (P = 0.038), while there was no significant difference with Panavia SA Cement Plus (P = 0.660). There was significant difference (F = 20.69, P < 0.001) between the mean fracture loads of groups with self-adhesive cements (C, R, P, and M groups). The highest fracture load was recorded with RZ group (2446.90 ± 126.72 N) while the lowest fracture load was recorded with C group (1623.18 ± 149.86 N). CONCLUSIONS: The self-adhesive resin cement with different acidic functional monomer affects the fracture resistance of monolithic zirconia crown. Application of MDP-containing primer could improve the fracture resistance of monolithic zirconia crown with most self-adhesive cements. The application of an MDP-containing primer had no impact on the fracture resistance of monolithic translucent zirconia crown bonded by MDP-containing self-adhesive resin cement. BioMed Central 2023-09-05 /pmc/articles/PMC10478297/ /pubmed/37670286 http://dx.doi.org/10.1186/s12903-023-03365-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Tyor, Shaima
Al-Zordk, Walid
Sakrana, Amal Abdelsamad
Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of MDP-containing zirconia primer after aging
title Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of MDP-containing zirconia primer after aging
title_full Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of MDP-containing zirconia primer after aging
title_fullStr Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of MDP-containing zirconia primer after aging
title_full_unstemmed Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of MDP-containing zirconia primer after aging
title_short Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of MDP-containing zirconia primer after aging
title_sort fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: influence of mdp-containing zirconia primer after aging
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10478297/
https://www.ncbi.nlm.nih.gov/pubmed/37670286
http://dx.doi.org/10.1186/s12903-023-03365-5
work_keys_str_mv AT tyorshaima fractureresistanceofmonolithictranslucentzirconiacrownbondedwithdifferentselfadhesiveresincementinfluenceofmdpcontainingzirconiaprimerafteraging
AT alzordkwalid fractureresistanceofmonolithictranslucentzirconiacrownbondedwithdifferentselfadhesiveresincementinfluenceofmdpcontainingzirconiaprimerafteraging
AT sakranaamalabdelsamad fractureresistanceofmonolithictranslucentzirconiacrownbondedwithdifferentselfadhesiveresincementinfluenceofmdpcontainingzirconiaprimerafteraging