Cargando…
Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma
BACKGROUND: Vascular mechanisms are implicated in many ocular diseases. Therefore, different vascular imaging modalities are used in management of such conditions. Optical coherence tomography angiography (OCTA) has high spatial resolution and segmentable 3D volumetric sampling enabling isolation of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10478436/ https://www.ncbi.nlm.nih.gov/pubmed/37667242 http://dx.doi.org/10.1186/s12886-023-03108-8 |
_version_ | 1785101350010355712 |
---|---|
author | Ameen Ismail, Ahmed Sadek, Sherin Kamal, Mahmoud Hatata, Ragai |
author_facet | Ameen Ismail, Ahmed Sadek, Sherin Kamal, Mahmoud Hatata, Ragai |
author_sort | Ameen Ismail, Ahmed |
collection | PubMed |
description | BACKGROUND: Vascular mechanisms are implicated in many ocular diseases. Therefore, different vascular imaging modalities are used in management of such conditions. Optical coherence tomography angiography (OCTA) has high spatial resolution and segmentable 3D volumetric sampling enabling isolation of retinal and peripapillary vascular beds. However, OCTA only indirectly derives quantitative flow data i.e. velocimetry through methods and algorithms liable to limitations like signal saturation. This study introduces and validates novel mathematical OCTA flow indices that may compensate for some OCTA velocimetric limitations. METHODS: Thirty-seven eyes of 23 POAG patients were included. Each underwent baseline and follow-up assessment one month thereafter. Assessment comprised full ophthalmological examination, intraocular pressure (IOP), systemic arterial blood pressure (SABP) and OCTA macula and ONH. Angiograms were processed using ImageJ to calculate OCTA intensity-based flow indices (FIOs), for superficial vascular plexus (SVP), deep vascular plexus (DVP) and optic nerve head vascular plexus (ONH-RPC), i.e. SFIO, DFIO and ONHFIO respectively. Mean ocular perfusion pressure (MOPP) was calculated using IOP and SABP. OCTA vascular densities (VD) and MOPP were used to calculate three respective mathematical flow indices (FIMs) for SVP, DVP and ONH-RPC, based on Hagen-Poiseuille law, i.e. SFIM, DFIM, ONHFIM respectively. Pearson test was used for correlation between the two sets of indices. Intraclass correlation coefficient (ICC) was tested for baseline and follow-up values for each index. RESULTS: There was positive correlation between the three FIMs and their respective FIOs at baseline and follow-up ranging between high and moderate. Correlation coefficients (CCs) were 0.773 and 0.609 for SFIM and SFIO P-value < 0.001, 0.829 and 0.624 for DFIM and DFIO P-value < 0.001 and 0.516 and 0.737 for ONHFIM P-value = 0.001 for baseline and follow-up respectively. ICCs were 0.772 P-value < 0.001, 0.328 P-value = 0.022 and 0.888 P-value < 0.001 for SFIM, DFIM and ONHFIM respectively. For SFIO, DFIO and ONHFIO, ICCs were 0.420 P-value = 0.004, 0.079 P-value = 0.320 and 0.833 P-value < 0.001 respectively. CONCLUSION: The novel FIMs are reliable alternatives to FIOs and may compensate for OCTA signal saturation in extremes of MOPP. SFIM and ONHFIM showed high ICCs with excellent reliability. While DFIM demonstrated low ICC indicating poor reliability, it still performed better than its corresponding DFIO. |
format | Online Article Text |
id | pubmed-10478436 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-104784362023-09-06 Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma Ameen Ismail, Ahmed Sadek, Sherin Kamal, Mahmoud Hatata, Ragai BMC Ophthalmol Research BACKGROUND: Vascular mechanisms are implicated in many ocular diseases. Therefore, different vascular imaging modalities are used in management of such conditions. Optical coherence tomography angiography (OCTA) has high spatial resolution and segmentable 3D volumetric sampling enabling isolation of retinal and peripapillary vascular beds. However, OCTA only indirectly derives quantitative flow data i.e. velocimetry through methods and algorithms liable to limitations like signal saturation. This study introduces and validates novel mathematical OCTA flow indices that may compensate for some OCTA velocimetric limitations. METHODS: Thirty-seven eyes of 23 POAG patients were included. Each underwent baseline and follow-up assessment one month thereafter. Assessment comprised full ophthalmological examination, intraocular pressure (IOP), systemic arterial blood pressure (SABP) and OCTA macula and ONH. Angiograms were processed using ImageJ to calculate OCTA intensity-based flow indices (FIOs), for superficial vascular plexus (SVP), deep vascular plexus (DVP) and optic nerve head vascular plexus (ONH-RPC), i.e. SFIO, DFIO and ONHFIO respectively. Mean ocular perfusion pressure (MOPP) was calculated using IOP and SABP. OCTA vascular densities (VD) and MOPP were used to calculate three respective mathematical flow indices (FIMs) for SVP, DVP and ONH-RPC, based on Hagen-Poiseuille law, i.e. SFIM, DFIM, ONHFIM respectively. Pearson test was used for correlation between the two sets of indices. Intraclass correlation coefficient (ICC) was tested for baseline and follow-up values for each index. RESULTS: There was positive correlation between the three FIMs and their respective FIOs at baseline and follow-up ranging between high and moderate. Correlation coefficients (CCs) were 0.773 and 0.609 for SFIM and SFIO P-value < 0.001, 0.829 and 0.624 for DFIM and DFIO P-value < 0.001 and 0.516 and 0.737 for ONHFIM P-value = 0.001 for baseline and follow-up respectively. ICCs were 0.772 P-value < 0.001, 0.328 P-value = 0.022 and 0.888 P-value < 0.001 for SFIM, DFIM and ONHFIM respectively. For SFIO, DFIO and ONHFIO, ICCs were 0.420 P-value = 0.004, 0.079 P-value = 0.320 and 0.833 P-value < 0.001 respectively. CONCLUSION: The novel FIMs are reliable alternatives to FIOs and may compensate for OCTA signal saturation in extremes of MOPP. SFIM and ONHFIM showed high ICCs with excellent reliability. While DFIM demonstrated low ICC indicating poor reliability, it still performed better than its corresponding DFIO. BioMed Central 2023-09-05 /pmc/articles/PMC10478436/ /pubmed/37667242 http://dx.doi.org/10.1186/s12886-023-03108-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ameen Ismail, Ahmed Sadek, Sherin Kamal, Mahmoud Hatata, Ragai Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma |
title | Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma |
title_full | Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma |
title_fullStr | Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma |
title_full_unstemmed | Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma |
title_short | Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma |
title_sort | validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10478436/ https://www.ncbi.nlm.nih.gov/pubmed/37667242 http://dx.doi.org/10.1186/s12886-023-03108-8 |
work_keys_str_mv | AT ameenismailahmed validityofanovelopticalcoherencetomographyangiographyflowindexinacohortofprimaryopenangleglaucoma AT sadeksherin validityofanovelopticalcoherencetomographyangiographyflowindexinacohortofprimaryopenangleglaucoma AT kamalmahmoud validityofanovelopticalcoherencetomographyangiographyflowindexinacohortofprimaryopenangleglaucoma AT hatataragai validityofanovelopticalcoherencetomographyangiographyflowindexinacohortofprimaryopenangleglaucoma |