Cargando…

Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation

Intra-aortic balloon pump (IABP) use during CPR has been scarcely studied. Intra-caval balloon pump (ICBP) may decrease backward venous flow during CPR. Mechanical chest compressions (MCC) were initiated after 10 min of cardiac arrest in anesthetized pigs. After 5 min of MCC, IABP (n = 6) or ICBP (n...

Descripción completa

Detalles Bibliográficos
Autores principales: Dogan, Emanuel M., Axelsson, Birger, Jauring, Oskar, Hörer, Tal M., Nilsson, Kristofer F., Edström, Måns
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10480270/
https://www.ncbi.nlm.nih.gov/pubmed/36481982
http://dx.doi.org/10.1007/s12265-022-10343-9
_version_ 1785101757556195328
author Dogan, Emanuel M.
Axelsson, Birger
Jauring, Oskar
Hörer, Tal M.
Nilsson, Kristofer F.
Edström, Måns
author_facet Dogan, Emanuel M.
Axelsson, Birger
Jauring, Oskar
Hörer, Tal M.
Nilsson, Kristofer F.
Edström, Måns
author_sort Dogan, Emanuel M.
collection PubMed
description Intra-aortic balloon pump (IABP) use during CPR has been scarcely studied. Intra-caval balloon pump (ICBP) may decrease backward venous flow during CPR. Mechanical chest compressions (MCC) were initiated after 10 min of cardiac arrest in anesthetized pigs. After 5 min of MCC, IABP (n = 6) or ICBP (n = 6) was initiated. The MCC device and the IABP/ICBP had slightly different frequencies, inducing a progressive peak pressure phase shift. IABP inflation 0.15 s before MCC significantly increased mean arterial pressure (MAP) and carotid blood flow (CBF) compared to inflation 0.10 s after MCC and to MCC only. Coronary perfusion pressure significantly increased with IABP inflation 0.25 s before MCC compared to inflation at MCC. ICBP inflation before MCC significantly increased MAP and CBF compared to inflation after MCC but not compared to MCC only. This shows the potential of IABP in CPR when optimally synchronized with MCC. GRAPHICAL ABSTRACT: The effect of timing of intra-aortic balloon pump (IABP) inflation during mechanical chest compressions (MCC) on hemodynamics. Data from12 anesthetized pigs. [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12265-022-10343-9.
format Online
Article
Text
id pubmed-10480270
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-104802702023-09-07 Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation Dogan, Emanuel M. Axelsson, Birger Jauring, Oskar Hörer, Tal M. Nilsson, Kristofer F. Edström, Måns J Cardiovasc Transl Res Original Article Intra-aortic balloon pump (IABP) use during CPR has been scarcely studied. Intra-caval balloon pump (ICBP) may decrease backward venous flow during CPR. Mechanical chest compressions (MCC) were initiated after 10 min of cardiac arrest in anesthetized pigs. After 5 min of MCC, IABP (n = 6) or ICBP (n = 6) was initiated. The MCC device and the IABP/ICBP had slightly different frequencies, inducing a progressive peak pressure phase shift. IABP inflation 0.15 s before MCC significantly increased mean arterial pressure (MAP) and carotid blood flow (CBF) compared to inflation 0.10 s after MCC and to MCC only. Coronary perfusion pressure significantly increased with IABP inflation 0.25 s before MCC compared to inflation at MCC. ICBP inflation before MCC significantly increased MAP and CBF compared to inflation after MCC but not compared to MCC only. This shows the potential of IABP in CPR when optimally synchronized with MCC. GRAPHICAL ABSTRACT: The effect of timing of intra-aortic balloon pump (IABP) inflation during mechanical chest compressions (MCC) on hemodynamics. Data from12 anesthetized pigs. [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12265-022-10343-9. Springer US 2022-12-08 2023 /pmc/articles/PMC10480270/ /pubmed/36481982 http://dx.doi.org/10.1007/s12265-022-10343-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Dogan, Emanuel M.
Axelsson, Birger
Jauring, Oskar
Hörer, Tal M.
Nilsson, Kristofer F.
Edström, Måns
Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation
title Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation
title_full Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation
title_fullStr Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation
title_full_unstemmed Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation
title_short Intra-aortic and Intra-caval Balloon Pump Devices in Experimental Non-traumatic Cardiac Arrest and Cardiopulmonary Resuscitation
title_sort intra-aortic and intra-caval balloon pump devices in experimental non-traumatic cardiac arrest and cardiopulmonary resuscitation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10480270/
https://www.ncbi.nlm.nih.gov/pubmed/36481982
http://dx.doi.org/10.1007/s12265-022-10343-9
work_keys_str_mv AT doganemanuelm intraaorticandintracavalballoonpumpdevicesinexperimentalnontraumaticcardiacarrestandcardiopulmonaryresuscitation
AT axelssonbirger intraaorticandintracavalballoonpumpdevicesinexperimentalnontraumaticcardiacarrestandcardiopulmonaryresuscitation
AT jauringoskar intraaorticandintracavalballoonpumpdevicesinexperimentalnontraumaticcardiacarrestandcardiopulmonaryresuscitation
AT horertalm intraaorticandintracavalballoonpumpdevicesinexperimentalnontraumaticcardiacarrestandcardiopulmonaryresuscitation
AT nilssonkristoferf intraaorticandintracavalballoonpumpdevicesinexperimentalnontraumaticcardiacarrestandcardiopulmonaryresuscitation
AT edstrommans intraaorticandintracavalballoonpumpdevicesinexperimentalnontraumaticcardiacarrestandcardiopulmonaryresuscitation