A Novel Methodology to Estimate Bone Mechanical Properties Using Dual-Energy Imaging to Improve Pedicle Screw Fixation

OBJECTIVE: To develop a methodology to improve the representation of the mechanical properties of a vertebral finite element model (FEM) based on a new dual-energy (DE) imaging technology to improve pedicle screw fixation. METHODS: Bone-calibrated radiographs were generated with dual-energy imaging...

Descripción completa

Detalles Bibliográficos
Autores principales: Barrera, Carolina Solorzano, Villemure, Isabelle, Aubin, Carl-Éric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Society of Musculoskeletal and Neuronal Interactions 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10483819/
https://www.ncbi.nlm.nih.gov/pubmed/37654217
Descripción
Sumario:OBJECTIVE: To develop a methodology to improve the representation of the mechanical properties of a vertebral finite element model (FEM) based on a new dual-energy (DE) imaging technology to improve pedicle screw fixation. METHODS: Bone-calibrated radiographs were generated with dual-energy imaging technology in order to estimate the mechanical properties of the trabecular bone. Properties were included in regions of interest in four vertebral FEMs representing heterogeneity and homogeneity, as a realistic and reference model, respectively. Biomechanical parameters were measured during screw pull-out testing to evaluate pedicle screw fixation. RESULTS: Simulations with property distributions deduced from dual-energy imaging characterization (heterogeneous models) induced an increase in biomechanical indicators versus with a homogeneous representation, implying different behaviors for the subject-specific models. CONCLUSION: The presented methodology allows a patient-specific representation of bone quality in a FEM using new DE imaging technology. Consideration of individualized bone distribution in a spinal FEM improves the perspective of orthopedic surgical planning over otherwise underestimated results using a homogeneous representation.