Cargando…
Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems—An In vitro Study
AIM: To assess the canal transportation and centering ability in the mandibular first molars’ curved mesiobuccal canals after instrumentation with file systems XP endo Shaper, self-adjusting File (SAF), Hyflex EDM, Pro Taper NEXT, WaveOne Gold, and K files with the help of Cone-Beam Computed Tomogra...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10485439/ https://www.ncbi.nlm.nih.gov/pubmed/37694024 http://dx.doi.org/10.4103/jpbs.jpbs_157_23 |
_version_ | 1785102786123268096 |
---|---|
author | Langaliya, Akshayraj Kothari, Anjali Buch, Aastha Dave, Riya Shah, Jinali Shah, Nishtha |
author_facet | Langaliya, Akshayraj Kothari, Anjali Buch, Aastha Dave, Riya Shah, Jinali Shah, Nishtha |
author_sort | Langaliya, Akshayraj |
collection | PubMed |
description | AIM: To assess the canal transportation and centering ability in the mandibular first molars’ curved mesiobuccal canals after instrumentation with file systems XP endo Shaper, self-adjusting File (SAF), Hyflex EDM, Pro Taper NEXT, WaveOne Gold, and K files with the help of Cone-Beam Computed Tomography (CBCT). MATERIALS AND METHODS: Ninety recently extracted mandibular first molars with mesiobuccal roots that had a 25-30 degree canal curvature were assessed. Following preoperative CBCT scans, teeth were allocated randomly to six experimental groups of fifteen. After preparation with XP endo Shaper, SAF, Hyflex EDM, Pro Taper Next, WaveOne Gold, and K files, post-instrumentation scans were taken using same parameters as pre operative scans. At 3 mm, 6 mm, and 9 mm from the apex, samples were assessed for canal transportation and centering ratio. RESULTS: Apical transportation was least for XP endo Shaper as compared to other groups except SAF and the results were statistically significant. K file showed the highest apical transportation toward the lateral wall of the root canal. XP endo Shaper was better in maintaining centering ability of middle and apical third of canal and SAF was better in maintaining centering ability of coronal third. CONCLUSION: In root canal preparation, least apical transportation and better centering ability with XP endo Shaper than other file systems compared. K file showed the highest transportation. |
format | Online Article Text |
id | pubmed-10485439 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-104854392023-09-09 Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems—An In vitro Study Langaliya, Akshayraj Kothari, Anjali Buch, Aastha Dave, Riya Shah, Jinali Shah, Nishtha J Pharm Bioallied Sci Original Article AIM: To assess the canal transportation and centering ability in the mandibular first molars’ curved mesiobuccal canals after instrumentation with file systems XP endo Shaper, self-adjusting File (SAF), Hyflex EDM, Pro Taper NEXT, WaveOne Gold, and K files with the help of Cone-Beam Computed Tomography (CBCT). MATERIALS AND METHODS: Ninety recently extracted mandibular first molars with mesiobuccal roots that had a 25-30 degree canal curvature were assessed. Following preoperative CBCT scans, teeth were allocated randomly to six experimental groups of fifteen. After preparation with XP endo Shaper, SAF, Hyflex EDM, Pro Taper Next, WaveOne Gold, and K files, post-instrumentation scans were taken using same parameters as pre operative scans. At 3 mm, 6 mm, and 9 mm from the apex, samples were assessed for canal transportation and centering ratio. RESULTS: Apical transportation was least for XP endo Shaper as compared to other groups except SAF and the results were statistically significant. K file showed the highest apical transportation toward the lateral wall of the root canal. XP endo Shaper was better in maintaining centering ability of middle and apical third of canal and SAF was better in maintaining centering ability of coronal third. CONCLUSION: In root canal preparation, least apical transportation and better centering ability with XP endo Shaper than other file systems compared. K file showed the highest transportation. Wolters Kluwer - Medknow 2023-07 2023-07-11 /pmc/articles/PMC10485439/ /pubmed/37694024 http://dx.doi.org/10.4103/jpbs.jpbs_157_23 Text en Copyright: © 2023 Journal of Pharmacy and Bioallied Sciences https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Langaliya, Akshayraj Kothari, Anjali Buch, Aastha Dave, Riya Shah, Jinali Shah, Nishtha Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems—An In vitro Study |
title | Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems—An In vitro Study |
title_full | Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems—An In vitro Study |
title_fullStr | Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems—An In vitro Study |
title_full_unstemmed | Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems—An In vitro Study |
title_short | Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems—An In vitro Study |
title_sort | comparative evaluation of root canal transportation and centering ability in curved mesiobuccal canals of mandibular first molars after instrumentation with different file systems—an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10485439/ https://www.ncbi.nlm.nih.gov/pubmed/37694024 http://dx.doi.org/10.4103/jpbs.jpbs_157_23 |
work_keys_str_mv | AT langaliyaakshayraj comparativeevaluationofrootcanaltransportationandcenteringabilityincurvedmesiobuccalcanalsofmandibularfirstmolarsafterinstrumentationwithdifferentfilesystemsaninvitrostudy AT kotharianjali comparativeevaluationofrootcanaltransportationandcenteringabilityincurvedmesiobuccalcanalsofmandibularfirstmolarsafterinstrumentationwithdifferentfilesystemsaninvitrostudy AT buchaastha comparativeevaluationofrootcanaltransportationandcenteringabilityincurvedmesiobuccalcanalsofmandibularfirstmolarsafterinstrumentationwithdifferentfilesystemsaninvitrostudy AT daveriya comparativeevaluationofrootcanaltransportationandcenteringabilityincurvedmesiobuccalcanalsofmandibularfirstmolarsafterinstrumentationwithdifferentfilesystemsaninvitrostudy AT shahjinali comparativeevaluationofrootcanaltransportationandcenteringabilityincurvedmesiobuccalcanalsofmandibularfirstmolarsafterinstrumentationwithdifferentfilesystemsaninvitrostudy AT shahnishtha comparativeevaluationofrootcanaltransportationandcenteringabilityincurvedmesiobuccalcanalsofmandibularfirstmolarsafterinstrumentationwithdifferentfilesystemsaninvitrostudy |