Cargando…

Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification

FEATURED APPLICATION: Ultrasound scores should consider that some frequent masses such as fibromas, cystoadenofibromas, some mucinous cystadenomas and Brenner tumors may present some characteristics that induce confusion with malignant lesions. Some malignant lesions are not always identified as mal...

Descripción completa

Detalles Bibliográficos
Autores principales: Pelayo, Mar, Sancho-Sauco, Javier, Sánchez-Zurdo, Javier, Perez-Mies, Belén, Abarca-Martínez, Leopoldo, Cancelo-Hidalgo, Mª Jesús, Sainz-Bueno, Jose Antonio, Alcázar, Juan Luis, Pelayo-Delgado, Irene
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10486436/
https://www.ncbi.nlm.nih.gov/pubmed/37685323
http://dx.doi.org/10.3390/diagnostics13172785
_version_ 1785103006285430784
author Pelayo, Mar
Sancho-Sauco, Javier
Sánchez-Zurdo, Javier
Perez-Mies, Belén
Abarca-Martínez, Leopoldo
Cancelo-Hidalgo, Mª Jesús
Sainz-Bueno, Jose Antonio
Alcázar, Juan Luis
Pelayo-Delgado, Irene
author_facet Pelayo, Mar
Sancho-Sauco, Javier
Sánchez-Zurdo, Javier
Perez-Mies, Belén
Abarca-Martínez, Leopoldo
Cancelo-Hidalgo, Mª Jesús
Sainz-Bueno, Jose Antonio
Alcázar, Juan Luis
Pelayo-Delgado, Irene
author_sort Pelayo, Mar
collection PubMed
description FEATURED APPLICATION: Ultrasound scores should consider that some frequent masses such as fibromas, cystoadenofibromas, some mucinous cystadenomas and Brenner tumors may present some characteristics that induce confusion with malignant lesions. Some malignant lesions are not always identified as malignant. ABSTRACT: Background: Ultrasound features help to differentiate benign from malignant masses, and some of them are included in the ultrasound (US) scores. The main aim of this work is to describe the ultrasound features of certain adnexal masses of difficult classification and to analyse them according to the most frequently used US scores. Methods: Retrospective studies of adnexal lesions are difficult to classify by US scores in women undergoing surgery. Ultrasound characteristics were analysed, and masses were classified according to the Subjective Assessment of the ultrasonographer (SA) and other US scores (IOTA Simple Rules Risk Assessment-SRRA, ADNEX model with and without CA125 and O-RADS). Results: A total of 133 adnexal masses were studied (benign: 66.2%, n:88; malignant: 33.8%, n:45) in a sample of women with mean age 56.5 ± 7.8 years. Malignant lesions were identified by SA in all cases. Borderline ovarian tumors (n:13) were not always detected by some US scores (SRRA: 76.9%, ADNEX model without and with CA125: 76.9% and 84.6%) nor were serous carcinoma (n:19) (SRRA: 89.5%), clear cell carcinoma (n:9) (SRRA: 66.7%) or endometrioid carcinoma (n:4) (ADNEX model without CA125: 75.0%). While most teratomas and serous cystadenomas have been correctly differentiated, other benign lesions were misclassified because of the presence of solid areas or papillae. Fibromas (n:13) were better identified by SA (23.1% malignancy), but worse with the other US scores (SRRA: 69.2%, ADNEX model without and with CA125: 84.6% and 69.2%, O-RADS: 53.8%). Cystoadenofibromas (n:10) were difficult to distinguish from malignant masses via all scores except SRRA (SA: 70.0%, SRRA: 20.0%, ADNEX model without and with CA125: 60.0% and 50.0%, O-RADS: 90.0%). Mucinous cystadenomas (n:12) were misdiagnosed as malignant in more than 15% of the cases in all US scores (SA: 33.3%, SRRA: 16.7%, ADNEX model without and with CA125: 16.7% and 16.7%, O-RADS:41.7%). Brenner tumors are also difficult to classify using all scores. Conclusion: Some malignant masses (borderline ovarian tumors, serous carcinoma, clear cell carcinoma, endometrioid carcinomas) are not always detected by US scores. Fibromas, cystoadenofibromas, some mucinous cystadenomas and Brenner tumors may present solid components/papillae that may induce confusion with malignant lesions. Most teratomas and serous cystadenomas are usually correctly classified.
format Online
Article
Text
id pubmed-10486436
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104864362023-09-09 Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification Pelayo, Mar Sancho-Sauco, Javier Sánchez-Zurdo, Javier Perez-Mies, Belén Abarca-Martínez, Leopoldo Cancelo-Hidalgo, Mª Jesús Sainz-Bueno, Jose Antonio Alcázar, Juan Luis Pelayo-Delgado, Irene Diagnostics (Basel) Article FEATURED APPLICATION: Ultrasound scores should consider that some frequent masses such as fibromas, cystoadenofibromas, some mucinous cystadenomas and Brenner tumors may present some characteristics that induce confusion with malignant lesions. Some malignant lesions are not always identified as malignant. ABSTRACT: Background: Ultrasound features help to differentiate benign from malignant masses, and some of them are included in the ultrasound (US) scores. The main aim of this work is to describe the ultrasound features of certain adnexal masses of difficult classification and to analyse them according to the most frequently used US scores. Methods: Retrospective studies of adnexal lesions are difficult to classify by US scores in women undergoing surgery. Ultrasound characteristics were analysed, and masses were classified according to the Subjective Assessment of the ultrasonographer (SA) and other US scores (IOTA Simple Rules Risk Assessment-SRRA, ADNEX model with and without CA125 and O-RADS). Results: A total of 133 adnexal masses were studied (benign: 66.2%, n:88; malignant: 33.8%, n:45) in a sample of women with mean age 56.5 ± 7.8 years. Malignant lesions were identified by SA in all cases. Borderline ovarian tumors (n:13) were not always detected by some US scores (SRRA: 76.9%, ADNEX model without and with CA125: 76.9% and 84.6%) nor were serous carcinoma (n:19) (SRRA: 89.5%), clear cell carcinoma (n:9) (SRRA: 66.7%) or endometrioid carcinoma (n:4) (ADNEX model without CA125: 75.0%). While most teratomas and serous cystadenomas have been correctly differentiated, other benign lesions were misclassified because of the presence of solid areas or papillae. Fibromas (n:13) were better identified by SA (23.1% malignancy), but worse with the other US scores (SRRA: 69.2%, ADNEX model without and with CA125: 84.6% and 69.2%, O-RADS: 53.8%). Cystoadenofibromas (n:10) were difficult to distinguish from malignant masses via all scores except SRRA (SA: 70.0%, SRRA: 20.0%, ADNEX model without and with CA125: 60.0% and 50.0%, O-RADS: 90.0%). Mucinous cystadenomas (n:12) were misdiagnosed as malignant in more than 15% of the cases in all US scores (SA: 33.3%, SRRA: 16.7%, ADNEX model without and with CA125: 16.7% and 16.7%, O-RADS:41.7%). Brenner tumors are also difficult to classify using all scores. Conclusion: Some malignant masses (borderline ovarian tumors, serous carcinoma, clear cell carcinoma, endometrioid carcinomas) are not always detected by US scores. Fibromas, cystoadenofibromas, some mucinous cystadenomas and Brenner tumors may present solid components/papillae that may induce confusion with malignant lesions. Most teratomas and serous cystadenomas are usually correctly classified. MDPI 2023-08-28 /pmc/articles/PMC10486436/ /pubmed/37685323 http://dx.doi.org/10.3390/diagnostics13172785 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pelayo, Mar
Sancho-Sauco, Javier
Sánchez-Zurdo, Javier
Perez-Mies, Belén
Abarca-Martínez, Leopoldo
Cancelo-Hidalgo, Mª Jesús
Sainz-Bueno, Jose Antonio
Alcázar, Juan Luis
Pelayo-Delgado, Irene
Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification
title Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification
title_full Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification
title_fullStr Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification
title_full_unstemmed Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification
title_short Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification
title_sort application of ultrasound scores (subjective assessment, simple rules risk assessment, adnex model, o-rads) to adnexal masses of difficult classification
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10486436/
https://www.ncbi.nlm.nih.gov/pubmed/37685323
http://dx.doi.org/10.3390/diagnostics13172785
work_keys_str_mv AT pelayomar applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification
AT sanchosaucojavier applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification
AT sanchezzurdojavier applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification
AT perezmiesbelen applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification
AT abarcamartinezleopoldo applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification
AT cancelohidalgomajesus applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification
AT sainzbuenojoseantonio applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification
AT alcazarjuanluis applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification
AT pelayodelgadoirene applicationofultrasoundscoressubjectiveassessmentsimplerulesriskassessmentadnexmodeloradstoadnexalmassesofdifficultclassification