Cargando…

Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study

OBJECTIVES: Stroke volume (SV) and cardiac output monitoring is a cornerstone of hemodynamic assessment. Noninvasive technologies are increasingly used in children. This study compared SV measurements obtained by transcutaneous Doppler ultrasound techniques (ultrasonic cardiac output monitor [USCOM]...

Descripción completa

Detalles Bibliográficos
Autores principales: Fremuth, Jiri, Huml, Michal, Pomahacova, Tereza, Kobr, Jiri, Kormunda, Stanislav, Sykora, Josef
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10487356/
https://www.ncbi.nlm.nih.gov/pubmed/37478016
http://dx.doi.org/10.1097/PEC.0000000000003018
_version_ 1785103219499728896
author Fremuth, Jiri
Huml, Michal
Pomahacova, Tereza
Kobr, Jiri
Kormunda, Stanislav
Sykora, Josef
author_facet Fremuth, Jiri
Huml, Michal
Pomahacova, Tereza
Kobr, Jiri
Kormunda, Stanislav
Sykora, Josef
author_sort Fremuth, Jiri
collection PubMed
description OBJECTIVES: Stroke volume (SV) and cardiac output monitoring is a cornerstone of hemodynamic assessment. Noninvasive technologies are increasingly used in children. This study compared SV measurements obtained by transcutaneous Doppler ultrasound techniques (ultrasonic cardiac output monitor [USCOM]), transthoracic echocardiography jugular (TTE-J), and parasternal (TTE-P) views performed by pediatric intensivists (OP-As) with limited training in cardiac sonography (20 previous examinations) and pediatric cardiologists (OP-Bs) with limited training in USCOM (30 previous examinations) in spontaneously ventilating children. METHODS: A single-center study was conducted in 37 children. Each operator obtained 3 sets of USCOM SV measurements within a period of 3 to 5 minutes, followed with TTE measurements from both apical and jugular views. The investigators were blinded to each other's results to prevent visual and auditory bias. RESULTS: Both USCOM and TTE methods were applicable in 89% of patients. The intraobserver variability of USCOM, TTE-J, and TTE-P were less than 10% in both investigators. The SV measurements by OP-As using USCOM, TTE-J, and TTE-P were 46.15 (25.48) mL, 39.45 (20.65) mL, and 33.42 (16.69) mL, respectively. The SV measurements by OP-Bs using USCOM, TTE-J, and TTE-P were 43.99 (25.24) mL, 38.91 (19.98) mL, and 37.58 (19.81) mL, respectively. The percentage error in SV with USCOM relative to TTE-J was 36% in OP-As and 37% in OP-Bs. The percentage error in SV with TTE-P was 33% relative to TTE-J in OP-As and 21% in OP-Bs. CONCLUSIONS: Our findings show that the methods are not interchangeable because SV values by USCOM are higher in comparison with the SV values obtained by TTE. Both methods have low level of intraobserver variability. The SV measurements obtained by TTE-P were significantly lower compared with the TTE-J for the operator with limited training in echocardiography. The TTE-P requires longer practice compared with the TTE-J; therefore, we recommend to prefer TTE-J to TTE-P for inexperienced operators.
format Online
Article
Text
id pubmed-10487356
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-104873562023-09-09 Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study Fremuth, Jiri Huml, Michal Pomahacova, Tereza Kobr, Jiri Kormunda, Stanislav Sykora, Josef Pediatr Emerg Care Original Articles OBJECTIVES: Stroke volume (SV) and cardiac output monitoring is a cornerstone of hemodynamic assessment. Noninvasive technologies are increasingly used in children. This study compared SV measurements obtained by transcutaneous Doppler ultrasound techniques (ultrasonic cardiac output monitor [USCOM]), transthoracic echocardiography jugular (TTE-J), and parasternal (TTE-P) views performed by pediatric intensivists (OP-As) with limited training in cardiac sonography (20 previous examinations) and pediatric cardiologists (OP-Bs) with limited training in USCOM (30 previous examinations) in spontaneously ventilating children. METHODS: A single-center study was conducted in 37 children. Each operator obtained 3 sets of USCOM SV measurements within a period of 3 to 5 minutes, followed with TTE measurements from both apical and jugular views. The investigators were blinded to each other's results to prevent visual and auditory bias. RESULTS: Both USCOM and TTE methods were applicable in 89% of patients. The intraobserver variability of USCOM, TTE-J, and TTE-P were less than 10% in both investigators. The SV measurements by OP-As using USCOM, TTE-J, and TTE-P were 46.15 (25.48) mL, 39.45 (20.65) mL, and 33.42 (16.69) mL, respectively. The SV measurements by OP-Bs using USCOM, TTE-J, and TTE-P were 43.99 (25.24) mL, 38.91 (19.98) mL, and 37.58 (19.81) mL, respectively. The percentage error in SV with USCOM relative to TTE-J was 36% in OP-As and 37% in OP-Bs. The percentage error in SV with TTE-P was 33% relative to TTE-J in OP-As and 21% in OP-Bs. CONCLUSIONS: Our findings show that the methods are not interchangeable because SV values by USCOM are higher in comparison with the SV values obtained by TTE. Both methods have low level of intraobserver variability. The SV measurements obtained by TTE-P were significantly lower compared with the TTE-J for the operator with limited training in echocardiography. The TTE-P requires longer practice compared with the TTE-J; therefore, we recommend to prefer TTE-J to TTE-P for inexperienced operators. Lippincott Williams & Wilkins 2023-09 2023-07-22 /pmc/articles/PMC10487356/ /pubmed/37478016 http://dx.doi.org/10.1097/PEC.0000000000003018 Text en Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Fremuth, Jiri
Huml, Michal
Pomahacova, Tereza
Kobr, Jiri
Kormunda, Stanislav
Sykora, Josef
Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
title Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
title_full Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
title_fullStr Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
title_full_unstemmed Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
title_short Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
title_sort stroke volume measurements by echocardiography and ultrasonic cardiac output monitor in children: a prospective observational cohort study
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10487356/
https://www.ncbi.nlm.nih.gov/pubmed/37478016
http://dx.doi.org/10.1097/PEC.0000000000003018
work_keys_str_mv AT fremuthjiri strokevolumemeasurementsbyechocardiographyandultrasoniccardiacoutputmonitorinchildrenaprospectiveobservationalcohortstudy
AT humlmichal strokevolumemeasurementsbyechocardiographyandultrasoniccardiacoutputmonitorinchildrenaprospectiveobservationalcohortstudy
AT pomahacovatereza strokevolumemeasurementsbyechocardiographyandultrasoniccardiacoutputmonitorinchildrenaprospectiveobservationalcohortstudy
AT kobrjiri strokevolumemeasurementsbyechocardiographyandultrasoniccardiacoutputmonitorinchildrenaprospectiveobservationalcohortstudy
AT kormundastanislav strokevolumemeasurementsbyechocardiographyandultrasoniccardiacoutputmonitorinchildrenaprospectiveobservationalcohortstudy
AT sykorajosef strokevolumemeasurementsbyechocardiographyandultrasoniccardiacoutputmonitorinchildrenaprospectiveobservationalcohortstudy