Cargando…

Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study

New technologies based on virtual reality and augmented reality offer promising perspectives in an attempt to increase the assessment of human kinematics. The aim of this work was to develop a markerless 3D motion analysis capture system (MOVA3D) and to test it versus Qualisys Track Manager (QTM). A...

Descripción completa

Detalles Bibliográficos
Autores principales: de Almeida, Liliane Pinho, Guenka, Leandro Caetano, Felipe, Danielle de Oliveira, Ishii, Renato Porfirio, de Campos, Pedro Senna, Burke, Thomaz Nogueira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10488120/
https://www.ncbi.nlm.nih.gov/pubmed/37681796
http://dx.doi.org/10.3390/ijerph20176657
_version_ 1785103403523768320
author de Almeida, Liliane Pinho
Guenka, Leandro Caetano
Felipe, Danielle de Oliveira
Ishii, Renato Porfirio
de Campos, Pedro Senna
Burke, Thomaz Nogueira
author_facet de Almeida, Liliane Pinho
Guenka, Leandro Caetano
Felipe, Danielle de Oliveira
Ishii, Renato Porfirio
de Campos, Pedro Senna
Burke, Thomaz Nogueira
author_sort de Almeida, Liliane Pinho
collection PubMed
description New technologies based on virtual reality and augmented reality offer promising perspectives in an attempt to increase the assessment of human kinematics. The aim of this work was to develop a markerless 3D motion analysis capture system (MOVA3D) and to test it versus Qualisys Track Manager (QTM). A digital camera was used to capture the data, and proprietary software capable of automatically inferring the joint centers in 3D and performing the angular kinematic calculations of interest was developed for such analysis. In the experiment, 10 subjects (22 to 50 years old), 5 men and 5 women, with a body mass index between 18.5 and 29.9 kg/m(2), performed squatting, hip flexion, and abduction movements, and both systems measured the hip abduction/adduction angle and hip flexion/extension, simultaneously. The mean value of the difference between the QTM system and the MOVA3D system for all frames for each joint angle was analyzed with Pearson’s correlation coefficient (r). The MOVA3D system reached good (above 0.75) or excellent (above 0.90) correlations in 6 out of 8 variables. The average error remained below 12° in only 20 out of 24 variables analyzed. The MOVA3D system is therefore promising for use in telerehabilitation or other applications where this level of error is acceptable. Future studies should continue to validate the MOVA3D as updated versions of their software are developed.
format Online
Article
Text
id pubmed-10488120
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104881202023-09-09 Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study de Almeida, Liliane Pinho Guenka, Leandro Caetano Felipe, Danielle de Oliveira Ishii, Renato Porfirio de Campos, Pedro Senna Burke, Thomaz Nogueira Int J Environ Res Public Health Article New technologies based on virtual reality and augmented reality offer promising perspectives in an attempt to increase the assessment of human kinematics. The aim of this work was to develop a markerless 3D motion analysis capture system (MOVA3D) and to test it versus Qualisys Track Manager (QTM). A digital camera was used to capture the data, and proprietary software capable of automatically inferring the joint centers in 3D and performing the angular kinematic calculations of interest was developed for such analysis. In the experiment, 10 subjects (22 to 50 years old), 5 men and 5 women, with a body mass index between 18.5 and 29.9 kg/m(2), performed squatting, hip flexion, and abduction movements, and both systems measured the hip abduction/adduction angle and hip flexion/extension, simultaneously. The mean value of the difference between the QTM system and the MOVA3D system for all frames for each joint angle was analyzed with Pearson’s correlation coefficient (r). The MOVA3D system reached good (above 0.75) or excellent (above 0.90) correlations in 6 out of 8 variables. The average error remained below 12° in only 20 out of 24 variables analyzed. The MOVA3D system is therefore promising for use in telerehabilitation or other applications where this level of error is acceptable. Future studies should continue to validate the MOVA3D as updated versions of their software are developed. MDPI 2023-08-26 /pmc/articles/PMC10488120/ /pubmed/37681796 http://dx.doi.org/10.3390/ijerph20176657 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
de Almeida, Liliane Pinho
Guenka, Leandro Caetano
Felipe, Danielle de Oliveira
Ishii, Renato Porfirio
de Campos, Pedro Senna
Burke, Thomaz Nogueira
Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study
title Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study
title_full Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study
title_fullStr Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study
title_full_unstemmed Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study
title_short Correlation between MOVA3D, a Monocular Movement Analysis System, and Qualisys Track Manager (QTM) during Lower Limb Movements in Healthy Adults: A Preliminary Study
title_sort correlation between mova3d, a monocular movement analysis system, and qualisys track manager (qtm) during lower limb movements in healthy adults: a preliminary study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10488120/
https://www.ncbi.nlm.nih.gov/pubmed/37681796
http://dx.doi.org/10.3390/ijerph20176657
work_keys_str_mv AT dealmeidalilianepinho correlationbetweenmova3damonocularmovementanalysissystemandqualisystrackmanagerqtmduringlowerlimbmovementsinhealthyadultsapreliminarystudy
AT guenkaleandrocaetano correlationbetweenmova3damonocularmovementanalysissystemandqualisystrackmanagerqtmduringlowerlimbmovementsinhealthyadultsapreliminarystudy
AT felipedanielledeoliveira correlationbetweenmova3damonocularmovementanalysissystemandqualisystrackmanagerqtmduringlowerlimbmovementsinhealthyadultsapreliminarystudy
AT ishiirenatoporfirio correlationbetweenmova3damonocularmovementanalysissystemandqualisystrackmanagerqtmduringlowerlimbmovementsinhealthyadultsapreliminarystudy
AT decampospedrosenna correlationbetweenmova3damonocularmovementanalysissystemandqualisystrackmanagerqtmduringlowerlimbmovementsinhealthyadultsapreliminarystudy
AT burkethomaznogueira correlationbetweenmova3damonocularmovementanalysissystemandqualisystrackmanagerqtmduringlowerlimbmovementsinhealthyadultsapreliminarystudy