Cargando…

FEM Simulations of Fatigue Crack Initiation in the Oligocrystalline Microstructure of Stents

For over two decades, vascular stents have been widely used to treat clogged vessels, serving as a scaffold to enlarge the narrowed lumen and recover the arterial flow area. High-purity oligocrystalline austenitic steel is usually applied for the production of stents. Despite the popularity and bene...

Descripción completa

Detalles Bibliográficos
Autores principales: Lasko, Galina, Schmauder, Siegfried, Yang, Yitong, Weiss, Sabine, Dogahe, Kiarash
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10488850/
https://www.ncbi.nlm.nih.gov/pubmed/37687693
http://dx.doi.org/10.3390/ma16176003
_version_ 1785103574458433536
author Lasko, Galina
Schmauder, Siegfried
Yang, Yitong
Weiss, Sabine
Dogahe, Kiarash
author_facet Lasko, Galina
Schmauder, Siegfried
Yang, Yitong
Weiss, Sabine
Dogahe, Kiarash
author_sort Lasko, Galina
collection PubMed
description For over two decades, vascular stents have been widely used to treat clogged vessels, serving as a scaffold to enlarge the narrowed lumen and recover the arterial flow area. High-purity oligocrystalline austenitic steel is usually applied for the production of stents. Despite the popularity and benefit of stenting, it still may cause serious clinical adverse issues, such as in-stent restenosis and stent fracture. Therefore, the study of the mechanical properties of stents and in particular the prediction of their life cycles are in the focus of materials research. In our contribution, within the finite element method, a two-scale model of crack initiation in the microstructure of stents is elaborated. The approach is developed on the basis of the physically based Tanaka–Mura model (TMM), considering the evolution of shear bands during the crack initiation phase. The model allows for the analysis of the microstructure with respect to the life cycles of real materials. The effects of different loading conditions, grain orientation, and thickness of the specimen on Wöhler curves were analysed. It was found that the microstructural features of oligocrystals are very sensitive to different loading conditions with respect to their fatigue behaviour and play a major role in fatigue crack initiation. Different grain-orientation distributions result in qualitative and quantitative differences in stress distribution and in the number of cycles for crack initiation. It was found that presence of a neutral zone in the cut-out of the microstructure under three-point-bending loading conditions changes the qualitative and quantitative patterns of stress distribution and affects the number of cycles for crack initiation. It was found that under both tensile and bending loading conditions, thicker specimens require more cycles for crack initiation. The Wöhler curves for crack initiation in oligocrystalline microstructures of stents could be compared with the ones in the experiment, taking into account that for high cyclic fatigue (HCF), typically, more than 70% of the cycles refer to crack initiation. The developed numerical tools could be used for the material design of stents.
format Online
Article
Text
id pubmed-10488850
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104888502023-09-09 FEM Simulations of Fatigue Crack Initiation in the Oligocrystalline Microstructure of Stents Lasko, Galina Schmauder, Siegfried Yang, Yitong Weiss, Sabine Dogahe, Kiarash Materials (Basel) Article For over two decades, vascular stents have been widely used to treat clogged vessels, serving as a scaffold to enlarge the narrowed lumen and recover the arterial flow area. High-purity oligocrystalline austenitic steel is usually applied for the production of stents. Despite the popularity and benefit of stenting, it still may cause serious clinical adverse issues, such as in-stent restenosis and stent fracture. Therefore, the study of the mechanical properties of stents and in particular the prediction of their life cycles are in the focus of materials research. In our contribution, within the finite element method, a two-scale model of crack initiation in the microstructure of stents is elaborated. The approach is developed on the basis of the physically based Tanaka–Mura model (TMM), considering the evolution of shear bands during the crack initiation phase. The model allows for the analysis of the microstructure with respect to the life cycles of real materials. The effects of different loading conditions, grain orientation, and thickness of the specimen on Wöhler curves were analysed. It was found that the microstructural features of oligocrystals are very sensitive to different loading conditions with respect to their fatigue behaviour and play a major role in fatigue crack initiation. Different grain-orientation distributions result in qualitative and quantitative differences in stress distribution and in the number of cycles for crack initiation. It was found that presence of a neutral zone in the cut-out of the microstructure under three-point-bending loading conditions changes the qualitative and quantitative patterns of stress distribution and affects the number of cycles for crack initiation. It was found that under both tensile and bending loading conditions, thicker specimens require more cycles for crack initiation. The Wöhler curves for crack initiation in oligocrystalline microstructures of stents could be compared with the ones in the experiment, taking into account that for high cyclic fatigue (HCF), typically, more than 70% of the cycles refer to crack initiation. The developed numerical tools could be used for the material design of stents. MDPI 2023-08-31 /pmc/articles/PMC10488850/ /pubmed/37687693 http://dx.doi.org/10.3390/ma16176003 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lasko, Galina
Schmauder, Siegfried
Yang, Yitong
Weiss, Sabine
Dogahe, Kiarash
FEM Simulations of Fatigue Crack Initiation in the Oligocrystalline Microstructure of Stents
title FEM Simulations of Fatigue Crack Initiation in the Oligocrystalline Microstructure of Stents
title_full FEM Simulations of Fatigue Crack Initiation in the Oligocrystalline Microstructure of Stents
title_fullStr FEM Simulations of Fatigue Crack Initiation in the Oligocrystalline Microstructure of Stents
title_full_unstemmed FEM Simulations of Fatigue Crack Initiation in the Oligocrystalline Microstructure of Stents
title_short FEM Simulations of Fatigue Crack Initiation in the Oligocrystalline Microstructure of Stents
title_sort fem simulations of fatigue crack initiation in the oligocrystalline microstructure of stents
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10488850/
https://www.ncbi.nlm.nih.gov/pubmed/37687693
http://dx.doi.org/10.3390/ma16176003
work_keys_str_mv AT laskogalina femsimulationsoffatiguecrackinitiationintheoligocrystallinemicrostructureofstents
AT schmaudersiegfried femsimulationsoffatiguecrackinitiationintheoligocrystallinemicrostructureofstents
AT yangyitong femsimulationsoffatiguecrackinitiationintheoligocrystallinemicrostructureofstents
AT weisssabine femsimulationsoffatiguecrackinitiationintheoligocrystallinemicrostructureofstents
AT dogahekiarash femsimulationsoffatiguecrackinitiationintheoligocrystallinemicrostructureofstents