Cargando…

Comparative Studies of the Confined Effect of Shear Masonry Walls Made of Autoclaved Aerated Concrete Masonry Units

Confined walls are popular in areas exposed to seismic action. The advantage of such structures is increased load-bearing capacity, ductility, and energy dissipation. Confined masonry walls are also used to restrain the intensity of cracking and improve load-bearing capacity in areas exposed to seis...

Descripción completa

Detalles Bibliográficos
Autores principales: Jasiński, Radosław, Gąsiorowski, Tomasz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10488920/
https://www.ncbi.nlm.nih.gov/pubmed/37687577
http://dx.doi.org/10.3390/ma16175885
_version_ 1785103590505840640
author Jasiński, Radosław
Gąsiorowski, Tomasz
author_facet Jasiński, Radosław
Gąsiorowski, Tomasz
author_sort Jasiński, Radosław
collection PubMed
description Confined walls are popular in areas exposed to seismic action. The advantage of such structures is increased load-bearing capacity, ductility, and energy dissipation. Confined masonry walls are also used to restrain the intensity of cracking and improve load-bearing capacity in areas exposed to seismic action. This paper describes the research on 18 confined walls and presents a comparison with research on unconfined walls (referenced models). The confined models were classified into three series: HOS-C-AAC—without openings and with confining elements around the perimeter; HAS-C1-AAC with a centrally positioned opening and circumferential confinement; and HAS-C2-AAC with a centrally positioned window opening and additional confinement along the vertical edges of the opening. The area of the window opening was 1.5 m(2). All walls were made of autoclaved aerated concrete (AAC) masonry units of the nominal density class of 600. The walls were tested under initial compressive stresses σ(c) = 0.1; 0.75; and 1.0 N/mm(2). The reference models without confinement (six models of the series HOS-AAC without openings and the series HAS-AAC with openings) were prepared from the same masonry units, had almost the same outer dimensions, and were tested under the same initial compressive stresses σ(c). The analysis was performed for the morphology of cracks, stress values at the moment of cracking and failure, stiffness, and angles of shear strain. The morphology of cracks was found to depend on initial compressive stresses and the presence of an opening. A significant increase in compressive stress leading to cracks and failure stresses was observed with increasing values of initial compressive stresses. As the wall behavior was clearly non-linear, the bilinear relationship described by energy dissipation E, stiffness at the moment of cracking K(cr), and maximum displacement u(u) was proposed to be included in the engineering description of the relationship between horizontal load and displacement of confined walls. Confinement along the vertical edges of the opening having an area of 1.5 m(2) (acc. to EN 1996-1-1) increased the maximum forces P(max) by ca. 45% and marginally affected the ductility of the wall when compared to the elements with circumferential confinement.
format Online
Article
Text
id pubmed-10488920
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104889202023-09-09 Comparative Studies of the Confined Effect of Shear Masonry Walls Made of Autoclaved Aerated Concrete Masonry Units Jasiński, Radosław Gąsiorowski, Tomasz Materials (Basel) Article Confined walls are popular in areas exposed to seismic action. The advantage of such structures is increased load-bearing capacity, ductility, and energy dissipation. Confined masonry walls are also used to restrain the intensity of cracking and improve load-bearing capacity in areas exposed to seismic action. This paper describes the research on 18 confined walls and presents a comparison with research on unconfined walls (referenced models). The confined models were classified into three series: HOS-C-AAC—without openings and with confining elements around the perimeter; HAS-C1-AAC with a centrally positioned opening and circumferential confinement; and HAS-C2-AAC with a centrally positioned window opening and additional confinement along the vertical edges of the opening. The area of the window opening was 1.5 m(2). All walls were made of autoclaved aerated concrete (AAC) masonry units of the nominal density class of 600. The walls were tested under initial compressive stresses σ(c) = 0.1; 0.75; and 1.0 N/mm(2). The reference models without confinement (six models of the series HOS-AAC without openings and the series HAS-AAC with openings) were prepared from the same masonry units, had almost the same outer dimensions, and were tested under the same initial compressive stresses σ(c). The analysis was performed for the morphology of cracks, stress values at the moment of cracking and failure, stiffness, and angles of shear strain. The morphology of cracks was found to depend on initial compressive stresses and the presence of an opening. A significant increase in compressive stress leading to cracks and failure stresses was observed with increasing values of initial compressive stresses. As the wall behavior was clearly non-linear, the bilinear relationship described by energy dissipation E, stiffness at the moment of cracking K(cr), and maximum displacement u(u) was proposed to be included in the engineering description of the relationship between horizontal load and displacement of confined walls. Confinement along the vertical edges of the opening having an area of 1.5 m(2) (acc. to EN 1996-1-1) increased the maximum forces P(max) by ca. 45% and marginally affected the ductility of the wall when compared to the elements with circumferential confinement. MDPI 2023-08-28 /pmc/articles/PMC10488920/ /pubmed/37687577 http://dx.doi.org/10.3390/ma16175885 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jasiński, Radosław
Gąsiorowski, Tomasz
Comparative Studies of the Confined Effect of Shear Masonry Walls Made of Autoclaved Aerated Concrete Masonry Units
title Comparative Studies of the Confined Effect of Shear Masonry Walls Made of Autoclaved Aerated Concrete Masonry Units
title_full Comparative Studies of the Confined Effect of Shear Masonry Walls Made of Autoclaved Aerated Concrete Masonry Units
title_fullStr Comparative Studies of the Confined Effect of Shear Masonry Walls Made of Autoclaved Aerated Concrete Masonry Units
title_full_unstemmed Comparative Studies of the Confined Effect of Shear Masonry Walls Made of Autoclaved Aerated Concrete Masonry Units
title_short Comparative Studies of the Confined Effect of Shear Masonry Walls Made of Autoclaved Aerated Concrete Masonry Units
title_sort comparative studies of the confined effect of shear masonry walls made of autoclaved aerated concrete masonry units
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10488920/
https://www.ncbi.nlm.nih.gov/pubmed/37687577
http://dx.doi.org/10.3390/ma16175885
work_keys_str_mv AT jasinskiradosław comparativestudiesoftheconfinedeffectofshearmasonrywallsmadeofautoclavedaeratedconcretemasonryunits
AT gasiorowskitomasz comparativestudiesoftheconfinedeffectofshearmasonrywallsmadeofautoclavedaeratedconcretemasonryunits