Cargando…

One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk

Implantable cardioverter defibrillators (ICDs) significantly contribute to the prevention of sudden cardiac death in selected patients. However, it is essential to identify those who are likely to not have benefit from an ICD and to defer a pulse generator exchange. Easily implementable guidelines f...

Descripción completa

Detalles Bibliográficos
Autores principales: Feijen, Michelle, Egorova, Anastasia D., Kuijken, Teresa, Bootsma, Marianne, Schalij, Martin J., van Erven, Lieselot
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10489035/
https://www.ncbi.nlm.nih.gov/pubmed/37685719
http://dx.doi.org/10.3390/jcm12175654
_version_ 1785103617298006016
author Feijen, Michelle
Egorova, Anastasia D.
Kuijken, Teresa
Bootsma, Marianne
Schalij, Martin J.
van Erven, Lieselot
author_facet Feijen, Michelle
Egorova, Anastasia D.
Kuijken, Teresa
Bootsma, Marianne
Schalij, Martin J.
van Erven, Lieselot
author_sort Feijen, Michelle
collection PubMed
description Implantable cardioverter defibrillators (ICDs) significantly contribute to the prevention of sudden cardiac death in selected patients. However, it is essential to identify those who are likely to not have benefit from an ICD and to defer a pulse generator exchange. Easily implementable guidelines for individual risk stratification and decision making are lacking. This study investigates the 1-year mortality of patients who underwent an ICD or cardiac resynchronization therapy with defibrillator function (CRT-D) pulse generator replacement in a contemporary real-world tertiary hospital setting. The cause of death and patient- and procedure-related factors are stratified, and predictive values for 1-year mortality are evaluated. Patients with a follow-up of ≥365 days (or prior mortality) after an ICD or CRT-D exchange at the Leiden University Medical Center from 1 January 2018 until 31 December 2021 were eligible. In total, 588 patients were included (77% male, 69 [60–76] years old, 59% primary prevention, 46% ischemic cardiomyopathy and 37% mildly reduced left ventricular ejection fraction (LVEF)). Patients undergoing a CRT-D replacement or upgrade had a significantly higher 1-year all-cause mortality (10.7% and 11.9%, respectively) compared to patients undergoing ICD (2.8%) exchange (p = 0.002). LVEF ≤ 30%, New York Heart Association class ≥ 3, estimated glomerular filtration rate ≤ 30 mL/min/m(2) and haemoglobin ≤ 7 mmol/L were independently associated with mortality within 1 year after pulse generator replacement. There is a growing need for prospectively validated risk scores to weight individualized risk of mortality with the expected ICD therapy benefit and to support a well-informed, shared decision-making process.
format Online
Article
Text
id pubmed-10489035
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104890352023-09-09 One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk Feijen, Michelle Egorova, Anastasia D. Kuijken, Teresa Bootsma, Marianne Schalij, Martin J. van Erven, Lieselot J Clin Med Article Implantable cardioverter defibrillators (ICDs) significantly contribute to the prevention of sudden cardiac death in selected patients. However, it is essential to identify those who are likely to not have benefit from an ICD and to defer a pulse generator exchange. Easily implementable guidelines for individual risk stratification and decision making are lacking. This study investigates the 1-year mortality of patients who underwent an ICD or cardiac resynchronization therapy with defibrillator function (CRT-D) pulse generator replacement in a contemporary real-world tertiary hospital setting. The cause of death and patient- and procedure-related factors are stratified, and predictive values for 1-year mortality are evaluated. Patients with a follow-up of ≥365 days (or prior mortality) after an ICD or CRT-D exchange at the Leiden University Medical Center from 1 January 2018 until 31 December 2021 were eligible. In total, 588 patients were included (77% male, 69 [60–76] years old, 59% primary prevention, 46% ischemic cardiomyopathy and 37% mildly reduced left ventricular ejection fraction (LVEF)). Patients undergoing a CRT-D replacement or upgrade had a significantly higher 1-year all-cause mortality (10.7% and 11.9%, respectively) compared to patients undergoing ICD (2.8%) exchange (p = 0.002). LVEF ≤ 30%, New York Heart Association class ≥ 3, estimated glomerular filtration rate ≤ 30 mL/min/m(2) and haemoglobin ≤ 7 mmol/L were independently associated with mortality within 1 year after pulse generator replacement. There is a growing need for prospectively validated risk scores to weight individualized risk of mortality with the expected ICD therapy benefit and to support a well-informed, shared decision-making process. MDPI 2023-08-30 /pmc/articles/PMC10489035/ /pubmed/37685719 http://dx.doi.org/10.3390/jcm12175654 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Feijen, Michelle
Egorova, Anastasia D.
Kuijken, Teresa
Bootsma, Marianne
Schalij, Martin J.
van Erven, Lieselot
One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk
title One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk
title_full One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk
title_fullStr One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk
title_full_unstemmed One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk
title_short One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk
title_sort one-year mortality in patients undergoing an implantable cardioverter defibrillator or cardiac resynchronization therapy pulse generator replacement: identifying patients at risk
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10489035/
https://www.ncbi.nlm.nih.gov/pubmed/37685719
http://dx.doi.org/10.3390/jcm12175654
work_keys_str_mv AT feijenmichelle oneyearmortalityinpatientsundergoinganimplantablecardioverterdefibrillatororcardiacresynchronizationtherapypulsegeneratorreplacementidentifyingpatientsatrisk
AT egorovaanastasiad oneyearmortalityinpatientsundergoinganimplantablecardioverterdefibrillatororcardiacresynchronizationtherapypulsegeneratorreplacementidentifyingpatientsatrisk
AT kuijkenteresa oneyearmortalityinpatientsundergoinganimplantablecardioverterdefibrillatororcardiacresynchronizationtherapypulsegeneratorreplacementidentifyingpatientsatrisk
AT bootsmamarianne oneyearmortalityinpatientsundergoinganimplantablecardioverterdefibrillatororcardiacresynchronizationtherapypulsegeneratorreplacementidentifyingpatientsatrisk
AT schalijmartinj oneyearmortalityinpatientsundergoinganimplantablecardioverterdefibrillatororcardiacresynchronizationtherapypulsegeneratorreplacementidentifyingpatientsatrisk
AT vanervenlieselot oneyearmortalityinpatientsundergoinganimplantablecardioverterdefibrillatororcardiacresynchronizationtherapypulsegeneratorreplacementidentifyingpatientsatrisk