Cargando…
Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration
Clinical magnetic resonance imaging (MRI) aims for the highest possible image quality, while balancing the need for acceptable examination time, reasonable signal-to-noise ratio (SNR), and lowest artifact burden. With a recently introduced imaging acceleration technique, compressed sensing, the acqu...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10489124/ https://www.ncbi.nlm.nih.gov/pubmed/37685799 http://dx.doi.org/10.3390/jcm12175732 |
_version_ | 1785103631439101952 |
---|---|
author | Meister, Rieke Lisa Groth, Michael Zhang, Shuo Buhk, Jan-Hendrik Herrmann, Jochen |
author_facet | Meister, Rieke Lisa Groth, Michael Zhang, Shuo Buhk, Jan-Hendrik Herrmann, Jochen |
author_sort | Meister, Rieke Lisa |
collection | PubMed |
description | Clinical magnetic resonance imaging (MRI) aims for the highest possible image quality, while balancing the need for acceptable examination time, reasonable signal-to-noise ratio (SNR), and lowest artifact burden. With a recently introduced imaging acceleration technique, compressed sensing, the acquisition speed and image quality of pediatric brain tumor exams can be improved. However, little attention has been paid to its impact on method-related artifacts in pediatric brain MRI. This study assessed the overall artifact burden and artifact appearances in a standardized pediatric brain tumor MRI by comparing conventional parallel imaging acceleration with compressed sensing. This showed that compressed sensing resulted in fewer physiological artifacts in the FLAIR sequence, and a reduction in technical artifacts in the 3D T1 TFE sequences. Only a slight difference was noted in the T2 TSE sequence. A relatively new range of artifacts, which are likely technique-related, was noted in the 3D T1 TFE sequences. In conclusion, by equipping a basic pediatric brain tumor protocol for 3T MRI with compressed sensing, the overall burden of common artifacts can be reduced. However, attention should be paid to novel compressed-sensing-specific artifacts. |
format | Online Article Text |
id | pubmed-10489124 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-104891242023-09-09 Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration Meister, Rieke Lisa Groth, Michael Zhang, Shuo Buhk, Jan-Hendrik Herrmann, Jochen J Clin Med Article Clinical magnetic resonance imaging (MRI) aims for the highest possible image quality, while balancing the need for acceptable examination time, reasonable signal-to-noise ratio (SNR), and lowest artifact burden. With a recently introduced imaging acceleration technique, compressed sensing, the acquisition speed and image quality of pediatric brain tumor exams can be improved. However, little attention has been paid to its impact on method-related artifacts in pediatric brain MRI. This study assessed the overall artifact burden and artifact appearances in a standardized pediatric brain tumor MRI by comparing conventional parallel imaging acceleration with compressed sensing. This showed that compressed sensing resulted in fewer physiological artifacts in the FLAIR sequence, and a reduction in technical artifacts in the 3D T1 TFE sequences. Only a slight difference was noted in the T2 TSE sequence. A relatively new range of artifacts, which are likely technique-related, was noted in the 3D T1 TFE sequences. In conclusion, by equipping a basic pediatric brain tumor protocol for 3T MRI with compressed sensing, the overall burden of common artifacts can be reduced. However, attention should be paid to novel compressed-sensing-specific artifacts. MDPI 2023-09-03 /pmc/articles/PMC10489124/ /pubmed/37685799 http://dx.doi.org/10.3390/jcm12175732 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Meister, Rieke Lisa Groth, Michael Zhang, Shuo Buhk, Jan-Hendrik Herrmann, Jochen Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration |
title | Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration |
title_full | Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration |
title_fullStr | Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration |
title_full_unstemmed | Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration |
title_short | Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration |
title_sort | evaluation of artifact appearance and burden in pediatric brain tumor mr imaging with compressed sensing in comparison to conventional parallel imaging acceleration |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10489124/ https://www.ncbi.nlm.nih.gov/pubmed/37685799 http://dx.doi.org/10.3390/jcm12175732 |
work_keys_str_mv | AT meisterriekelisa evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration AT grothmichael evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration AT zhangshuo evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration AT buhkjanhendrik evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration AT herrmannjochen evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration |