Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration

Clinical magnetic resonance imaging (MRI) aims for the highest possible image quality, while balancing the need for acceptable examination time, reasonable signal-to-noise ratio (SNR), and lowest artifact burden. With a recently introduced imaging acceleration technique, compressed sensing, the acqu...

Descripción completa

Detalles Bibliográficos
Autores principales: Meister, Rieke Lisa, Groth, Michael, Zhang, Shuo, Buhk, Jan-Hendrik, Herrmann, Jochen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10489124/
https://www.ncbi.nlm.nih.gov/pubmed/37685799
http://dx.doi.org/10.3390/jcm12175732
_version_ 1785103631439101952
author Meister, Rieke Lisa
Groth, Michael
Zhang, Shuo
Buhk, Jan-Hendrik
Herrmann, Jochen
author_facet Meister, Rieke Lisa
Groth, Michael
Zhang, Shuo
Buhk, Jan-Hendrik
Herrmann, Jochen
author_sort Meister, Rieke Lisa
collection PubMed
description Clinical magnetic resonance imaging (MRI) aims for the highest possible image quality, while balancing the need for acceptable examination time, reasonable signal-to-noise ratio (SNR), and lowest artifact burden. With a recently introduced imaging acceleration technique, compressed sensing, the acquisition speed and image quality of pediatric brain tumor exams can be improved. However, little attention has been paid to its impact on method-related artifacts in pediatric brain MRI. This study assessed the overall artifact burden and artifact appearances in a standardized pediatric brain tumor MRI by comparing conventional parallel imaging acceleration with compressed sensing. This showed that compressed sensing resulted in fewer physiological artifacts in the FLAIR sequence, and a reduction in technical artifacts in the 3D T1 TFE sequences. Only a slight difference was noted in the T2 TSE sequence. A relatively new range of artifacts, which are likely technique-related, was noted in the 3D T1 TFE sequences. In conclusion, by equipping a basic pediatric brain tumor protocol for 3T MRI with compressed sensing, the overall burden of common artifacts can be reduced. However, attention should be paid to novel compressed-sensing-specific artifacts.
format Online
Article
Text
id pubmed-10489124
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104891242023-09-09 Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration Meister, Rieke Lisa Groth, Michael Zhang, Shuo Buhk, Jan-Hendrik Herrmann, Jochen J Clin Med Article Clinical magnetic resonance imaging (MRI) aims for the highest possible image quality, while balancing the need for acceptable examination time, reasonable signal-to-noise ratio (SNR), and lowest artifact burden. With a recently introduced imaging acceleration technique, compressed sensing, the acquisition speed and image quality of pediatric brain tumor exams can be improved. However, little attention has been paid to its impact on method-related artifacts in pediatric brain MRI. This study assessed the overall artifact burden and artifact appearances in a standardized pediatric brain tumor MRI by comparing conventional parallel imaging acceleration with compressed sensing. This showed that compressed sensing resulted in fewer physiological artifacts in the FLAIR sequence, and a reduction in technical artifacts in the 3D T1 TFE sequences. Only a slight difference was noted in the T2 TSE sequence. A relatively new range of artifacts, which are likely technique-related, was noted in the 3D T1 TFE sequences. In conclusion, by equipping a basic pediatric brain tumor protocol for 3T MRI with compressed sensing, the overall burden of common artifacts can be reduced. However, attention should be paid to novel compressed-sensing-specific artifacts. MDPI 2023-09-03 /pmc/articles/PMC10489124/ /pubmed/37685799 http://dx.doi.org/10.3390/jcm12175732 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Meister, Rieke Lisa
Groth, Michael
Zhang, Shuo
Buhk, Jan-Hendrik
Herrmann, Jochen
Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration
title Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration
title_full Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration
title_fullStr Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration
title_full_unstemmed Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration
title_short Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration
title_sort evaluation of artifact appearance and burden in pediatric brain tumor mr imaging with compressed sensing in comparison to conventional parallel imaging acceleration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10489124/
https://www.ncbi.nlm.nih.gov/pubmed/37685799
http://dx.doi.org/10.3390/jcm12175732
work_keys_str_mv AT meisterriekelisa evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration
AT grothmichael evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration
AT zhangshuo evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration
AT buhkjanhendrik evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration
AT herrmannjochen evaluationofartifactappearanceandburdeninpediatricbraintumormrimagingwithcompressedsensingincomparisontoconventionalparallelimagingacceleration