Cargando…

Development of Fiber-Bragg-Grating-Integrated Artificial Embedded Tendon for Multifunctional Assessment of Temperature, Strain, and Curvature

This paper presents the development and application of an optical fiber-embedded tendon based on biomimetic multifunctional structures. The tendon was fabricated using a thermocure resin (polyurethane) and the three optical fibers with one fiber Bragg grating (FBG) inscribed in each fiber. The first...

Descripción completa

Detalles Bibliográficos
Autores principales: Pires-Junior, Robertson, Frizera, Anselmo, Marques, Carlos, Leal-Junior, Arnaldo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490486/
https://www.ncbi.nlm.nih.gov/pubmed/37687788
http://dx.doi.org/10.3390/s23177332
_version_ 1785103851223777280
author Pires-Junior, Robertson
Frizera, Anselmo
Marques, Carlos
Leal-Junior, Arnaldo
author_facet Pires-Junior, Robertson
Frizera, Anselmo
Marques, Carlos
Leal-Junior, Arnaldo
author_sort Pires-Junior, Robertson
collection PubMed
description This paper presents the development and application of an optical fiber-embedded tendon based on biomimetic multifunctional structures. The tendon was fabricated using a thermocure resin (polyurethane) and the three optical fibers with one fiber Bragg grating (FBG) inscribed in each fiber. The first step in the FBG-integrated artificial tendon analysis is the mechanical properties assessment through stress–strain curves, which indicated the customization of the proposed device, since it is possible to tailor the Young’s modulus and strain limit of the tendon as a function of the integrated optical fibers, where the coated and uncoated fibers lead to differences in both parameters, i.e., strain limits and Young’s modulus. Then, the artificial tendon integrated with FBG sensors undergoes three types of characterization, which assesses the influence of temperature, single-axis strain, and curvature. Results show similarities in the temperature responses in all analyzed FBGs, where the variations are related to the heterogeneity on the polyurethane matrix distribution. In contrast, the FBGs embedded in the tendon presented a reduction in the strain sensitivity when compared with the bare FBGs (i.e., without the integration in the artificial tendon). Such results demonstrated a reduction in the sensitivity as high as 77% when compared with the bare FBGs, which is related to strain field distributions in the FBGs when embedded in the tendon. In addition, the curvature tests indicated variations in both optical power and wavelength shift, where both parameters are used on the angle estimation using the proposed multifunctional artificial tendon. To that extent, root mean squared error of around 3.25° is obtained when both spectral features are considered. Therefore, the proposed approach indicates a suitable method for the development of smart structures in which the multifunctional capability of the device leads to the possibility of using not only as a structural element in tendon-driven actuators and devices, but also as a sensor element for the different structures.
format Online
Article
Text
id pubmed-10490486
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104904862023-09-09 Development of Fiber-Bragg-Grating-Integrated Artificial Embedded Tendon for Multifunctional Assessment of Temperature, Strain, and Curvature Pires-Junior, Robertson Frizera, Anselmo Marques, Carlos Leal-Junior, Arnaldo Sensors (Basel) Article This paper presents the development and application of an optical fiber-embedded tendon based on biomimetic multifunctional structures. The tendon was fabricated using a thermocure resin (polyurethane) and the three optical fibers with one fiber Bragg grating (FBG) inscribed in each fiber. The first step in the FBG-integrated artificial tendon analysis is the mechanical properties assessment through stress–strain curves, which indicated the customization of the proposed device, since it is possible to tailor the Young’s modulus and strain limit of the tendon as a function of the integrated optical fibers, where the coated and uncoated fibers lead to differences in both parameters, i.e., strain limits and Young’s modulus. Then, the artificial tendon integrated with FBG sensors undergoes three types of characterization, which assesses the influence of temperature, single-axis strain, and curvature. Results show similarities in the temperature responses in all analyzed FBGs, where the variations are related to the heterogeneity on the polyurethane matrix distribution. In contrast, the FBGs embedded in the tendon presented a reduction in the strain sensitivity when compared with the bare FBGs (i.e., without the integration in the artificial tendon). Such results demonstrated a reduction in the sensitivity as high as 77% when compared with the bare FBGs, which is related to strain field distributions in the FBGs when embedded in the tendon. In addition, the curvature tests indicated variations in both optical power and wavelength shift, where both parameters are used on the angle estimation using the proposed multifunctional artificial tendon. To that extent, root mean squared error of around 3.25° is obtained when both spectral features are considered. Therefore, the proposed approach indicates a suitable method for the development of smart structures in which the multifunctional capability of the device leads to the possibility of using not only as a structural element in tendon-driven actuators and devices, but also as a sensor element for the different structures. MDPI 2023-08-22 /pmc/articles/PMC10490486/ /pubmed/37687788 http://dx.doi.org/10.3390/s23177332 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pires-Junior, Robertson
Frizera, Anselmo
Marques, Carlos
Leal-Junior, Arnaldo
Development of Fiber-Bragg-Grating-Integrated Artificial Embedded Tendon for Multifunctional Assessment of Temperature, Strain, and Curvature
title Development of Fiber-Bragg-Grating-Integrated Artificial Embedded Tendon for Multifunctional Assessment of Temperature, Strain, and Curvature
title_full Development of Fiber-Bragg-Grating-Integrated Artificial Embedded Tendon for Multifunctional Assessment of Temperature, Strain, and Curvature
title_fullStr Development of Fiber-Bragg-Grating-Integrated Artificial Embedded Tendon for Multifunctional Assessment of Temperature, Strain, and Curvature
title_full_unstemmed Development of Fiber-Bragg-Grating-Integrated Artificial Embedded Tendon for Multifunctional Assessment of Temperature, Strain, and Curvature
title_short Development of Fiber-Bragg-Grating-Integrated Artificial Embedded Tendon for Multifunctional Assessment of Temperature, Strain, and Curvature
title_sort development of fiber-bragg-grating-integrated artificial embedded tendon for multifunctional assessment of temperature, strain, and curvature
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490486/
https://www.ncbi.nlm.nih.gov/pubmed/37687788
http://dx.doi.org/10.3390/s23177332
work_keys_str_mv AT piresjuniorrobertson developmentoffiberbragggratingintegratedartificialembeddedtendonformultifunctionalassessmentoftemperaturestrainandcurvature
AT frizeraanselmo developmentoffiberbragggratingintegratedartificialembeddedtendonformultifunctionalassessmentoftemperaturestrainandcurvature
AT marquescarlos developmentoffiberbragggratingintegratedartificialembeddedtendonformultifunctionalassessmentoftemperaturestrainandcurvature
AT lealjuniorarnaldo developmentoffiberbragggratingintegratedartificialembeddedtendonformultifunctionalassessmentoftemperaturestrainandcurvature