Cargando…
Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items
As part of establishing a management system to prevent the illegal transfer of nuclear items, automatic nuclear item detection technology is required during customs clearance. However, it is challenging to acquire X-ray images of major nuclear items (e.g., nuclear fuel and gas centrifuges) loaded in...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490638/ https://www.ncbi.nlm.nih.gov/pubmed/37687993 http://dx.doi.org/10.3390/s23177537 |
_version_ | 1785103886471659520 |
---|---|
author | Jang, Haneol Lee, Chansuh Ko, Hansol Lim, KyungTae |
author_facet | Jang, Haneol Lee, Chansuh Ko, Hansol Lim, KyungTae |
author_sort | Jang, Haneol |
collection | PubMed |
description | As part of establishing a management system to prevent the illegal transfer of nuclear items, automatic nuclear item detection technology is required during customs clearance. However, it is challenging to acquire X-ray images of major nuclear items (e.g., nuclear fuel and gas centrifuges) loaded in cargo with which to train a cargo inspection model. In this work, we propose a new means of data augmentation to alleviate the lack of X-ray training data. The proposed augmentation method generates synthetic X-ray images for the training of semantic segmentation models combining the X-ray images of nuclear items and X-ray cargo background images. To evaluate the effectiveness of the proposed data augmentation technique, we trained representative semantic segmentation models and performed extensive experiments to assess its quantitative and qualitative performance capabilities. Our findings show that multiple item insertions to respond to actual X-ray cargo inspection situations and the resulting occlusion expressions significantly affect the performance of the segmentation models. We believe that this augmentation research will enhance automatic cargo inspections to prevent the illegal transfer of nuclear items at airports and ports. |
format | Online Article Text |
id | pubmed-10490638 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-104906382023-09-09 Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items Jang, Haneol Lee, Chansuh Ko, Hansol Lim, KyungTae Sensors (Basel) Article As part of establishing a management system to prevent the illegal transfer of nuclear items, automatic nuclear item detection technology is required during customs clearance. However, it is challenging to acquire X-ray images of major nuclear items (e.g., nuclear fuel and gas centrifuges) loaded in cargo with which to train a cargo inspection model. In this work, we propose a new means of data augmentation to alleviate the lack of X-ray training data. The proposed augmentation method generates synthetic X-ray images for the training of semantic segmentation models combining the X-ray images of nuclear items and X-ray cargo background images. To evaluate the effectiveness of the proposed data augmentation technique, we trained representative semantic segmentation models and performed extensive experiments to assess its quantitative and qualitative performance capabilities. Our findings show that multiple item insertions to respond to actual X-ray cargo inspection situations and the resulting occlusion expressions significantly affect the performance of the segmentation models. We believe that this augmentation research will enhance automatic cargo inspections to prevent the illegal transfer of nuclear items at airports and ports. MDPI 2023-08-30 /pmc/articles/PMC10490638/ /pubmed/37687993 http://dx.doi.org/10.3390/s23177537 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jang, Haneol Lee, Chansuh Ko, Hansol Lim, KyungTae Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items |
title | Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items |
title_full | Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items |
title_fullStr | Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items |
title_full_unstemmed | Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items |
title_short | Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items |
title_sort | data augmentation of x-ray images for automatic cargo inspection of nuclear items |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490638/ https://www.ncbi.nlm.nih.gov/pubmed/37687993 http://dx.doi.org/10.3390/s23177537 |
work_keys_str_mv | AT janghaneol dataaugmentationofxrayimagesforautomaticcargoinspectionofnuclearitems AT leechansuh dataaugmentationofxrayimagesforautomaticcargoinspectionofnuclearitems AT kohansol dataaugmentationofxrayimagesforautomaticcargoinspectionofnuclearitems AT limkyungtae dataaugmentationofxrayimagesforautomaticcargoinspectionofnuclearitems |