Cargando…

Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items

As part of establishing a management system to prevent the illegal transfer of nuclear items, automatic nuclear item detection technology is required during customs clearance. However, it is challenging to acquire X-ray images of major nuclear items (e.g., nuclear fuel and gas centrifuges) loaded in...

Descripción completa

Detalles Bibliográficos
Autores principales: Jang, Haneol, Lee, Chansuh, Ko, Hansol, Lim, KyungTae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490638/
https://www.ncbi.nlm.nih.gov/pubmed/37687993
http://dx.doi.org/10.3390/s23177537
_version_ 1785103886471659520
author Jang, Haneol
Lee, Chansuh
Ko, Hansol
Lim, KyungTae
author_facet Jang, Haneol
Lee, Chansuh
Ko, Hansol
Lim, KyungTae
author_sort Jang, Haneol
collection PubMed
description As part of establishing a management system to prevent the illegal transfer of nuclear items, automatic nuclear item detection technology is required during customs clearance. However, it is challenging to acquire X-ray images of major nuclear items (e.g., nuclear fuel and gas centrifuges) loaded in cargo with which to train a cargo inspection model. In this work, we propose a new means of data augmentation to alleviate the lack of X-ray training data. The proposed augmentation method generates synthetic X-ray images for the training of semantic segmentation models combining the X-ray images of nuclear items and X-ray cargo background images. To evaluate the effectiveness of the proposed data augmentation technique, we trained representative semantic segmentation models and performed extensive experiments to assess its quantitative and qualitative performance capabilities. Our findings show that multiple item insertions to respond to actual X-ray cargo inspection situations and the resulting occlusion expressions significantly affect the performance of the segmentation models. We believe that this augmentation research will enhance automatic cargo inspections to prevent the illegal transfer of nuclear items at airports and ports.
format Online
Article
Text
id pubmed-10490638
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104906382023-09-09 Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items Jang, Haneol Lee, Chansuh Ko, Hansol Lim, KyungTae Sensors (Basel) Article As part of establishing a management system to prevent the illegal transfer of nuclear items, automatic nuclear item detection technology is required during customs clearance. However, it is challenging to acquire X-ray images of major nuclear items (e.g., nuclear fuel and gas centrifuges) loaded in cargo with which to train a cargo inspection model. In this work, we propose a new means of data augmentation to alleviate the lack of X-ray training data. The proposed augmentation method generates synthetic X-ray images for the training of semantic segmentation models combining the X-ray images of nuclear items and X-ray cargo background images. To evaluate the effectiveness of the proposed data augmentation technique, we trained representative semantic segmentation models and performed extensive experiments to assess its quantitative and qualitative performance capabilities. Our findings show that multiple item insertions to respond to actual X-ray cargo inspection situations and the resulting occlusion expressions significantly affect the performance of the segmentation models. We believe that this augmentation research will enhance automatic cargo inspections to prevent the illegal transfer of nuclear items at airports and ports. MDPI 2023-08-30 /pmc/articles/PMC10490638/ /pubmed/37687993 http://dx.doi.org/10.3390/s23177537 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jang, Haneol
Lee, Chansuh
Ko, Hansol
Lim, KyungTae
Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items
title Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items
title_full Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items
title_fullStr Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items
title_full_unstemmed Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items
title_short Data Augmentation of X-ray Images for Automatic Cargo Inspection of Nuclear Items
title_sort data augmentation of x-ray images for automatic cargo inspection of nuclear items
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490638/
https://www.ncbi.nlm.nih.gov/pubmed/37687993
http://dx.doi.org/10.3390/s23177537
work_keys_str_mv AT janghaneol dataaugmentationofxrayimagesforautomaticcargoinspectionofnuclearitems
AT leechansuh dataaugmentationofxrayimagesforautomaticcargoinspectionofnuclearitems
AT kohansol dataaugmentationofxrayimagesforautomaticcargoinspectionofnuclearitems
AT limkyungtae dataaugmentationofxrayimagesforautomaticcargoinspectionofnuclearitems