Investigation on the Effective Measures for Improving the Performance of Calorimetric Microflow Sensor
The performance of the calorimetric microflow sensor is closely related to the thermal sensing part design, including structure parameter, heater temperature, and operation environment. In this paper, several measures to enhance the performance of the calorimetric microflow sensor were proposed and...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490643/ https://www.ncbi.nlm.nih.gov/pubmed/37687873 http://dx.doi.org/10.3390/s23177413 |
_version_ | 1785103887626141696 |
---|---|
author | Qi, Jiali Shao, Chun Wu, Wei Wang, Ruijin |
author_facet | Qi, Jiali Shao, Chun Wu, Wei Wang, Ruijin |
author_sort | Qi, Jiali |
collection | PubMed |
description | The performance of the calorimetric microflow sensor is closely related to the thermal sensing part design, including structure parameter, heater temperature, and operation environment. In this paper, several measures to enhance the performance of the calorimetric microflow sensor were proposed and further verified by numerical simulations. The results demonstrate that it is more favorable to reduce the negative impact of flow separation as the space between detectors and heater is set to be 1.6 μm so as to improve the accuracy of the sensor. With an appropriate gap, the front arranged obstacle of the upstream detector can effectively widen the measure range of the sensor, benefiting from the decrease in upstream viscous dissipation. Compared to a cantilever structure, the resonances can be effectively suppressed when the heater and detectors are designed as bridge structures. In particular, the maximum amplitude of the bridge structure is only 0.022 μm at 70 sccm, which is 53% lower than that of the cantilever structure. The optimized sensor widens the range by 14.3% and significantly increases the sensitivity at high flow rates. Moreover, the feasibility of the improved measures is also illustrated via the consistency of the trend between the simulation results and experimental ones. |
format | Online Article Text |
id | pubmed-10490643 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-104906432023-09-09 Investigation on the Effective Measures for Improving the Performance of Calorimetric Microflow Sensor Qi, Jiali Shao, Chun Wu, Wei Wang, Ruijin Sensors (Basel) Article The performance of the calorimetric microflow sensor is closely related to the thermal sensing part design, including structure parameter, heater temperature, and operation environment. In this paper, several measures to enhance the performance of the calorimetric microflow sensor were proposed and further verified by numerical simulations. The results demonstrate that it is more favorable to reduce the negative impact of flow separation as the space between detectors and heater is set to be 1.6 μm so as to improve the accuracy of the sensor. With an appropriate gap, the front arranged obstacle of the upstream detector can effectively widen the measure range of the sensor, benefiting from the decrease in upstream viscous dissipation. Compared to a cantilever structure, the resonances can be effectively suppressed when the heater and detectors are designed as bridge structures. In particular, the maximum amplitude of the bridge structure is only 0.022 μm at 70 sccm, which is 53% lower than that of the cantilever structure. The optimized sensor widens the range by 14.3% and significantly increases the sensitivity at high flow rates. Moreover, the feasibility of the improved measures is also illustrated via the consistency of the trend between the simulation results and experimental ones. MDPI 2023-08-25 /pmc/articles/PMC10490643/ /pubmed/37687873 http://dx.doi.org/10.3390/s23177413 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Qi, Jiali Shao, Chun Wu, Wei Wang, Ruijin Investigation on the Effective Measures for Improving the Performance of Calorimetric Microflow Sensor |
title | Investigation on the Effective Measures for Improving the Performance of Calorimetric Microflow Sensor |
title_full | Investigation on the Effective Measures for Improving the Performance of Calorimetric Microflow Sensor |
title_fullStr | Investigation on the Effective Measures for Improving the Performance of Calorimetric Microflow Sensor |
title_full_unstemmed | Investigation on the Effective Measures for Improving the Performance of Calorimetric Microflow Sensor |
title_short | Investigation on the Effective Measures for Improving the Performance of Calorimetric Microflow Sensor |
title_sort | investigation on the effective measures for improving the performance of calorimetric microflow sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490643/ https://www.ncbi.nlm.nih.gov/pubmed/37687873 http://dx.doi.org/10.3390/s23177413 |
work_keys_str_mv | AT qijiali investigationontheeffectivemeasuresforimprovingtheperformanceofcalorimetricmicroflowsensor AT shaochun investigationontheeffectivemeasuresforimprovingtheperformanceofcalorimetricmicroflowsensor AT wuwei investigationontheeffectivemeasuresforimprovingtheperformanceofcalorimetricmicroflowsensor AT wangruijin investigationontheeffectivemeasuresforimprovingtheperformanceofcalorimetricmicroflowsensor |