Design and Implementation of an Atrial Fibrillation Detection Algorithm on the ARM Cortex-M4 Microcontroller

At present, a medium-level microcontroller is capable of performing edge computing and can handle the computation of neural network kernel functions. This makes it possible to implement a complete end-to-end solution incorporating signal acquisition, digital signal processing, and machine learning f...

Descripción completa

Detalles Bibliográficos
Autores principales: Żyliński, Marek, Nassibi, Amir, Mandic, Danilo P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490693/
https://www.ncbi.nlm.nih.gov/pubmed/37687975
http://dx.doi.org/10.3390/s23177521
_version_ 1785103899448836096
author Żyliński, Marek
Nassibi, Amir
Mandic, Danilo P.
author_facet Żyliński, Marek
Nassibi, Amir
Mandic, Danilo P.
author_sort Żyliński, Marek
collection PubMed
description At present, a medium-level microcontroller is capable of performing edge computing and can handle the computation of neural network kernel functions. This makes it possible to implement a complete end-to-end solution incorporating signal acquisition, digital signal processing, and machine learning for the classification of cardiac arrhythmias on a small wearable device. In this work, we describe the design and implementation of several classifiers for atrial fibrillation detection on a general-purpose ARM Cortex-M4 microcontroller. We used the CMSIS-DSP library, which supports Naïve Bayes and Support Vector Machine classifiers, with different kernel functions. We also developed Python scripts to automatically transfer the Python model (trained in Scikit-learn) to the C environment. To train and evaluate the models, we used part of the data from the PhysioNet/Computing in Cardiology Challenge 2020 and performed simple classification of atrial fibrillation based on heart-rate irregularity. The performance of the classifiers was tested on a general-purpose ARM Cortex-M4 microcontroller (STM32WB55RG). Our study reveals that among the tested classifiers, the SVM classifier with RBF kernel function achieves the highest accuracy of 96.9%, sensitivity of 98.4%, and specificity of 95.8%. The execution time of this classifier was 720 [Formula: see text] s per recording. We also discuss the advantages of moving computing tasks to edge devices, including increased power efficiency of the system, improved patient data privacy and security, and reduced overall system operation costs. In addition, we highlight a problem with false-positive detection and unclear significance of device-detected atrial fibrillation.
format Online
Article
Text
id pubmed-10490693
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104906932023-09-09 Design and Implementation of an Atrial Fibrillation Detection Algorithm on the ARM Cortex-M4 Microcontroller Żyliński, Marek Nassibi, Amir Mandic, Danilo P. Sensors (Basel) Article At present, a medium-level microcontroller is capable of performing edge computing and can handle the computation of neural network kernel functions. This makes it possible to implement a complete end-to-end solution incorporating signal acquisition, digital signal processing, and machine learning for the classification of cardiac arrhythmias on a small wearable device. In this work, we describe the design and implementation of several classifiers for atrial fibrillation detection on a general-purpose ARM Cortex-M4 microcontroller. We used the CMSIS-DSP library, which supports Naïve Bayes and Support Vector Machine classifiers, with different kernel functions. We also developed Python scripts to automatically transfer the Python model (trained in Scikit-learn) to the C environment. To train and evaluate the models, we used part of the data from the PhysioNet/Computing in Cardiology Challenge 2020 and performed simple classification of atrial fibrillation based on heart-rate irregularity. The performance of the classifiers was tested on a general-purpose ARM Cortex-M4 microcontroller (STM32WB55RG). Our study reveals that among the tested classifiers, the SVM classifier with RBF kernel function achieves the highest accuracy of 96.9%, sensitivity of 98.4%, and specificity of 95.8%. The execution time of this classifier was 720 [Formula: see text] s per recording. We also discuss the advantages of moving computing tasks to edge devices, including increased power efficiency of the system, improved patient data privacy and security, and reduced overall system operation costs. In addition, we highlight a problem with false-positive detection and unclear significance of device-detected atrial fibrillation. MDPI 2023-08-30 /pmc/articles/PMC10490693/ /pubmed/37687975 http://dx.doi.org/10.3390/s23177521 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Żyliński, Marek
Nassibi, Amir
Mandic, Danilo P.
Design and Implementation of an Atrial Fibrillation Detection Algorithm on the ARM Cortex-M4 Microcontroller
title Design and Implementation of an Atrial Fibrillation Detection Algorithm on the ARM Cortex-M4 Microcontroller
title_full Design and Implementation of an Atrial Fibrillation Detection Algorithm on the ARM Cortex-M4 Microcontroller
title_fullStr Design and Implementation of an Atrial Fibrillation Detection Algorithm on the ARM Cortex-M4 Microcontroller
title_full_unstemmed Design and Implementation of an Atrial Fibrillation Detection Algorithm on the ARM Cortex-M4 Microcontroller
title_short Design and Implementation of an Atrial Fibrillation Detection Algorithm on the ARM Cortex-M4 Microcontroller
title_sort design and implementation of an atrial fibrillation detection algorithm on the arm cortex-m4 microcontroller
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490693/
https://www.ncbi.nlm.nih.gov/pubmed/37687975
http://dx.doi.org/10.3390/s23177521
work_keys_str_mv AT zylinskimarek designandimplementationofanatrialfibrillationdetectionalgorithmonthearmcortexm4microcontroller
AT nassibiamir designandimplementationofanatrialfibrillationdetectionalgorithmonthearmcortexm4microcontroller
AT mandicdanilop designandimplementationofanatrialfibrillationdetectionalgorithmonthearmcortexm4microcontroller