Cargando…

Design Method of Three-Component Optic Fiber Balance Based on Fabry–Perot Displacement Sensor

This article proposes a new type of three-component optic fiber balance based on Fabry–Perot displacement measurement technology based on the structure of the pulse wind tunnel balance. This paper systematically introduces the force measurement principle and design process of a three-component optic...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Bin, Yu, Shien, Zhang, Jianzhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490722/
https://www.ncbi.nlm.nih.gov/pubmed/37687948
http://dx.doi.org/10.3390/s23177492
_version_ 1785103906390409216
author Xu, Bin
Yu, Shien
Zhang, Jianzhong
author_facet Xu, Bin
Yu, Shien
Zhang, Jianzhong
author_sort Xu, Bin
collection PubMed
description This article proposes a new type of three-component optic fiber balance based on Fabry–Perot displacement measurement technology based on the structure of the pulse wind tunnel balance. This paper systematically introduces the force measurement principle and design process of a three-component optic fiber balance and conducts relevant simulation analysis and experimental verification. The simulation results show that the Fabry–Perot sensor can achieve significant sensitivity to cavity length changes, and when used in existing balance structures, sensitivity gains can be achieved by changing the probe height without the need to modify the original structure of the balance. Finally, the feasibility of the design method was verified through calibration experiments: the optic fiber balance has high sensitivity and good linearity compared to simulation sensitivity, the error is less than 6%, and the calibration accuracy of each component is better than 0.13%, which is better than the existing traditional strain balance (0.37%). The pulse wind tunnel force measurement test has a short test time and a large model mass, and the balance needs to have a large stiffness to meet the short-term force measurement requirements. The introduction of more sensitive optic fiber balance force measurement technology is expected to solve the contradiction between the stiffness and sensitivity of force measurement systems.
format Online
Article
Text
id pubmed-10490722
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104907222023-09-09 Design Method of Three-Component Optic Fiber Balance Based on Fabry–Perot Displacement Sensor Xu, Bin Yu, Shien Zhang, Jianzhong Sensors (Basel) Article This article proposes a new type of three-component optic fiber balance based on Fabry–Perot displacement measurement technology based on the structure of the pulse wind tunnel balance. This paper systematically introduces the force measurement principle and design process of a three-component optic fiber balance and conducts relevant simulation analysis and experimental verification. The simulation results show that the Fabry–Perot sensor can achieve significant sensitivity to cavity length changes, and when used in existing balance structures, sensitivity gains can be achieved by changing the probe height without the need to modify the original structure of the balance. Finally, the feasibility of the design method was verified through calibration experiments: the optic fiber balance has high sensitivity and good linearity compared to simulation sensitivity, the error is less than 6%, and the calibration accuracy of each component is better than 0.13%, which is better than the existing traditional strain balance (0.37%). The pulse wind tunnel force measurement test has a short test time and a large model mass, and the balance needs to have a large stiffness to meet the short-term force measurement requirements. The introduction of more sensitive optic fiber balance force measurement technology is expected to solve the contradiction between the stiffness and sensitivity of force measurement systems. MDPI 2023-08-29 /pmc/articles/PMC10490722/ /pubmed/37687948 http://dx.doi.org/10.3390/s23177492 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xu, Bin
Yu, Shien
Zhang, Jianzhong
Design Method of Three-Component Optic Fiber Balance Based on Fabry–Perot Displacement Sensor
title Design Method of Three-Component Optic Fiber Balance Based on Fabry–Perot Displacement Sensor
title_full Design Method of Three-Component Optic Fiber Balance Based on Fabry–Perot Displacement Sensor
title_fullStr Design Method of Three-Component Optic Fiber Balance Based on Fabry–Perot Displacement Sensor
title_full_unstemmed Design Method of Three-Component Optic Fiber Balance Based on Fabry–Perot Displacement Sensor
title_short Design Method of Three-Component Optic Fiber Balance Based on Fabry–Perot Displacement Sensor
title_sort design method of three-component optic fiber balance based on fabry–perot displacement sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10490722/
https://www.ncbi.nlm.nih.gov/pubmed/37687948
http://dx.doi.org/10.3390/s23177492
work_keys_str_mv AT xubin designmethodofthreecomponentopticfiberbalancebasedonfabryperotdisplacementsensor
AT yushien designmethodofthreecomponentopticfiberbalancebasedonfabryperotdisplacementsensor
AT zhangjianzhong designmethodofthreecomponentopticfiberbalancebasedonfabryperotdisplacementsensor