Device-associated infections in neonatal care units in a middle-income country, 2016–2018

OBJECTIVE: Describe the device-associated infections in the NICUs in Cali – Colombia, a middle-income country, between August 2016 to December 2018. METHODS: Observational cross-sectional study evaluating reports of device-associated infections in 10 NICUs in Cali, Colombia, between August 2016 and...

Descripción completa

Detalles Bibliográficos
Autores principales: Torres-Muñoz, Javier, Hoyos, Ingrith Viviana, Murillo, Jennifer, Holguin, Jorge, Dávalos, Diana, López, Eduardo, Torres-Figueroa, Sofia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492145/
https://www.ncbi.nlm.nih.gov/pubmed/37148912
http://dx.doi.org/10.1016/j.jped.2023.03.004
_version_ 1785104188287483904
author Torres-Muñoz, Javier
Hoyos, Ingrith Viviana
Murillo, Jennifer
Holguin, Jorge
Dávalos, Diana
López, Eduardo
Torres-Figueroa, Sofia
author_facet Torres-Muñoz, Javier
Hoyos, Ingrith Viviana
Murillo, Jennifer
Holguin, Jorge
Dávalos, Diana
López, Eduardo
Torres-Figueroa, Sofia
author_sort Torres-Muñoz, Javier
collection PubMed
description OBJECTIVE: Describe the device-associated infections in the NICUs in Cali – Colombia, a middle-income country, between August 2016 to December 2018. METHODS: Observational cross-sectional study evaluating reports of device-associated infections in 10 NICUs in Cali, Colombia, between August 2016 and December 2018. Socio-demographic and microbiological data were obtained from the National Public Health surveillance system, through a specialized notification sheet. The relationship of device-associated infections with several outcomes including birth weight, microorganisms, and mortality was evaluated using OR CI95%, using the logistic regression model. Data processing was performed using the statistical program STATA 16. RESULTS: 226 device-associated infections were reported. The rate of infection with central line-associated bloodstream infections was 2.62 per 1000 days of device use and 2.32 per 1000 days for ventilator-associated pneumonia. This was higher in neonates under 1000 g; 4.59 and 4.10, respectively. 43.4% of the infections were due to gram-negative bacteria and 42.3% were due to gram-positive bacteria. Time from hospitalization to diagnosis of all device-associated infections had a median of 14 days. When compared by weight, infants with a weight lower than 1000 g had a greater chance of death (OR 3.61; 95% CI 1.53–8.49, p = 0.03). Infection by gram-negative bacteria was associated with a greater chance of dying (OR 3.06 CI 95 1.33–7.06, p = 0.008). CONCLUSIONS: These results highlight the need to maintain epidemiological surveillance processes in neonatal intensive care units, especially when medical devices are used.
format Online
Article
Text
id pubmed-10492145
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104921452023-09-10 Device-associated infections in neonatal care units in a middle-income country, 2016–2018 Torres-Muñoz, Javier Hoyos, Ingrith Viviana Murillo, Jennifer Holguin, Jorge Dávalos, Diana López, Eduardo Torres-Figueroa, Sofia J Pediatr (Rio J) Original Article OBJECTIVE: Describe the device-associated infections in the NICUs in Cali – Colombia, a middle-income country, between August 2016 to December 2018. METHODS: Observational cross-sectional study evaluating reports of device-associated infections in 10 NICUs in Cali, Colombia, between August 2016 and December 2018. Socio-demographic and microbiological data were obtained from the National Public Health surveillance system, through a specialized notification sheet. The relationship of device-associated infections with several outcomes including birth weight, microorganisms, and mortality was evaluated using OR CI95%, using the logistic regression model. Data processing was performed using the statistical program STATA 16. RESULTS: 226 device-associated infections were reported. The rate of infection with central line-associated bloodstream infections was 2.62 per 1000 days of device use and 2.32 per 1000 days for ventilator-associated pneumonia. This was higher in neonates under 1000 g; 4.59 and 4.10, respectively. 43.4% of the infections were due to gram-negative bacteria and 42.3% were due to gram-positive bacteria. Time from hospitalization to diagnosis of all device-associated infections had a median of 14 days. When compared by weight, infants with a weight lower than 1000 g had a greater chance of death (OR 3.61; 95% CI 1.53–8.49, p = 0.03). Infection by gram-negative bacteria was associated with a greater chance of dying (OR 3.06 CI 95 1.33–7.06, p = 0.008). CONCLUSIONS: These results highlight the need to maintain epidemiological surveillance processes in neonatal intensive care units, especially when medical devices are used. Elsevier 2023-05-03 /pmc/articles/PMC10492145/ /pubmed/37148912 http://dx.doi.org/10.1016/j.jped.2023.03.004 Text en © 2023 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Torres-Muñoz, Javier
Hoyos, Ingrith Viviana
Murillo, Jennifer
Holguin, Jorge
Dávalos, Diana
López, Eduardo
Torres-Figueroa, Sofia
Device-associated infections in neonatal care units in a middle-income country, 2016–2018
title Device-associated infections in neonatal care units in a middle-income country, 2016–2018
title_full Device-associated infections in neonatal care units in a middle-income country, 2016–2018
title_fullStr Device-associated infections in neonatal care units in a middle-income country, 2016–2018
title_full_unstemmed Device-associated infections in neonatal care units in a middle-income country, 2016–2018
title_short Device-associated infections in neonatal care units in a middle-income country, 2016–2018
title_sort device-associated infections in neonatal care units in a middle-income country, 2016–2018
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492145/
https://www.ncbi.nlm.nih.gov/pubmed/37148912
http://dx.doi.org/10.1016/j.jped.2023.03.004
work_keys_str_mv AT torresmunozjavier deviceassociatedinfectionsinneonatalcareunitsinamiddleincomecountry20162018
AT hoyosingrithviviana deviceassociatedinfectionsinneonatalcareunitsinamiddleincomecountry20162018
AT murillojennifer deviceassociatedinfectionsinneonatalcareunitsinamiddleincomecountry20162018
AT holguinjorge deviceassociatedinfectionsinneonatalcareunitsinamiddleincomecountry20162018
AT davalosdiana deviceassociatedinfectionsinneonatalcareunitsinamiddleincomecountry20162018
AT lopezeduardo deviceassociatedinfectionsinneonatalcareunitsinamiddleincomecountry20162018
AT torresfigueroasofia deviceassociatedinfectionsinneonatalcareunitsinamiddleincomecountry20162018