Cargando…
A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture
Tibial pilon fractures are difficult to treat. These fractures are associated with a high frequency of soft tissue complications. Therefore, two-stage surgery and less invasive surgical strategies using external fixation have been reported. The patient was a 79-year-old man. The right tibial pilon f...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492198/ https://www.ncbi.nlm.nih.gov/pubmed/37693745 http://dx.doi.org/10.1016/j.tcr.2023.100928 |
_version_ | 1785104200231813120 |
---|---|
author | Yanagisawa, Yohei Kotaki, Tomomi Uesugi, Masafumi Yamazaki, Masashi |
author_facet | Yanagisawa, Yohei Kotaki, Tomomi Uesugi, Masafumi Yamazaki, Masashi |
author_sort | Yanagisawa, Yohei |
collection | PubMed |
description | Tibial pilon fractures are difficult to treat. These fractures are associated with a high frequency of soft tissue complications. Therefore, two-stage surgery and less invasive surgical strategies using external fixation have been reported. The patient was a 79-year-old man. The right tibial pilon fracture was diagnosed as AO/OTA 43C3.1, Rüedi and Allgöwer type 2. He was treated with a low-profile mini-fragment plate and circular (Ilizarov type) external fixation. Herein, we report on a combination of these two methods: circular external fixator with low-profile mini-fragment plate fixation. At 18 months postoperatively, the American Orthopaedic Foot & Ankle Society Ankle-Hindfoot score was a perfect score of 100. Radiographs taken in the loading position showed no narrowing of the joint fissure. There were no soft tissue infections, no plate breakage, no bone fusion, no symptoms of plate irritation, and no need for nail extraction. |
format | Online Article Text |
id | pubmed-10492198 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104921982023-09-10 A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture Yanagisawa, Yohei Kotaki, Tomomi Uesugi, Masafumi Yamazaki, Masashi Trauma Case Rep Case Report Tibial pilon fractures are difficult to treat. These fractures are associated with a high frequency of soft tissue complications. Therefore, two-stage surgery and less invasive surgical strategies using external fixation have been reported. The patient was a 79-year-old man. The right tibial pilon fracture was diagnosed as AO/OTA 43C3.1, Rüedi and Allgöwer type 2. He was treated with a low-profile mini-fragment plate and circular (Ilizarov type) external fixation. Herein, we report on a combination of these two methods: circular external fixator with low-profile mini-fragment plate fixation. At 18 months postoperatively, the American Orthopaedic Foot & Ankle Society Ankle-Hindfoot score was a perfect score of 100. Radiographs taken in the loading position showed no narrowing of the joint fissure. There were no soft tissue infections, no plate breakage, no bone fusion, no symptoms of plate irritation, and no need for nail extraction. Elsevier 2023-09-04 /pmc/articles/PMC10492198/ /pubmed/37693745 http://dx.doi.org/10.1016/j.tcr.2023.100928 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Yanagisawa, Yohei Kotaki, Tomomi Uesugi, Masafumi Yamazaki, Masashi A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture |
title | A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture |
title_full | A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture |
title_fullStr | A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture |
title_full_unstemmed | A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture |
title_short | A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture |
title_sort | case report of circular external fixator with low-profile mini-fragment plate fixation: a combination of two methods for a tibial pilon fracture |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492198/ https://www.ncbi.nlm.nih.gov/pubmed/37693745 http://dx.doi.org/10.1016/j.tcr.2023.100928 |
work_keys_str_mv | AT yanagisawayohei acasereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture AT kotakitomomi acasereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture AT uesugimasafumi acasereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture AT yamazakimasashi acasereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture AT yanagisawayohei casereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture AT kotakitomomi casereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture AT uesugimasafumi casereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture AT yamazakimasashi casereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture |