Cargando…

A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture

Tibial pilon fractures are difficult to treat. These fractures are associated with a high frequency of soft tissue complications. Therefore, two-stage surgery and less invasive surgical strategies using external fixation have been reported. The patient was a 79-year-old man. The right tibial pilon f...

Descripción completa

Detalles Bibliográficos
Autores principales: Yanagisawa, Yohei, Kotaki, Tomomi, Uesugi, Masafumi, Yamazaki, Masashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492198/
https://www.ncbi.nlm.nih.gov/pubmed/37693745
http://dx.doi.org/10.1016/j.tcr.2023.100928
_version_ 1785104200231813120
author Yanagisawa, Yohei
Kotaki, Tomomi
Uesugi, Masafumi
Yamazaki, Masashi
author_facet Yanagisawa, Yohei
Kotaki, Tomomi
Uesugi, Masafumi
Yamazaki, Masashi
author_sort Yanagisawa, Yohei
collection PubMed
description Tibial pilon fractures are difficult to treat. These fractures are associated with a high frequency of soft tissue complications. Therefore, two-stage surgery and less invasive surgical strategies using external fixation have been reported. The patient was a 79-year-old man. The right tibial pilon fracture was diagnosed as AO/OTA 43C3.1, Rüedi and Allgöwer type 2. He was treated with a low-profile mini-fragment plate and circular (Ilizarov type) external fixation. Herein, we report on a combination of these two methods: circular external fixator with low-profile mini-fragment plate fixation. At 18 months postoperatively, the American Orthopaedic Foot & Ankle Society Ankle-Hindfoot score was a perfect score of 100. Radiographs taken in the loading position showed no narrowing of the joint fissure. There were no soft tissue infections, no plate breakage, no bone fusion, no symptoms of plate irritation, and no need for nail extraction.
format Online
Article
Text
id pubmed-10492198
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104921982023-09-10 A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture Yanagisawa, Yohei Kotaki, Tomomi Uesugi, Masafumi Yamazaki, Masashi Trauma Case Rep Case Report Tibial pilon fractures are difficult to treat. These fractures are associated with a high frequency of soft tissue complications. Therefore, two-stage surgery and less invasive surgical strategies using external fixation have been reported. The patient was a 79-year-old man. The right tibial pilon fracture was diagnosed as AO/OTA 43C3.1, Rüedi and Allgöwer type 2. He was treated with a low-profile mini-fragment plate and circular (Ilizarov type) external fixation. Herein, we report on a combination of these two methods: circular external fixator with low-profile mini-fragment plate fixation. At 18 months postoperatively, the American Orthopaedic Foot & Ankle Society Ankle-Hindfoot score was a perfect score of 100. Radiographs taken in the loading position showed no narrowing of the joint fissure. There were no soft tissue infections, no plate breakage, no bone fusion, no symptoms of plate irritation, and no need for nail extraction. Elsevier 2023-09-04 /pmc/articles/PMC10492198/ /pubmed/37693745 http://dx.doi.org/10.1016/j.tcr.2023.100928 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Yanagisawa, Yohei
Kotaki, Tomomi
Uesugi, Masafumi
Yamazaki, Masashi
A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture
title A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture
title_full A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture
title_fullStr A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture
title_full_unstemmed A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture
title_short A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture
title_sort case report of circular external fixator with low-profile mini-fragment plate fixation: a combination of two methods for a tibial pilon fracture
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492198/
https://www.ncbi.nlm.nih.gov/pubmed/37693745
http://dx.doi.org/10.1016/j.tcr.2023.100928
work_keys_str_mv AT yanagisawayohei acasereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture
AT kotakitomomi acasereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture
AT uesugimasafumi acasereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture
AT yamazakimasashi acasereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture
AT yanagisawayohei casereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture
AT kotakitomomi casereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture
AT uesugimasafumi casereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture
AT yamazakimasashi casereportofcircularexternalfixatorwithlowprofileminifragmentplatefixationacombinationoftwomethodsforatibialpilonfracture