Cargando…
A deep-learning system to help make the surgical planning of coil embolization for unruptured intracranial aneurysms
BACKGROUND: Coil embolization is a common method for treating unruptured intracranial aneurysms (UIAs). To effectively perform coil embolization for UIAs, clinicians must undergo extensive training with the assistance of senior physicians over an extended period. This study aimed to establish a deep...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10494453/ https://www.ncbi.nlm.nih.gov/pubmed/37691095 http://dx.doi.org/10.1186/s41016-023-00339-y |
Sumario: | BACKGROUND: Coil embolization is a common method for treating unruptured intracranial aneurysms (UIAs). To effectively perform coil embolization for UIAs, clinicians must undergo extensive training with the assistance of senior physicians over an extended period. This study aimed to establish a deep-learning system for measuring the morphological features of UIAs and help the surgical planning of coil embolization for UIAs. METHODS: Preoperative computational tomography angiography (CTA) data and surgical data from UIA patients receiving coil embolization in our medical institution were retrospectively reviewed. A convolutional neural network (CNN) model was trained on the preoperative CTA data, and the morphological features of UIAs were measured automatically using this CNN model. The intraclass correlation coefficient (ICC) was utilized to examine the similarity between the morphologies measured by the CNN model and those determined by experienced clinicians. A deep neural network model to determine the diameter of first coil was further established based on the CNN model within the derivation set (75% of all patients) using neural factorization machines (NFM) model and was validated using a validation set (25% of all patients). The general match ratio (the difference was within ± 1 mm) between the predicted diameter of first coil by model and that used in practical scenario was calculated. RESULTS: One-hundred fifty-three UIA patients were enrolled in this study. The CNN model could diagnose UIAs with an accuracy of 0.97. The performance of this CNN model in measuring the morphological features of UIAs (i.e., size, height, neck diameter, dome diameter, and volume) was comparable to the accuracy of senior clinicians (all ICC > 0.85). The diameter of first coil predicted by the model established based on CNN model and the diameter of first coil used actually exhibited a high general match ratio (0.90) within the derivation set. Moreover, the model performed well in recommending the diameter of first coil within the validation set (general match ratio as 0.91). CONCLUSION: This study presents a deep-learning system which can help to improve surgical planning of coil embolization for UIAs. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s41016-023-00339-y. |
---|