Cargando…
A Machine Learning Framework Reduces the Manual Workload for Systematic Reviews of the Diagnostic Performance of Prostate Magnetic Resonance Imaging
Prostate magnetic resonance imaging has become the imaging standard for prostate cancer in various clinical settings, with interpretation standardized according to the Prostate Imaging Reporting and Data System (PI-RADS). Each year, hundreds of scientific studies that report on the diagnostic perfor...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10495598/ https://www.ncbi.nlm.nih.gov/pubmed/37705517 http://dx.doi.org/10.1016/j.euros.2023.07.005 |
_version_ | 1785104932524785664 |
---|---|
author | Nedelcu, Andrea Oerther, Benedict Engel, Hannes Sigle, August Schmucker, Christine Schoots, Ivo G. Eisenblätter, Michel Benndorf, Matthias |
author_facet | Nedelcu, Andrea Oerther, Benedict Engel, Hannes Sigle, August Schmucker, Christine Schoots, Ivo G. Eisenblätter, Michel Benndorf, Matthias |
author_sort | Nedelcu, Andrea |
collection | PubMed |
description | Prostate magnetic resonance imaging has become the imaging standard for prostate cancer in various clinical settings, with interpretation standardized according to the Prostate Imaging Reporting and Data System (PI-RADS). Each year, hundreds of scientific studies that report on the diagnostic performance of PI-RADS are published. To keep up with this ever-increasing evidence base, systematic reviews and meta-analyses are essential. As systematic reviews are highly resource-intensive, we investigated whether a machine learning framework can reduce the manual workload and speed up the screening process (title and abstract). We used search results from a living systematic review of the diagnostic performance of PI-RADS (1585 studies, of which 482 were potentially eligible after screening). A naïve Bayesian classifier was implemented in an active learning environment for classification of the titles and abstracts. Our outcome variable was the percentage of studies that can be excluded after 95% of relevant studies have been identified by the classifier (work saved over sampling: WSS@95%). In simulation runs of the entire screening process (controlling for classifier initiation and the frequency of classifier updating), we obtained a WSS@95% value of 28% (standard error of the mean ±0.1%). Applied prospectively, our classification framework would translate into a significant reduction in manual screening effort. PATIENT SUMMARY: Systematic reviews of scientific evidence are labor-intensive and take a lot of time. For example, many studies on prostate cancer diagnosis via MRI (magnetic resonance imaging) are published every year. We describe the use of machine learning to reduce the manual workload in screening search results. For a review of MRI for prostate cancer diagnosis, this approach reduced the screening workload by about 28%. |
format | Online Article Text |
id | pubmed-10495598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104955982023-09-13 A Machine Learning Framework Reduces the Manual Workload for Systematic Reviews of the Diagnostic Performance of Prostate Magnetic Resonance Imaging Nedelcu, Andrea Oerther, Benedict Engel, Hannes Sigle, August Schmucker, Christine Schoots, Ivo G. Eisenblätter, Michel Benndorf, Matthias Eur Urol Open Sci Brief Correspondence Prostate magnetic resonance imaging has become the imaging standard for prostate cancer in various clinical settings, with interpretation standardized according to the Prostate Imaging Reporting and Data System (PI-RADS). Each year, hundreds of scientific studies that report on the diagnostic performance of PI-RADS are published. To keep up with this ever-increasing evidence base, systematic reviews and meta-analyses are essential. As systematic reviews are highly resource-intensive, we investigated whether a machine learning framework can reduce the manual workload and speed up the screening process (title and abstract). We used search results from a living systematic review of the diagnostic performance of PI-RADS (1585 studies, of which 482 were potentially eligible after screening). A naïve Bayesian classifier was implemented in an active learning environment for classification of the titles and abstracts. Our outcome variable was the percentage of studies that can be excluded after 95% of relevant studies have been identified by the classifier (work saved over sampling: WSS@95%). In simulation runs of the entire screening process (controlling for classifier initiation and the frequency of classifier updating), we obtained a WSS@95% value of 28% (standard error of the mean ±0.1%). Applied prospectively, our classification framework would translate into a significant reduction in manual screening effort. PATIENT SUMMARY: Systematic reviews of scientific evidence are labor-intensive and take a lot of time. For example, many studies on prostate cancer diagnosis via MRI (magnetic resonance imaging) are published every year. We describe the use of machine learning to reduce the manual workload in screening search results. For a review of MRI for prostate cancer diagnosis, this approach reduced the screening workload by about 28%. Elsevier 2023-08-30 /pmc/articles/PMC10495598/ /pubmed/37705517 http://dx.doi.org/10.1016/j.euros.2023.07.005 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Brief Correspondence Nedelcu, Andrea Oerther, Benedict Engel, Hannes Sigle, August Schmucker, Christine Schoots, Ivo G. Eisenblätter, Michel Benndorf, Matthias A Machine Learning Framework Reduces the Manual Workload for Systematic Reviews of the Diagnostic Performance of Prostate Magnetic Resonance Imaging |
title | A Machine Learning Framework Reduces the Manual Workload for Systematic Reviews of the Diagnostic Performance of Prostate Magnetic Resonance Imaging |
title_full | A Machine Learning Framework Reduces the Manual Workload for Systematic Reviews of the Diagnostic Performance of Prostate Magnetic Resonance Imaging |
title_fullStr | A Machine Learning Framework Reduces the Manual Workload for Systematic Reviews of the Diagnostic Performance of Prostate Magnetic Resonance Imaging |
title_full_unstemmed | A Machine Learning Framework Reduces the Manual Workload for Systematic Reviews of the Diagnostic Performance of Prostate Magnetic Resonance Imaging |
title_short | A Machine Learning Framework Reduces the Manual Workload for Systematic Reviews of the Diagnostic Performance of Prostate Magnetic Resonance Imaging |
title_sort | machine learning framework reduces the manual workload for systematic reviews of the diagnostic performance of prostate magnetic resonance imaging |
topic | Brief Correspondence |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10495598/ https://www.ncbi.nlm.nih.gov/pubmed/37705517 http://dx.doi.org/10.1016/j.euros.2023.07.005 |
work_keys_str_mv | AT nedelcuandrea amachinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT oertherbenedict amachinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT engelhannes amachinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT sigleaugust amachinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT schmuckerchristine amachinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT schootsivog amachinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT eisenblattermichel amachinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT benndorfmatthias amachinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT nedelcuandrea machinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT oertherbenedict machinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT engelhannes machinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT sigleaugust machinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT schmuckerchristine machinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT schootsivog machinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT eisenblattermichel machinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging AT benndorfmatthias machinelearningframeworkreducesthemanualworkloadforsystematicreviewsofthediagnosticperformanceofprostatemagneticresonanceimaging |