Cargando…
Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
BACKGROUND: Calcaneal fractures are the most common tarsal bone fractures, and account for 75% of intra-articular fractures. The purpose of this study was to compare the biomechanical stability of the anterior process locking plate combined with the percutaneous cannulated screw fixation (screw grou...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10496517/ https://www.ncbi.nlm.nih.gov/pubmed/37674308 http://dx.doi.org/10.12659/MSM.940300 |
_version_ | 1785105118716231680 |
---|---|
author | Ma, Rongji Shaikh, Atik Badshah Zhang, Qinxin Su, Xiuyun Wang, Yonghua Pan, Fuhai Chen, Jianwen He, Kai |
author_facet | Ma, Rongji Shaikh, Atik Badshah Zhang, Qinxin Su, Xiuyun Wang, Yonghua Pan, Fuhai Chen, Jianwen He, Kai |
author_sort | Ma, Rongji |
collection | PubMed |
description | BACKGROUND: Calcaneal fractures are the most common tarsal bone fractures, and account for 75% of intra-articular fractures. The purpose of this study was to compare the biomechanical stability of the anterior process locking plate combined with the percutaneous cannulated screw fixation (screw group) versus the anterior process locking plate fixation alone (plate group) for the treatment of Sanders type II calcaneal fractures using finite element analysis to provide a theoretical basis for clinical work. MATERIAL/METHODS: We established a 3D model of Sanders type II calcaneal fracture; assigned material properties to the internal fixation systems; applied loads; set up analysis criteria; analyzed the displacement of the fracture, relative displacement, stress state of bone tissue, and internal fixation; and compared mechanical stability. RESULTS: For Sanders type II A, II B, and II C calcaneal fractures, the degree of displacement and relative displacement of the fracture in the screw group was less than that of the plate group. For all subtypes of Sanders type II calcaneal fractures, the screw group had better mechanical stability than the plate group. CONCLUSIONS: Both fixation methods (screw and plate group) were within a reasonable range for restoring the levelling effect of the joint surface and maintaining the strength of fixation, and both had good mechanical stability. Finite element analysis is a relatively reliable method, and biomechanics and clinical studies must further verify the experimental results. |
format | Online Article Text |
id | pubmed-10496517 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-104965172023-09-13 Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study Ma, Rongji Shaikh, Atik Badshah Zhang, Qinxin Su, Xiuyun Wang, Yonghua Pan, Fuhai Chen, Jianwen He, Kai Med Sci Monit Clinical Research BACKGROUND: Calcaneal fractures are the most common tarsal bone fractures, and account for 75% of intra-articular fractures. The purpose of this study was to compare the biomechanical stability of the anterior process locking plate combined with the percutaneous cannulated screw fixation (screw group) versus the anterior process locking plate fixation alone (plate group) for the treatment of Sanders type II calcaneal fractures using finite element analysis to provide a theoretical basis for clinical work. MATERIAL/METHODS: We established a 3D model of Sanders type II calcaneal fracture; assigned material properties to the internal fixation systems; applied loads; set up analysis criteria; analyzed the displacement of the fracture, relative displacement, stress state of bone tissue, and internal fixation; and compared mechanical stability. RESULTS: For Sanders type II A, II B, and II C calcaneal fractures, the degree of displacement and relative displacement of the fracture in the screw group was less than that of the plate group. For all subtypes of Sanders type II calcaneal fractures, the screw group had better mechanical stability than the plate group. CONCLUSIONS: Both fixation methods (screw and plate group) were within a reasonable range for restoring the levelling effect of the joint surface and maintaining the strength of fixation, and both had good mechanical stability. Finite element analysis is a relatively reliable method, and biomechanics and clinical studies must further verify the experimental results. International Scientific Literature, Inc. 2023-09-07 /pmc/articles/PMC10496517/ /pubmed/37674308 http://dx.doi.org/10.12659/MSM.940300 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Clinical Research Ma, Rongji Shaikh, Atik Badshah Zhang, Qinxin Su, Xiuyun Wang, Yonghua Pan, Fuhai Chen, Jianwen He, Kai Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study |
title | Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study |
title_full | Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study |
title_fullStr | Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study |
title_full_unstemmed | Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study |
title_short | Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study |
title_sort | comparative biomechanical analysis of anterior process locking plate alone versus combined with percutaneous cannulated screw fixation for sanders type ii calcaneal fractures: a finite element study |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10496517/ https://www.ncbi.nlm.nih.gov/pubmed/37674308 http://dx.doi.org/10.12659/MSM.940300 |
work_keys_str_mv | AT marongji comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy AT shaikhatikbadshah comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy AT zhangqinxin comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy AT suxiuyun comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy AT wangyonghua comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy AT panfuhai comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy AT chenjianwen comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy AT hekai comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy |