Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study

BACKGROUND: Calcaneal fractures are the most common tarsal bone fractures, and account for 75% of intra-articular fractures. The purpose of this study was to compare the biomechanical stability of the anterior process locking plate combined with the percutaneous cannulated screw fixation (screw grou...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Rongji, Shaikh, Atik Badshah, Zhang, Qinxin, Su, Xiuyun, Wang, Yonghua, Pan, Fuhai, Chen, Jianwen, He, Kai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10496517/
https://www.ncbi.nlm.nih.gov/pubmed/37674308
http://dx.doi.org/10.12659/MSM.940300
_version_ 1785105118716231680
author Ma, Rongji
Shaikh, Atik Badshah
Zhang, Qinxin
Su, Xiuyun
Wang, Yonghua
Pan, Fuhai
Chen, Jianwen
He, Kai
author_facet Ma, Rongji
Shaikh, Atik Badshah
Zhang, Qinxin
Su, Xiuyun
Wang, Yonghua
Pan, Fuhai
Chen, Jianwen
He, Kai
author_sort Ma, Rongji
collection PubMed
description BACKGROUND: Calcaneal fractures are the most common tarsal bone fractures, and account for 75% of intra-articular fractures. The purpose of this study was to compare the biomechanical stability of the anterior process locking plate combined with the percutaneous cannulated screw fixation (screw group) versus the anterior process locking plate fixation alone (plate group) for the treatment of Sanders type II calcaneal fractures using finite element analysis to provide a theoretical basis for clinical work. MATERIAL/METHODS: We established a 3D model of Sanders type II calcaneal fracture; assigned material properties to the internal fixation systems; applied loads; set up analysis criteria; analyzed the displacement of the fracture, relative displacement, stress state of bone tissue, and internal fixation; and compared mechanical stability. RESULTS: For Sanders type II A, II B, and II C calcaneal fractures, the degree of displacement and relative displacement of the fracture in the screw group was less than that of the plate group. For all subtypes of Sanders type II calcaneal fractures, the screw group had better mechanical stability than the plate group. CONCLUSIONS: Both fixation methods (screw and plate group) were within a reasonable range for restoring the levelling effect of the joint surface and maintaining the strength of fixation, and both had good mechanical stability. Finite element analysis is a relatively reliable method, and biomechanics and clinical studies must further verify the experimental results.
format Online
Article
Text
id pubmed-10496517
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-104965172023-09-13 Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study Ma, Rongji Shaikh, Atik Badshah Zhang, Qinxin Su, Xiuyun Wang, Yonghua Pan, Fuhai Chen, Jianwen He, Kai Med Sci Monit Clinical Research BACKGROUND: Calcaneal fractures are the most common tarsal bone fractures, and account for 75% of intra-articular fractures. The purpose of this study was to compare the biomechanical stability of the anterior process locking plate combined with the percutaneous cannulated screw fixation (screw group) versus the anterior process locking plate fixation alone (plate group) for the treatment of Sanders type II calcaneal fractures using finite element analysis to provide a theoretical basis for clinical work. MATERIAL/METHODS: We established a 3D model of Sanders type II calcaneal fracture; assigned material properties to the internal fixation systems; applied loads; set up analysis criteria; analyzed the displacement of the fracture, relative displacement, stress state of bone tissue, and internal fixation; and compared mechanical stability. RESULTS: For Sanders type II A, II B, and II C calcaneal fractures, the degree of displacement and relative displacement of the fracture in the screw group was less than that of the plate group. For all subtypes of Sanders type II calcaneal fractures, the screw group had better mechanical stability than the plate group. CONCLUSIONS: Both fixation methods (screw and plate group) were within a reasonable range for restoring the levelling effect of the joint surface and maintaining the strength of fixation, and both had good mechanical stability. Finite element analysis is a relatively reliable method, and biomechanics and clinical studies must further verify the experimental results. International Scientific Literature, Inc. 2023-09-07 /pmc/articles/PMC10496517/ /pubmed/37674308 http://dx.doi.org/10.12659/MSM.940300 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Ma, Rongji
Shaikh, Atik Badshah
Zhang, Qinxin
Su, Xiuyun
Wang, Yonghua
Pan, Fuhai
Chen, Jianwen
He, Kai
Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
title Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
title_full Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
title_fullStr Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
title_full_unstemmed Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
title_short Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
title_sort comparative biomechanical analysis of anterior process locking plate alone versus combined with percutaneous cannulated screw fixation for sanders type ii calcaneal fractures: a finite element study
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10496517/
https://www.ncbi.nlm.nih.gov/pubmed/37674308
http://dx.doi.org/10.12659/MSM.940300
work_keys_str_mv AT marongji comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy
AT shaikhatikbadshah comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy
AT zhangqinxin comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy
AT suxiuyun comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy
AT wangyonghua comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy
AT panfuhai comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy
AT chenjianwen comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy
AT hekai comparativebiomechanicalanalysisofanteriorprocesslockingplatealoneversuscombinedwithpercutaneouscannulatedscrewfixationforsanderstypeiicalcanealfracturesafiniteelementstudy