Cargando…

Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching

BACKGROUND: The transosseous anchorless repair (ToR) technique was recently introduced to avoid suture anchor-related problems. While favorable outcomes of the ToR technique have been reported, no previous studies on peri-implant cyst formation with the ToR technique exist. Therefore, this study com...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Hyeon Jang, Lee, Ji Soo, Kim, Young Kyu, Rhee, Sung-Min, Oh, Joo Han
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Shoulder and Elbow Society 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10497926/
https://www.ncbi.nlm.nih.gov/pubmed/37559521
http://dx.doi.org/10.5397/cise.2023.00052
_version_ 1785105409113063424
author Jeong, Hyeon Jang
Lee, Ji Soo
Kim, Young Kyu
Rhee, Sung-Min
Oh, Joo Han
author_facet Jeong, Hyeon Jang
Lee, Ji Soo
Kim, Young Kyu
Rhee, Sung-Min
Oh, Joo Han
author_sort Jeong, Hyeon Jang
collection PubMed
description BACKGROUND: The transosseous anchorless repair (ToR) technique was recently introduced to avoid suture anchor-related problems. While favorable outcomes of the ToR technique have been reported, no previous studies on peri-implant cyst formation with the ToR technique exist. Therefore, this study compared the clinical outcomes and prevalence of peri-implant cyst formation between the ToR technique and the conventional transosseous equivalent technique using suture anchors (SA). METHODS: Cases with arthroscopic rotator cuff repair (ARCR) between 2016 and 2018 treated with the double-row suture bridge technique were retrospectively reviewed. Patients were divided into ToR and SA groups. To compare clinical outcomes, 19 ToR and 57 SA cases without intraoperative implant failure were selected using propensity score matching (PSM). While intraoperative implant failure rate was analyzed before PSM, retear rate, peri-implant cyst formation rate, and functional outcomes were compared after PSM. RESULTS: The intraoperative implant failure rate (ToR, 8% vs. SA, 15.3%) and retear rate (ToR, 5.3% vs. SA, 19.3%) did not differ between the two groups (all P>0.05). However, peri-implant cysts were not observed in the ToR group, while they were observed in 16.7% of the SA group (P=0.008). Postoperative functional outcomes were not significantly different between the two groups (all P>0.05). CONCLUSIONS: The ToR technique produced comparable clinical outcomes to conventional techniques. Considering the prospect of potential additional surgeries, the absence of peri-implant cyst formation might be an advantage of ToR. Furthermore, ToR might reduce the medical costs related to suture anchors and, thereby, could be a useful option for ARCR. LEVEL OF EVIDENCE: III.
format Online
Article
Text
id pubmed-10497926
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Korean Shoulder and Elbow Society
record_format MEDLINE/PubMed
spelling pubmed-104979262023-09-14 Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching Jeong, Hyeon Jang Lee, Ji Soo Kim, Young Kyu Rhee, Sung-Min Oh, Joo Han Clin Shoulder Elb Original Article BACKGROUND: The transosseous anchorless repair (ToR) technique was recently introduced to avoid suture anchor-related problems. While favorable outcomes of the ToR technique have been reported, no previous studies on peri-implant cyst formation with the ToR technique exist. Therefore, this study compared the clinical outcomes and prevalence of peri-implant cyst formation between the ToR technique and the conventional transosseous equivalent technique using suture anchors (SA). METHODS: Cases with arthroscopic rotator cuff repair (ARCR) between 2016 and 2018 treated with the double-row suture bridge technique were retrospectively reviewed. Patients were divided into ToR and SA groups. To compare clinical outcomes, 19 ToR and 57 SA cases without intraoperative implant failure were selected using propensity score matching (PSM). While intraoperative implant failure rate was analyzed before PSM, retear rate, peri-implant cyst formation rate, and functional outcomes were compared after PSM. RESULTS: The intraoperative implant failure rate (ToR, 8% vs. SA, 15.3%) and retear rate (ToR, 5.3% vs. SA, 19.3%) did not differ between the two groups (all P>0.05). However, peri-implant cysts were not observed in the ToR group, while they were observed in 16.7% of the SA group (P=0.008). Postoperative functional outcomes were not significantly different between the two groups (all P>0.05). CONCLUSIONS: The ToR technique produced comparable clinical outcomes to conventional techniques. Considering the prospect of potential additional surgeries, the absence of peri-implant cyst formation might be an advantage of ToR. Furthermore, ToR might reduce the medical costs related to suture anchors and, thereby, could be a useful option for ARCR. LEVEL OF EVIDENCE: III. Korean Shoulder and Elbow Society 2023-08-10 /pmc/articles/PMC10497926/ /pubmed/37559521 http://dx.doi.org/10.5397/cise.2023.00052 Text en Copyright © 2023 Korean Shoulder and Elbow Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jeong, Hyeon Jang
Lee, Ji Soo
Kim, Young Kyu
Rhee, Sung-Min
Oh, Joo Han
Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching
title Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching
title_full Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching
title_fullStr Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching
title_full_unstemmed Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching
title_short Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching
title_sort arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10497926/
https://www.ncbi.nlm.nih.gov/pubmed/37559521
http://dx.doi.org/10.5397/cise.2023.00052
work_keys_str_mv AT jeonghyeonjang arthroscopictransosseousanchorlessrotatorcuffrepairreducesbonedefectsrelatedtoperiimplantcystformationacomparisonwithconventionalsutureanchorsusingpropensityscorematching
AT leejisoo arthroscopictransosseousanchorlessrotatorcuffrepairreducesbonedefectsrelatedtoperiimplantcystformationacomparisonwithconventionalsutureanchorsusingpropensityscorematching
AT kimyoungkyu arthroscopictransosseousanchorlessrotatorcuffrepairreducesbonedefectsrelatedtoperiimplantcystformationacomparisonwithconventionalsutureanchorsusingpropensityscorematching
AT rheesungmin arthroscopictransosseousanchorlessrotatorcuffrepairreducesbonedefectsrelatedtoperiimplantcystformationacomparisonwithconventionalsutureanchorsusingpropensityscorematching
AT ohjoohan arthroscopictransosseousanchorlessrotatorcuffrepairreducesbonedefectsrelatedtoperiimplantcystformationacomparisonwithconventionalsutureanchorsusingpropensityscorematching