Feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study

BACKGROUND: Most patients undergoing left atrial appendage closure (LAAC) are older adult individuals with atrial fibrillation (AF) and many comorbidities, which may elevate the risk for complications associated with contrast agents with the fluoroscopic image-guided procedure. This retrospective co...

Descripción completa

Detalles Bibliográficos
Autores principales: Zou, Mengxuan, Zhuang, Donglin, Sievert, Horst, Lam, Yat-Yin, Zhao, Guangzhi, Ouyang, Wenbin, Zhang, Fengwen, Fang, Fang, Zhang, Deyuan, Li, Anning, Pan, Xiangbin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10498255/
https://www.ncbi.nlm.nih.gov/pubmed/37711838
http://dx.doi.org/10.21037/qims-23-169
_version_ 1785105481019162624
author Zou, Mengxuan
Zhuang, Donglin
Sievert, Horst
Lam, Yat-Yin
Zhao, Guangzhi
Ouyang, Wenbin
Zhang, Fengwen
Fang, Fang
Zhang, Deyuan
Li, Anning
Pan, Xiangbin
author_facet Zou, Mengxuan
Zhuang, Donglin
Sievert, Horst
Lam, Yat-Yin
Zhao, Guangzhi
Ouyang, Wenbin
Zhang, Fengwen
Fang, Fang
Zhang, Deyuan
Li, Anning
Pan, Xiangbin
author_sort Zou, Mengxuan
collection PubMed
description BACKGROUND: Most patients undergoing left atrial appendage closure (LAAC) are older adult individuals with atrial fibrillation (AF) and many comorbidities, which may elevate the risk for complications associated with contrast agents with the fluoroscopic image-guided procedure. This retrospective cohort study of patients with AF at high risk for use of contrast agents compared the feasibility and safety of LAAC using percutaneous and non-fluoroscopic procedure with transesophageal echocardiography (TEE) as the only image guidance relative to those under fluoroscopic image guidance. METHODS: In this retrospective study, we enrolled 126 patients with AF who underwent LAAC from September 2017 to December 2020. Patients were divided into 2 groups based on the imaging guidance modality: a TEE group (n=32) and a fluoroscopic group (n=94). We analyzed the differences in complete closure rates and device- and procedure-related complications between the 2 groups. Continuous variables were assessed using the Student t-test or Mann-Whitney test, while categorical variables were evaluated using Pearson chi-squared test or Fisher exact test. Propensity-score matching was used to adjust for baseline differences. RESULTS: Propensity-score matching yielded 25 pairs of patients with similarly distributed age (72.9±6.9 vs. 73.1±4.9 years; P=0.925), gender (10:15 vs. 11:14; P>0.99), weight (68.3±11.2 vs. 68.1±12.3 kg; P=0.948), and alanine aminotransferase level (20.0±9.8 vs. 22.5±14.2 U/L; P=0.482). The LAA was successfully occluded in all patients, and the TEE group showed similar results to the fluoroscopic group in terms of success rate (100% vs. 100%; P>0.99) and hospitalization duration [5.0 (IQ1–IQ3: 3.0–7.0) vs. 5.0 (IQ1–IQ3: 3.0–6.0) days; P=0.498]. The groups also demonstrated comparable complication rates, with 1 (4.2%) case of pericardial effusion and 1 (4.2%) case of residual shunt in the TEE group, and 5 (20%) cases of residual shunt, 1 (4.2%) case of pericardial effusion, 1 (4.2%) case of myocardial infarction, and 1 (4.2%) case of access-related complications in the fluoroscopic group. There were no deaths. The overall incidence rate of procedure-related complications (6.2% vs. 18.1%, P=0.153) at mean 22.2±4.5 months follow-up between the 2 groups was similar. CONCLUSIONS: In patients with AF of high risk for use of contrast agents, LAAC under non-fluoroscopic guidance appears feasible and safe with similar outcomes to that under fluoroscopic guidance.
format Online
Article
Text
id pubmed-10498255
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-104982552023-09-14 Feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study Zou, Mengxuan Zhuang, Donglin Sievert, Horst Lam, Yat-Yin Zhao, Guangzhi Ouyang, Wenbin Zhang, Fengwen Fang, Fang Zhang, Deyuan Li, Anning Pan, Xiangbin Quant Imaging Med Surg Original Article BACKGROUND: Most patients undergoing left atrial appendage closure (LAAC) are older adult individuals with atrial fibrillation (AF) and many comorbidities, which may elevate the risk for complications associated with contrast agents with the fluoroscopic image-guided procedure. This retrospective cohort study of patients with AF at high risk for use of contrast agents compared the feasibility and safety of LAAC using percutaneous and non-fluoroscopic procedure with transesophageal echocardiography (TEE) as the only image guidance relative to those under fluoroscopic image guidance. METHODS: In this retrospective study, we enrolled 126 patients with AF who underwent LAAC from September 2017 to December 2020. Patients were divided into 2 groups based on the imaging guidance modality: a TEE group (n=32) and a fluoroscopic group (n=94). We analyzed the differences in complete closure rates and device- and procedure-related complications between the 2 groups. Continuous variables were assessed using the Student t-test or Mann-Whitney test, while categorical variables were evaluated using Pearson chi-squared test or Fisher exact test. Propensity-score matching was used to adjust for baseline differences. RESULTS: Propensity-score matching yielded 25 pairs of patients with similarly distributed age (72.9±6.9 vs. 73.1±4.9 years; P=0.925), gender (10:15 vs. 11:14; P>0.99), weight (68.3±11.2 vs. 68.1±12.3 kg; P=0.948), and alanine aminotransferase level (20.0±9.8 vs. 22.5±14.2 U/L; P=0.482). The LAA was successfully occluded in all patients, and the TEE group showed similar results to the fluoroscopic group in terms of success rate (100% vs. 100%; P>0.99) and hospitalization duration [5.0 (IQ1–IQ3: 3.0–7.0) vs. 5.0 (IQ1–IQ3: 3.0–6.0) days; P=0.498]. The groups also demonstrated comparable complication rates, with 1 (4.2%) case of pericardial effusion and 1 (4.2%) case of residual shunt in the TEE group, and 5 (20%) cases of residual shunt, 1 (4.2%) case of pericardial effusion, 1 (4.2%) case of myocardial infarction, and 1 (4.2%) case of access-related complications in the fluoroscopic group. There were no deaths. The overall incidence rate of procedure-related complications (6.2% vs. 18.1%, P=0.153) at mean 22.2±4.5 months follow-up between the 2 groups was similar. CONCLUSIONS: In patients with AF of high risk for use of contrast agents, LAAC under non-fluoroscopic guidance appears feasible and safe with similar outcomes to that under fluoroscopic guidance. AME Publishing Company 2023-08-23 2023-09-01 /pmc/articles/PMC10498255/ /pubmed/37711838 http://dx.doi.org/10.21037/qims-23-169 Text en 2023 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Zou, Mengxuan
Zhuang, Donglin
Sievert, Horst
Lam, Yat-Yin
Zhao, Guangzhi
Ouyang, Wenbin
Zhang, Fengwen
Fang, Fang
Zhang, Deyuan
Li, Anning
Pan, Xiangbin
Feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study
title Feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study
title_full Feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study
title_fullStr Feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study
title_full_unstemmed Feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study
title_short Feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study
title_sort feasibility and safety of a percutaneous and non-fluoroscopic procedure for left atrial appendage closure in patients for whom fluoroscopy presents risk: a cohort study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10498255/
https://www.ncbi.nlm.nih.gov/pubmed/37711838
http://dx.doi.org/10.21037/qims-23-169
work_keys_str_mv AT zoumengxuan feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT zhuangdonglin feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT sieverthorst feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT lamyatyin feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT zhaoguangzhi feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT ouyangwenbin feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT zhangfengwen feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT fangfang feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT zhangdeyuan feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT lianning feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy
AT panxiangbin feasibilityandsafetyofapercutaneousandnonfluoroscopicprocedureforleftatrialappendageclosureinpatientsforwhomfluoroscopypresentsriskacohortstudy