Cargando…
Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging
INTRODUCTION: Advanced chronic kidney disease (CKD) is an independent risk factor for coronary artery disease (CAD). Due to its unique uremia-derived pathophysiology of atherosclerosis and the limitations of using potentially harmful contrast agents, the best non-invasive approach to assess CAD in t...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10498284/ https://www.ncbi.nlm.nih.gov/pubmed/37711564 http://dx.doi.org/10.3389/fcvm.2023.1228691 |
_version_ | 1785105488000581632 |
---|---|
author | Weberling, Lukas D. Seitz, Sebastian Salatzki, Janek Ochs, Andreas Haney, Ailís C. Siry, Deborah Heins, Jannick Steen, Henning Frey, Norbert André, Florian |
author_facet | Weberling, Lukas D. Seitz, Sebastian Salatzki, Janek Ochs, Andreas Haney, Ailís C. Siry, Deborah Heins, Jannick Steen, Henning Frey, Norbert André, Florian |
author_sort | Weberling, Lukas D. |
collection | PubMed |
description | INTRODUCTION: Advanced chronic kidney disease (CKD) is an independent risk factor for coronary artery disease (CAD). Due to its unique uremia-derived pathophysiology of atherosclerosis and the limitations of using potentially harmful contrast agents, the best non-invasive approach to assess CAD in these patients remains unclear. We sought to investigate the accuracy, safety, and prognosis of patients with severe CKD undergoing dobutamine stress cardiac magnetic resonance imaging (CMR). MATERIALS AND METHODS: In this retrospective, single-center study, patients on dialysis or with a glomerular filtration rate of <15 ml/min/1.73 m(2) who underwent dobutamine stress CMR were included. A rest and stress wall motion analysis was performed using dobutamine/atropine as stressor. The target heart rate was 85% of the maximum heart rate. Periprocedural adverse events and 1-year follow-up data were obtained. RESULTS: A total of 176 patients (127 men, 49 women) with a mean age of 60.9 ± 14.7 years were included, of which 156 patients were on permanent dialysis. Short-term symptoms such as angina or shortness of breath during stress CMR were frequent (22.1%), but major complications were rare (one patient with myocardial infarction, 0.6%). The 1-year event rate was high (16.4%) with a significant independent correlation to reduced ejection fraction at rest (p = 0.037) and failure to achieve the target heart rate (p = 0.029). The overall accuracy for predicting significant CAD was good (sensitivity of 71.4%, specificity of 98.4%) and excellent if the target heart rate was achieved (83.3%, 97.9%). A negative stress CMR was highly predictive for the absence of major adverse cardiac event or any coronary revascularization during the 1-year follow-up (negative predictive value of 95.0%). DISCUSSION: Dobutamine stress CMR is a safe and accurate diagnostic imaging technique in patients at advanced stages of chronic kidney disease. A reduced ejection fraction and the inability to reach the target heart rate are independent predictors of a poor outcome. |
format | Online Article Text |
id | pubmed-10498284 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-104982842023-09-14 Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging Weberling, Lukas D. Seitz, Sebastian Salatzki, Janek Ochs, Andreas Haney, Ailís C. Siry, Deborah Heins, Jannick Steen, Henning Frey, Norbert André, Florian Front Cardiovasc Med Cardiovascular Medicine INTRODUCTION: Advanced chronic kidney disease (CKD) is an independent risk factor for coronary artery disease (CAD). Due to its unique uremia-derived pathophysiology of atherosclerosis and the limitations of using potentially harmful contrast agents, the best non-invasive approach to assess CAD in these patients remains unclear. We sought to investigate the accuracy, safety, and prognosis of patients with severe CKD undergoing dobutamine stress cardiac magnetic resonance imaging (CMR). MATERIALS AND METHODS: In this retrospective, single-center study, patients on dialysis or with a glomerular filtration rate of <15 ml/min/1.73 m(2) who underwent dobutamine stress CMR were included. A rest and stress wall motion analysis was performed using dobutamine/atropine as stressor. The target heart rate was 85% of the maximum heart rate. Periprocedural adverse events and 1-year follow-up data were obtained. RESULTS: A total of 176 patients (127 men, 49 women) with a mean age of 60.9 ± 14.7 years were included, of which 156 patients were on permanent dialysis. Short-term symptoms such as angina or shortness of breath during stress CMR were frequent (22.1%), but major complications were rare (one patient with myocardial infarction, 0.6%). The 1-year event rate was high (16.4%) with a significant independent correlation to reduced ejection fraction at rest (p = 0.037) and failure to achieve the target heart rate (p = 0.029). The overall accuracy for predicting significant CAD was good (sensitivity of 71.4%, specificity of 98.4%) and excellent if the target heart rate was achieved (83.3%, 97.9%). A negative stress CMR was highly predictive for the absence of major adverse cardiac event or any coronary revascularization during the 1-year follow-up (negative predictive value of 95.0%). DISCUSSION: Dobutamine stress CMR is a safe and accurate diagnostic imaging technique in patients at advanced stages of chronic kidney disease. A reduced ejection fraction and the inability to reach the target heart rate are independent predictors of a poor outcome. Frontiers Media S.A. 2023-08-30 /pmc/articles/PMC10498284/ /pubmed/37711564 http://dx.doi.org/10.3389/fcvm.2023.1228691 Text en © 2023 Weberling, Seitz, Salatzki, Ochs, Haney, Siry, Heins, Steen, Frey and André. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Weberling, Lukas D. Seitz, Sebastian Salatzki, Janek Ochs, Andreas Haney, Ailís C. Siry, Deborah Heins, Jannick Steen, Henning Frey, Norbert André, Florian Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging |
title | Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging |
title_full | Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging |
title_fullStr | Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging |
title_full_unstemmed | Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging |
title_short | Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging |
title_sort | safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10498284/ https://www.ncbi.nlm.nih.gov/pubmed/37711564 http://dx.doi.org/10.3389/fcvm.2023.1228691 |
work_keys_str_mv | AT weberlinglukasd safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT seitzsebastian safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT salatzkijanek safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT ochsandreas safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT haneyailisc safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT sirydeborah safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT heinsjannick safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT steenhenning safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT freynorbert safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging AT andreflorian safetyaccuracyandpredictionofprognosisinpatientswithendstagechronickidneydiseaseundergoingdobutaminestresscardiacmagneticresonanceimaging |