Cargando…

Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study

BACKGROUND: Wireless vital sign sensors are increasingly being used to monitor patients on surgical wards. Although early warning scores (EWSs) are the current standard for the identification of patient deterioration in a ward setting, their usefulness for continuous monitoring is unknown. OBJECTIVE...

Descripción completa

Detalles Bibliográficos
Autores principales: van Rossum, Mathilde C, Bekhuis, Robin E M, Wang, Ying, Hegeman, Johannes H, Folbert, Ellis C, Vollenbroek-Hutten, Miriam M R, Kalkman, Cornelis J, Kouwenhoven, Ewout A, Hermens, Hermie J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10500362/
https://www.ncbi.nlm.nih.gov/pubmed/37647104
http://dx.doi.org/10.2196/44483
_version_ 1785105906970656768
author van Rossum, Mathilde C
Bekhuis, Robin E M
Wang, Ying
Hegeman, Johannes H
Folbert, Ellis C
Vollenbroek-Hutten, Miriam M R
Kalkman, Cornelis J
Kouwenhoven, Ewout A
Hermens, Hermie J
author_facet van Rossum, Mathilde C
Bekhuis, Robin E M
Wang, Ying
Hegeman, Johannes H
Folbert, Ellis C
Vollenbroek-Hutten, Miriam M R
Kalkman, Cornelis J
Kouwenhoven, Ewout A
Hermens, Hermie J
author_sort van Rossum, Mathilde C
collection PubMed
description BACKGROUND: Wireless vital sign sensors are increasingly being used to monitor patients on surgical wards. Although early warning scores (EWSs) are the current standard for the identification of patient deterioration in a ward setting, their usefulness for continuous monitoring is unknown. OBJECTIVE: This study aimed to explore the usability and predictive value of high-rate EWSs obtained from continuous vital sign recordings for early identification of postoperative complications and compares the performance of a sensor-based EWS alarm system with manual intermittent EWS measurements and threshold alarms applied to individual vital sign recordings (single-parameter alarms). METHODS: Continuous vital sign measurements (heart rate, respiratory rate, blood oxygen saturation, and axillary temperature) collected with wireless sensors in patients on surgical wards were used for retrospective simulation of EWSs (sensor EWSs) for different time windows (1-240 min), adopting criteria similar to EWSs based on manual vital signs measurements (nurse EWSs). Hourly sensor EWS measurements were compared between patients with (event group: 14/46, 30%) and without (control group: 32/46, 70%) postoperative complications. In addition, alarms were simulated for the sensor EWSs using a range of alarm thresholds (1-9) and compared with alarms based on nurse EWSs and single-parameter alarms. Alarm performance was evaluated using the sensitivity to predict complications within 24 hours, daily alarm rate, and false discovery rate (FDR). RESULTS: The hourly sensor EWSs of the event group (median 3.4, IQR 3.1-4.1) was significantly higher (P<.004) compared with the control group (median 2.8, IQR 2.4-3.2). The alarm sensitivity of the hourly sensor EWSs was the highest (80%-67%) for thresholds of 3 to 5, which was associated with alarm rates of 2 (FDR=85%) to 1.2 (FDR=83%) alarms per patient per day respectively. The sensitivity of sensor EWS–based alarms was higher than that of nurse EWS–based alarms (maximum=40%) but lower than that of single-parameter alarms (87%) for all thresholds. In contrast, the (false) alarm rates of sensor EWS–based alarms were higher than that of nurse EWS–based alarms (maximum=0.6 alarm/patient/d; FDR=80%) but lower than that of single-parameter alarms (2 alarms/patient/d; FDR=84%) for most thresholds. Alarm rates for sensor EWSs increased for shorter time windows, reaching 70 alarms per patient per day when calculated every minute. CONCLUSIONS: EWSs obtained using wireless vital sign sensors may contribute to the early recognition of postoperative complications in a ward setting, with higher alarm sensitivity compared with manual EWS measurements. Although hourly sensor EWSs provide fewer alarms compared with single-parameter alarms, high false alarm rates can be expected when calculated over shorter time spans. Further studies are recommended to optimize care escalation criteria for continuous monitoring of vital signs in a ward setting and to evaluate the effects on patient outcomes.
format Online
Article
Text
id pubmed-10500362
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-105003622023-09-15 Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study van Rossum, Mathilde C Bekhuis, Robin E M Wang, Ying Hegeman, Johannes H Folbert, Ellis C Vollenbroek-Hutten, Miriam M R Kalkman, Cornelis J Kouwenhoven, Ewout A Hermens, Hermie J JMIR Perioper Med Original Paper BACKGROUND: Wireless vital sign sensors are increasingly being used to monitor patients on surgical wards. Although early warning scores (EWSs) are the current standard for the identification of patient deterioration in a ward setting, their usefulness for continuous monitoring is unknown. OBJECTIVE: This study aimed to explore the usability and predictive value of high-rate EWSs obtained from continuous vital sign recordings for early identification of postoperative complications and compares the performance of a sensor-based EWS alarm system with manual intermittent EWS measurements and threshold alarms applied to individual vital sign recordings (single-parameter alarms). METHODS: Continuous vital sign measurements (heart rate, respiratory rate, blood oxygen saturation, and axillary temperature) collected with wireless sensors in patients on surgical wards were used for retrospective simulation of EWSs (sensor EWSs) for different time windows (1-240 min), adopting criteria similar to EWSs based on manual vital signs measurements (nurse EWSs). Hourly sensor EWS measurements were compared between patients with (event group: 14/46, 30%) and without (control group: 32/46, 70%) postoperative complications. In addition, alarms were simulated for the sensor EWSs using a range of alarm thresholds (1-9) and compared with alarms based on nurse EWSs and single-parameter alarms. Alarm performance was evaluated using the sensitivity to predict complications within 24 hours, daily alarm rate, and false discovery rate (FDR). RESULTS: The hourly sensor EWSs of the event group (median 3.4, IQR 3.1-4.1) was significantly higher (P<.004) compared with the control group (median 2.8, IQR 2.4-3.2). The alarm sensitivity of the hourly sensor EWSs was the highest (80%-67%) for thresholds of 3 to 5, which was associated with alarm rates of 2 (FDR=85%) to 1.2 (FDR=83%) alarms per patient per day respectively. The sensitivity of sensor EWS–based alarms was higher than that of nurse EWS–based alarms (maximum=40%) but lower than that of single-parameter alarms (87%) for all thresholds. In contrast, the (false) alarm rates of sensor EWS–based alarms were higher than that of nurse EWS–based alarms (maximum=0.6 alarm/patient/d; FDR=80%) but lower than that of single-parameter alarms (2 alarms/patient/d; FDR=84%) for most thresholds. Alarm rates for sensor EWSs increased for shorter time windows, reaching 70 alarms per patient per day when calculated every minute. CONCLUSIONS: EWSs obtained using wireless vital sign sensors may contribute to the early recognition of postoperative complications in a ward setting, with higher alarm sensitivity compared with manual EWS measurements. Although hourly sensor EWSs provide fewer alarms compared with single-parameter alarms, high false alarm rates can be expected when calculated over shorter time spans. Further studies are recommended to optimize care escalation criteria for continuous monitoring of vital signs in a ward setting and to evaluate the effects on patient outcomes. JMIR Publications 2023-08-30 /pmc/articles/PMC10500362/ /pubmed/37647104 http://dx.doi.org/10.2196/44483 Text en ©Mathilde C van Rossum, Robin E M Bekhuis, Ying Wang, Johannes H Hegeman, Ellis C Folbert, Miriam M R Vollenbroek-Hutten, Cornelis J Kalkman, Ewout A Kouwenhoven, Hermie J Hermens. Originally published in JMIR Perioperative Medicine (http://periop.jmir.org), 30.08.2023. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Perioperative Medicine, is properly cited. The complete bibliographic information, a link to the original publication on http://periop.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
van Rossum, Mathilde C
Bekhuis, Robin E M
Wang, Ying
Hegeman, Johannes H
Folbert, Ellis C
Vollenbroek-Hutten, Miriam M R
Kalkman, Cornelis J
Kouwenhoven, Ewout A
Hermens, Hermie J
Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study
title Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study
title_full Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study
title_fullStr Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study
title_full_unstemmed Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study
title_short Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study
title_sort early warning scores to support continuous wireless vital sign monitoring for complication prediction in patients on surgical wards: retrospective observational study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10500362/
https://www.ncbi.nlm.nih.gov/pubmed/37647104
http://dx.doi.org/10.2196/44483
work_keys_str_mv AT vanrossummathildec earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy
AT bekhuisrobinem earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy
AT wangying earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy
AT hegemanjohannesh earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy
AT folbertellisc earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy
AT vollenbroekhuttenmiriammr earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy
AT kalkmancornelisj earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy
AT kouwenhovenewouta earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy
AT hermenshermiej earlywarningscorestosupportcontinuouswirelessvitalsignmonitoringforcomplicationpredictioninpatientsonsurgicalwardsretrospectiveobservationalstudy