Cargando…
Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty
BACKGROUND: The aim of this study was to evaluate the precision and feasibility of patient-specific instruments (PSI) in total hip arthroplasty (THA) as compared to the traditional free-hand (FRH) approach. METHODS: During the period of January 1, 2021 to December 31, 2022, a randomized allocation w...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10500796/ https://www.ncbi.nlm.nih.gov/pubmed/37705017 http://dx.doi.org/10.1186/s12938-023-01152-5 |
_version_ | 1785105987949035520 |
---|---|
author | Zheng, Wei Liu, Xuefeng Mei, Runhong Deng, Gaorong Li, Zhipeng Lin, Rongji Xiong, Shui Wu, Binghua |
author_facet | Zheng, Wei Liu, Xuefeng Mei, Runhong Deng, Gaorong Li, Zhipeng Lin, Rongji Xiong, Shui Wu, Binghua |
author_sort | Zheng, Wei |
collection | PubMed |
description | BACKGROUND: The aim of this study was to evaluate the precision and feasibility of patient-specific instruments (PSI) in total hip arthroplasty (THA) as compared to the traditional free-hand (FRH) approach. METHODS: During the period of January 1, 2021 to December 31, 2022, a randomized allocation was used for patients receiving unilateral primary THA to either the PSI or conventional operation group. The placement and size of the PSI were specifically chosen to guide femoral neck resection and prosthesis implantation. The study analyzed component positions and evaluated radiographic and clinical outcomes in 30 patients who received PSI-assisted THAs and 30 patients who received FRH THAs. This study was registered at China Clinical Trial Registry (number: ChiCTR2300072325) on June 9th, 2023. RESULTS: The use of PSI in THA resulted in significantly higher precision in achieving the desired component position as compared to the FRH approach. The PSI group showed significantly smaller absolute errors of femoral anteversion (p < 0.001). No significant differences were found in operation time, intra-operative blood loss, hospitalization duration, or time to walk after surgery. CONCLUSION: In conclusion, the application of patient-specific instruments in THA provides a simple and reliable solution to enhance the precision of femoral prosthesis placement with high accuracy and feasibility. This study highlights the potential benefits of using the PSI in THA. |
format | Online Article Text |
id | pubmed-10500796 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-105007962023-09-15 Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty Zheng, Wei Liu, Xuefeng Mei, Runhong Deng, Gaorong Li, Zhipeng Lin, Rongji Xiong, Shui Wu, Binghua Biomed Eng Online Research BACKGROUND: The aim of this study was to evaluate the precision and feasibility of patient-specific instruments (PSI) in total hip arthroplasty (THA) as compared to the traditional free-hand (FRH) approach. METHODS: During the period of January 1, 2021 to December 31, 2022, a randomized allocation was used for patients receiving unilateral primary THA to either the PSI or conventional operation group. The placement and size of the PSI were specifically chosen to guide femoral neck resection and prosthesis implantation. The study analyzed component positions and evaluated radiographic and clinical outcomes in 30 patients who received PSI-assisted THAs and 30 patients who received FRH THAs. This study was registered at China Clinical Trial Registry (number: ChiCTR2300072325) on June 9th, 2023. RESULTS: The use of PSI in THA resulted in significantly higher precision in achieving the desired component position as compared to the FRH approach. The PSI group showed significantly smaller absolute errors of femoral anteversion (p < 0.001). No significant differences were found in operation time, intra-operative blood loss, hospitalization duration, or time to walk after surgery. CONCLUSION: In conclusion, the application of patient-specific instruments in THA provides a simple and reliable solution to enhance the precision of femoral prosthesis placement with high accuracy and feasibility. This study highlights the potential benefits of using the PSI in THA. BioMed Central 2023-09-13 /pmc/articles/PMC10500796/ /pubmed/37705017 http://dx.doi.org/10.1186/s12938-023-01152-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zheng, Wei Liu, Xuefeng Mei, Runhong Deng, Gaorong Li, Zhipeng Lin, Rongji Xiong, Shui Wu, Binghua Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty |
title | Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty |
title_full | Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty |
title_fullStr | Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty |
title_full_unstemmed | Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty |
title_short | Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty |
title_sort | feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10500796/ https://www.ncbi.nlm.nih.gov/pubmed/37705017 http://dx.doi.org/10.1186/s12938-023-01152-5 |
work_keys_str_mv | AT zhengwei feasibilityandanteversionaccuracyofapatientspecificinstrumentforfemoralprosthesisimplantationintotalhiparthroplasty AT liuxuefeng feasibilityandanteversionaccuracyofapatientspecificinstrumentforfemoralprosthesisimplantationintotalhiparthroplasty AT meirunhong feasibilityandanteversionaccuracyofapatientspecificinstrumentforfemoralprosthesisimplantationintotalhiparthroplasty AT denggaorong feasibilityandanteversionaccuracyofapatientspecificinstrumentforfemoralprosthesisimplantationintotalhiparthroplasty AT lizhipeng feasibilityandanteversionaccuracyofapatientspecificinstrumentforfemoralprosthesisimplantationintotalhiparthroplasty AT linrongji feasibilityandanteversionaccuracyofapatientspecificinstrumentforfemoralprosthesisimplantationintotalhiparthroplasty AT xiongshui feasibilityandanteversionaccuracyofapatientspecificinstrumentforfemoralprosthesisimplantationintotalhiparthroplasty AT wubinghua feasibilityandanteversionaccuracyofapatientspecificinstrumentforfemoralprosthesisimplantationintotalhiparthroplasty |