Cargando…
Nondeformed Ultrasound Image Production Method for Ultrasound-Guided Radiotherapy
Purpose: During ultrasound (US)-guided radiotherapy, the tissue is deformed by probe pressure, and the US image is limited by changes in tissue and organ position and geometry when the US image is aligned with computed tomography (CT) image, leading to poor alignment. Accordingly, a pixel displaceme...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10501062/ https://www.ncbi.nlm.nih.gov/pubmed/37700675 http://dx.doi.org/10.1177/15330338231194546 |
_version_ | 1785106044919218176 |
---|---|
author | Li, Qixuan Zhang, Fan Xi, Qianyi Jiao, Zhuqing Ni, Xinye |
author_facet | Li, Qixuan Zhang, Fan Xi, Qianyi Jiao, Zhuqing Ni, Xinye |
author_sort | Li, Qixuan |
collection | PubMed |
description | Purpose: During ultrasound (US)-guided radiotherapy, the tissue is deformed by probe pressure, and the US image is limited by changes in tissue and organ position and geometry when the US image is aligned with computed tomography (CT) image, leading to poor alignment. Accordingly, a pixel displacement-based nondeformed US image production method is proposed. Methods: The correction of US image deformation is achieved by calculating the pixel displacement of an image. The positioning CT image (CT(std)) is used as the gold standard. The deformed US image (US(def)) is inputted into the Harris algorithm to extract corner points for selecting feature points, and the displacement of adjacent pixels of feature points in the US video stream is calculated using the Lucas-Kanade optical flow algorithm. The moving least squares algorithm is used to correct US(def) globally and locally in accordance with image pixel displacement to generate a nondeformed US image (US(rev)). In addition, US(def) and US(rev) were separately aligned with CT(std) to evaluate the improvement of alignment accuracy through deformation correction. Results: In the phantom experiment, the overall and local average correction errors of the US image under the optimal probe pressure were 1.0944 and 0.7388 mm, respectively, and the registration accuracy of US(def) and US(rev) with CT(std) was 0.6764 and 0.9016, respectively. During the volunteer experiment, the correction error of all 12 patients’ data ranged from −1.7525 to 1.5685 mm, with a mean absolute error of 0.8612 mm. The improvement range of US and CT registration accuracy, before and after image deformation correction in the 12 patients evaluated by a normalized correlation coefficient, was 0.1232 to 0.2476. Conclusion: The pixel displacement-based deformation correction method can solve the limitation imposed by image deformation on image alignment in US-guided radiotherapy. Compared with US(def), the alignment results of US(rev) with CT were better. |
format | Online Article Text |
id | pubmed-10501062 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-105010622023-09-15 Nondeformed Ultrasound Image Production Method for Ultrasound-Guided Radiotherapy Li, Qixuan Zhang, Fan Xi, Qianyi Jiao, Zhuqing Ni, Xinye Technol Cancer Res Treat Developments in the use of multiple imaging modalities for radiotherapy Purpose: During ultrasound (US)-guided radiotherapy, the tissue is deformed by probe pressure, and the US image is limited by changes in tissue and organ position and geometry when the US image is aligned with computed tomography (CT) image, leading to poor alignment. Accordingly, a pixel displacement-based nondeformed US image production method is proposed. Methods: The correction of US image deformation is achieved by calculating the pixel displacement of an image. The positioning CT image (CT(std)) is used as the gold standard. The deformed US image (US(def)) is inputted into the Harris algorithm to extract corner points for selecting feature points, and the displacement of adjacent pixels of feature points in the US video stream is calculated using the Lucas-Kanade optical flow algorithm. The moving least squares algorithm is used to correct US(def) globally and locally in accordance with image pixel displacement to generate a nondeformed US image (US(rev)). In addition, US(def) and US(rev) were separately aligned with CT(std) to evaluate the improvement of alignment accuracy through deformation correction. Results: In the phantom experiment, the overall and local average correction errors of the US image under the optimal probe pressure were 1.0944 and 0.7388 mm, respectively, and the registration accuracy of US(def) and US(rev) with CT(std) was 0.6764 and 0.9016, respectively. During the volunteer experiment, the correction error of all 12 patients’ data ranged from −1.7525 to 1.5685 mm, with a mean absolute error of 0.8612 mm. The improvement range of US and CT registration accuracy, before and after image deformation correction in the 12 patients evaluated by a normalized correlation coefficient, was 0.1232 to 0.2476. Conclusion: The pixel displacement-based deformation correction method can solve the limitation imposed by image deformation on image alignment in US-guided radiotherapy. Compared with US(def), the alignment results of US(rev) with CT were better. SAGE Publications 2023-09-13 /pmc/articles/PMC10501062/ /pubmed/37700675 http://dx.doi.org/10.1177/15330338231194546 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Developments in the use of multiple imaging modalities for radiotherapy Li, Qixuan Zhang, Fan Xi, Qianyi Jiao, Zhuqing Ni, Xinye Nondeformed Ultrasound Image Production Method for Ultrasound-Guided Radiotherapy |
title | Nondeformed Ultrasound Image Production Method for Ultrasound-Guided Radiotherapy |
title_full | Nondeformed Ultrasound Image Production Method for Ultrasound-Guided Radiotherapy |
title_fullStr | Nondeformed Ultrasound Image Production Method for Ultrasound-Guided Radiotherapy |
title_full_unstemmed | Nondeformed Ultrasound Image Production Method for Ultrasound-Guided Radiotherapy |
title_short | Nondeformed Ultrasound Image Production Method for Ultrasound-Guided Radiotherapy |
title_sort | nondeformed ultrasound image production method for ultrasound-guided radiotherapy |
topic | Developments in the use of multiple imaging modalities for radiotherapy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10501062/ https://www.ncbi.nlm.nih.gov/pubmed/37700675 http://dx.doi.org/10.1177/15330338231194546 |
work_keys_str_mv | AT liqixuan nondeformedultrasoundimageproductionmethodforultrasoundguidedradiotherapy AT zhangfan nondeformedultrasoundimageproductionmethodforultrasoundguidedradiotherapy AT xiqianyi nondeformedultrasoundimageproductionmethodforultrasoundguidedradiotherapy AT jiaozhuqing nondeformedultrasoundimageproductionmethodforultrasoundguidedradiotherapy AT nixinye nondeformedultrasoundimageproductionmethodforultrasoundguidedradiotherapy |