Cargando…

Could Testicular Tissue Be a New Arena for the Holmium Laser?

Introduction We aimed to observe the effects of holmium:yttrium-aluminum-garnet (Ho:YAG) laser on testicular tissue. Methods An ex vivo experiment was conducted using calf testicles. A 100 W laser generator with broad-spectrum settings of 10-80 W, 20-40 Hz, and 0.5-2 J, with a medium pulse duration,...

Descripción completa

Detalles Bibliográficos
Autores principales: Karaaslan, Mustafa, Yilmaz, Mehmet, Ordu, Melike, Sirin, Mehmet Emin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10501419/
https://www.ncbi.nlm.nih.gov/pubmed/37720129
http://dx.doi.org/10.7759/cureus.45234
_version_ 1785106112330072064
author Karaaslan, Mustafa
Yilmaz, Mehmet
Ordu, Melike
Sirin, Mehmet Emin
author_facet Karaaslan, Mustafa
Yilmaz, Mehmet
Ordu, Melike
Sirin, Mehmet Emin
author_sort Karaaslan, Mustafa
collection PubMed
description Introduction We aimed to observe the effects of holmium:yttrium-aluminum-garnet (Ho:YAG) laser on testicular tissue. Methods An ex vivo experiment was conducted using calf testicles. A 100 W laser generator with broad-spectrum settings of 10-80 W, 20-40 Hz, and 0.5-2 J, with a medium pulse duration, was tested. The laser effects on testicular tissues with and without the tunica layer were evaluated histopathologically by calculating the incision depth (ID), vaporization area (VA), coagulation area (CA), and total laser area (TLA=VA+CA) of the specimens. Results A total of 48 experiments were conducted. In testicular tissue without a tunica layer, the highest mean ID was determined at 1 J-20 Hz (0.247±0.0208 mm) and with a tunica layer at 2 J-40 Hz (2.673±0.032 mm). In the testicular tissue without a tunica layer, the highest mean VA was determined at 1.5 J-40 Hz (0.029±0.0016 mm(2)) and in tissue with a tunica at 2 J-40 Hz (6.173±0.114 mm(2)). The highest mean TLA in tissue without a tunica was detected at 2 J-20 Hz (0.038±0.0008 mm(2)) and in tissue with a tunica at 2 J-40 Hz (7.292±0.07 mm(2)). The mean ID, VA, CA, and TLA values of all the power outputs used were found to be statistically significantly higher in the testicular tissue with the tunica layer than in that without it (p<0.001). Conclusion The Ho:YAG laser has different effects on testicular tissue with and without a tunica layer. In testicular tissue without a tunica, the laser’s effect was minimal on the surrounding tissue, especially in terms of the ID, VA, and TLA. This minimal effect of the laser can be an advantage in testicular surgery procedures such as testis-sparing surgery (TSS) or testicular sperm extraction (TESE).
format Online
Article
Text
id pubmed-10501419
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-105014192023-09-15 Could Testicular Tissue Be a New Arena for the Holmium Laser? Karaaslan, Mustafa Yilmaz, Mehmet Ordu, Melike Sirin, Mehmet Emin Cureus Urology Introduction We aimed to observe the effects of holmium:yttrium-aluminum-garnet (Ho:YAG) laser on testicular tissue. Methods An ex vivo experiment was conducted using calf testicles. A 100 W laser generator with broad-spectrum settings of 10-80 W, 20-40 Hz, and 0.5-2 J, with a medium pulse duration, was tested. The laser effects on testicular tissues with and without the tunica layer were evaluated histopathologically by calculating the incision depth (ID), vaporization area (VA), coagulation area (CA), and total laser area (TLA=VA+CA) of the specimens. Results A total of 48 experiments were conducted. In testicular tissue without a tunica layer, the highest mean ID was determined at 1 J-20 Hz (0.247±0.0208 mm) and with a tunica layer at 2 J-40 Hz (2.673±0.032 mm). In the testicular tissue without a tunica layer, the highest mean VA was determined at 1.5 J-40 Hz (0.029±0.0016 mm(2)) and in tissue with a tunica at 2 J-40 Hz (6.173±0.114 mm(2)). The highest mean TLA in tissue without a tunica was detected at 2 J-20 Hz (0.038±0.0008 mm(2)) and in tissue with a tunica at 2 J-40 Hz (7.292±0.07 mm(2)). The mean ID, VA, CA, and TLA values of all the power outputs used were found to be statistically significantly higher in the testicular tissue with the tunica layer than in that without it (p<0.001). Conclusion The Ho:YAG laser has different effects on testicular tissue with and without a tunica layer. In testicular tissue without a tunica, the laser’s effect was minimal on the surrounding tissue, especially in terms of the ID, VA, and TLA. This minimal effect of the laser can be an advantage in testicular surgery procedures such as testis-sparing surgery (TSS) or testicular sperm extraction (TESE). Cureus 2023-09-14 /pmc/articles/PMC10501419/ /pubmed/37720129 http://dx.doi.org/10.7759/cureus.45234 Text en Copyright © 2023, Karaaslan et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Urology
Karaaslan, Mustafa
Yilmaz, Mehmet
Ordu, Melike
Sirin, Mehmet Emin
Could Testicular Tissue Be a New Arena for the Holmium Laser?
title Could Testicular Tissue Be a New Arena for the Holmium Laser?
title_full Could Testicular Tissue Be a New Arena for the Holmium Laser?
title_fullStr Could Testicular Tissue Be a New Arena for the Holmium Laser?
title_full_unstemmed Could Testicular Tissue Be a New Arena for the Holmium Laser?
title_short Could Testicular Tissue Be a New Arena for the Holmium Laser?
title_sort could testicular tissue be a new arena for the holmium laser?
topic Urology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10501419/
https://www.ncbi.nlm.nih.gov/pubmed/37720129
http://dx.doi.org/10.7759/cureus.45234
work_keys_str_mv AT karaaslanmustafa couldtesticulartissuebeanewarenafortheholmiumlaser
AT yilmazmehmet couldtesticulartissuebeanewarenafortheholmiumlaser
AT ordumelike couldtesticulartissuebeanewarenafortheholmiumlaser
AT sirinmehmetemin couldtesticulartissuebeanewarenafortheholmiumlaser