Cargando…

Multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin

SIGNIFICANCE: Application of multiexposure speckle contrast imaging (MESI) methods for perfusion measurements can correct for the contribution of static scattering of the skin, at the expense of reduced temporal resolution as compared to classical single-exposure methods. Persistence of tissue scatt...

Descripción completa

Detalles Bibliográficos
Autores principales: Smausz, Tamás, Kondász, Bence
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10502513/
https://www.ncbi.nlm.nih.gov/pubmed/37720190
http://dx.doi.org/10.1117/1.JBO.28.9.096006
_version_ 1785106338736504832
author Smausz, Tamás
Kondász, Bence
author_facet Smausz, Tamás
Kondász, Bence
author_sort Smausz, Tamás
collection PubMed
description SIGNIFICANCE: Application of multiexposure speckle contrast imaging (MESI) methods for perfusion measurements can correct for the contribution of static scattering of the skin, at the expense of reduced temporal resolution as compared to classical single-exposure methods. Persistence of tissue scattering properties during the measurements could allow for an initial calibration and enhancement of the temporal resolution of the measurements. AIM: We aim to study the influence of the perfusion on the light scattering of the forearm skin and to use the obtained data for the enhancement of the temporal resolution. APPROACH: A wide range of skin perfusion states was induced while monitoring the changes in the dynamic range of the exposure-dependent contrast. Different measurement and evaluation methods were tested based on an initial MESI calibration followed by image recording with reduced number of exposure time values. RESULTS: The changes in the skin perfusion can alter not only the contribution of the static scattering to the speckle images but also the short-exposure time contrast limit. CONCLUSIONS: The perfusion-dependent scattering of the skin can invalidate the precalibrations (e.g., [Formula: see text] calibration) characterizing the combination of the given tissue and the measurement system.
format Online
Article
Text
id pubmed-10502513
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-105025132023-09-16 Multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin Smausz, Tamás Kondász, Bence J Biomed Opt Imaging SIGNIFICANCE: Application of multiexposure speckle contrast imaging (MESI) methods for perfusion measurements can correct for the contribution of static scattering of the skin, at the expense of reduced temporal resolution as compared to classical single-exposure methods. Persistence of tissue scattering properties during the measurements could allow for an initial calibration and enhancement of the temporal resolution of the measurements. AIM: We aim to study the influence of the perfusion on the light scattering of the forearm skin and to use the obtained data for the enhancement of the temporal resolution. APPROACH: A wide range of skin perfusion states was induced while monitoring the changes in the dynamic range of the exposure-dependent contrast. Different measurement and evaluation methods were tested based on an initial MESI calibration followed by image recording with reduced number of exposure time values. RESULTS: The changes in the skin perfusion can alter not only the contribution of the static scattering to the speckle images but also the short-exposure time contrast limit. CONCLUSIONS: The perfusion-dependent scattering of the skin can invalidate the precalibrations (e.g., [Formula: see text] calibration) characterizing the combination of the given tissue and the measurement system. Society of Photo-Optical Instrumentation Engineers 2023-09-15 2023-09 /pmc/articles/PMC10502513/ /pubmed/37720190 http://dx.doi.org/10.1117/1.JBO.28.9.096006 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Imaging
Smausz, Tamás
Kondász, Bence
Multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin
title Multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin
title_full Multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin
title_fullStr Multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin
title_full_unstemmed Multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin
title_short Multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin
title_sort multiexposure laser speckle contrast analysis system calibration limited by perfusion-dependent scattering on the skin
topic Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10502513/
https://www.ncbi.nlm.nih.gov/pubmed/37720190
http://dx.doi.org/10.1117/1.JBO.28.9.096006
work_keys_str_mv AT smausztamas multiexposurelaserspecklecontrastanalysissystemcalibrationlimitedbyperfusiondependentscatteringontheskin
AT kondaszbence multiexposurelaserspecklecontrastanalysissystemcalibrationlimitedbyperfusiondependentscatteringontheskin