Cargando…

Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation

BACKGROUND: Accurate sizing of the tricuspid valve annulus is essential for determining the optimal timing of tricuspid valve (TV) intervention. Two-dimensional (2D) echocardiography has limitations for comprehensive TV analysis. Three-dimensional (3D) imaging of the valve provides a better understa...

Descripción completa

Detalles Bibliográficos
Autores principales: Bieliauskienė, Gintarė, Kažukauskienė, Ieva, Kramena, Rita, Zorinas, Aleksejus, Mainelis, Antanas, Zakarkaitė, Diana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10503068/
https://www.ncbi.nlm.nih.gov/pubmed/37715211
http://dx.doi.org/10.1186/s12947-023-00315-7
_version_ 1785106444350128128
author Bieliauskienė, Gintarė
Kažukauskienė, Ieva
Kramena, Rita
Zorinas, Aleksejus
Mainelis, Antanas
Zakarkaitė, Diana
author_facet Bieliauskienė, Gintarė
Kažukauskienė, Ieva
Kramena, Rita
Zorinas, Aleksejus
Mainelis, Antanas
Zakarkaitė, Diana
author_sort Bieliauskienė, Gintarė
collection PubMed
description BACKGROUND: Accurate sizing of the tricuspid valve annulus is essential for determining the optimal timing of tricuspid valve (TV) intervention. Two-dimensional (2D) echocardiography has limitations for comprehensive TV analysis. Three-dimensional (3D) imaging of the valve provides a better understanding of its spatial anatomy and enables more accurate measurements of TV structures. OBJECTIVES: The study aimed to analyze tricuspid annulus (TA) parameters in normal heart and in different grades of functional tricuspid regurgitation (TR); to compare TA measurements obtained by 2D and 3D echocardiography. METHODS: One hundred fifty-five patients (median age 65 years, 57% women) with normal TV and different functional TR grades underwent 2D and 3D transthoracic echocardiography. The severity of TR was estimated using multiparametric assessment according to the guidelines. Mid-systolic 3D TA parameters were calculated using TV dedicated software. The conventional 2D systolic TA measurements in a standard four-chamber view were performed. RESULTS: In mid-systole, the normal TA area was 9.2 ± 2.0 cm(2) for men and 7.4 ± 1.6 cm(2) for women. When indexed to body surface area (BSA), there were no significant differences in the 3D parameters between genders. The 2D TA diameters were smaller than those measured in 3D. The ROC curve analysis identified that all 3D TA parameters can accurately differentiate between different functional TR grades. Additionally, the optimal cut-off values were identified for each TA parameter. CONCLUSIONS: Gender, body size, and age have an impact on the TA parameters in healthy subjects. 2D measurements are smaller than 3D parameters. The reference values for 3D metrics according to TR severity can help in identifying TA dilation and distinguishing between different functional TR grades. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12947-023-00315-7.
format Online
Article
Text
id pubmed-10503068
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-105030682023-09-16 Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation Bieliauskienė, Gintarė Kažukauskienė, Ieva Kramena, Rita Zorinas, Aleksejus Mainelis, Antanas Zakarkaitė, Diana Cardiovasc Ultrasound Research BACKGROUND: Accurate sizing of the tricuspid valve annulus is essential for determining the optimal timing of tricuspid valve (TV) intervention. Two-dimensional (2D) echocardiography has limitations for comprehensive TV analysis. Three-dimensional (3D) imaging of the valve provides a better understanding of its spatial anatomy and enables more accurate measurements of TV structures. OBJECTIVES: The study aimed to analyze tricuspid annulus (TA) parameters in normal heart and in different grades of functional tricuspid regurgitation (TR); to compare TA measurements obtained by 2D and 3D echocardiography. METHODS: One hundred fifty-five patients (median age 65 years, 57% women) with normal TV and different functional TR grades underwent 2D and 3D transthoracic echocardiography. The severity of TR was estimated using multiparametric assessment according to the guidelines. Mid-systolic 3D TA parameters were calculated using TV dedicated software. The conventional 2D systolic TA measurements in a standard four-chamber view were performed. RESULTS: In mid-systole, the normal TA area was 9.2 ± 2.0 cm(2) for men and 7.4 ± 1.6 cm(2) for women. When indexed to body surface area (BSA), there were no significant differences in the 3D parameters between genders. The 2D TA diameters were smaller than those measured in 3D. The ROC curve analysis identified that all 3D TA parameters can accurately differentiate between different functional TR grades. Additionally, the optimal cut-off values were identified for each TA parameter. CONCLUSIONS: Gender, body size, and age have an impact on the TA parameters in healthy subjects. 2D measurements are smaller than 3D parameters. The reference values for 3D metrics according to TR severity can help in identifying TA dilation and distinguishing between different functional TR grades. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12947-023-00315-7. BioMed Central 2023-09-15 /pmc/articles/PMC10503068/ /pubmed/37715211 http://dx.doi.org/10.1186/s12947-023-00315-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Bieliauskienė, Gintarė
Kažukauskienė, Ieva
Kramena, Rita
Zorinas, Aleksejus
Mainelis, Antanas
Zakarkaitė, Diana
Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation
title Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation
title_full Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation
title_fullStr Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation
title_full_unstemmed Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation
title_short Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation
title_sort three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10503068/
https://www.ncbi.nlm.nih.gov/pubmed/37715211
http://dx.doi.org/10.1186/s12947-023-00315-7
work_keys_str_mv AT bieliauskienegintare threedimensionalanalysisofthetricuspidannulargeometryinhealthysubjectsandinpatientswithdifferentgradesoffunctionaltricuspidregurgitation
AT kazukauskieneieva threedimensionalanalysisofthetricuspidannulargeometryinhealthysubjectsandinpatientswithdifferentgradesoffunctionaltricuspidregurgitation
AT kramenarita threedimensionalanalysisofthetricuspidannulargeometryinhealthysubjectsandinpatientswithdifferentgradesoffunctionaltricuspidregurgitation
AT zorinasaleksejus threedimensionalanalysisofthetricuspidannulargeometryinhealthysubjectsandinpatientswithdifferentgradesoffunctionaltricuspidregurgitation
AT mainelisantanas threedimensionalanalysisofthetricuspidannulargeometryinhealthysubjectsandinpatientswithdifferentgradesoffunctionaltricuspidregurgitation
AT zakarkaitediana threedimensionalanalysisofthetricuspidannulargeometryinhealthysubjectsandinpatientswithdifferentgradesoffunctionaltricuspidregurgitation