No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis

INTRODUCTION: Cut-out is the most frequently reported mechanical failure of internal fixation of pertrochanteric fractures. The purpose of this study was to examine if hydroxyapatite-coated screw thread on a sliding hip screw (SHS) could reduce screw migration within the femoral head in patients wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Krogh, August Christoffer, Thillemann, Janni Kjærgaard, Hansen, Torben Bæk, Holck, Kim, Kristensen, Morten Tange, Palm, Henrik, Stilling, Maiken
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10503211/
https://www.ncbi.nlm.nih.gov/pubmed/37710269
http://dx.doi.org/10.1186/s13018-023-04170-0
_version_ 1785106479132442624
author Krogh, August Christoffer
Thillemann, Janni Kjærgaard
Hansen, Torben Bæk
Holck, Kim
Kristensen, Morten Tange
Palm, Henrik
Stilling, Maiken
author_facet Krogh, August Christoffer
Thillemann, Janni Kjærgaard
Hansen, Torben Bæk
Holck, Kim
Kristensen, Morten Tange
Palm, Henrik
Stilling, Maiken
author_sort Krogh, August Christoffer
collection PubMed
description INTRODUCTION: Cut-out is the most frequently reported mechanical failure of internal fixation of pertrochanteric fractures. The purpose of this study was to examine if hydroxyapatite-coated screw thread on a sliding hip screw (SHS) could reduce screw migration within the femoral head in patients with stable pertrochanteric fractures. MATERIALS AND METHODS: In a double-blinded randomized controlled study, 37 patients at mean age 78 (range 56–96), with pertrochanteric fracture (Evans I, II, IV) received surgery with a SHS with a hydroxyapatite-coated or a non-coated lag screw thread. Radiostereometry and standard radiographs were obtained 1 day, 6 weeks, 3- and 6 months post-operatively to evaluate screw and fracture migration and fracture reposition. The two groups were combined to describe fracture migration. RESULTS: There was similar and small screw migration in the femoral head between the two groups at 6 weeks, 3- and 6 months (p > 0.12). Fracture migration occurred predominantly in the first 6 weeks, where fracture impaction was 5.95 mm (CI 95% 2.87 to 9.04) and anterior rotation of the femoral head was -2.94° (CI 95% − 5.22 to − 0.66). Migration of the fracture (total translation) correlated to the post-operative fracture reposition (p = 0.002), but not significantly to screw migration (p = 0.09). Neither screw total translation (rho 0.06, p = 0.79) nor fracture total translation (rho 0.04, p = 0.77) correlated with bone mineral density. CONCLUSION: There was no clinical benefit of hydroxyapatite coating on lag screw migration in this patient cohort. Migration of the pertrochanteric fractures was higher with poor fracture reposition but fractures generally stabilized after 6 weeks follow-up. The study was registered at ClinicalTrials.gov (NCT05677061). LEVEL OF EVIDENCE II: Patient-blinded prospective randomized study. Trial registration number The study was registered at ClinicalTrials.gov (NCT05677061).
format Online
Article
Text
id pubmed-10503211
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-105032112023-09-16 No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis Krogh, August Christoffer Thillemann, Janni Kjærgaard Hansen, Torben Bæk Holck, Kim Kristensen, Morten Tange Palm, Henrik Stilling, Maiken J Orthop Surg Res Research Article INTRODUCTION: Cut-out is the most frequently reported mechanical failure of internal fixation of pertrochanteric fractures. The purpose of this study was to examine if hydroxyapatite-coated screw thread on a sliding hip screw (SHS) could reduce screw migration within the femoral head in patients with stable pertrochanteric fractures. MATERIALS AND METHODS: In a double-blinded randomized controlled study, 37 patients at mean age 78 (range 56–96), with pertrochanteric fracture (Evans I, II, IV) received surgery with a SHS with a hydroxyapatite-coated or a non-coated lag screw thread. Radiostereometry and standard radiographs were obtained 1 day, 6 weeks, 3- and 6 months post-operatively to evaluate screw and fracture migration and fracture reposition. The two groups were combined to describe fracture migration. RESULTS: There was similar and small screw migration in the femoral head between the two groups at 6 weeks, 3- and 6 months (p > 0.12). Fracture migration occurred predominantly in the first 6 weeks, where fracture impaction was 5.95 mm (CI 95% 2.87 to 9.04) and anterior rotation of the femoral head was -2.94° (CI 95% − 5.22 to − 0.66). Migration of the fracture (total translation) correlated to the post-operative fracture reposition (p = 0.002), but not significantly to screw migration (p = 0.09). Neither screw total translation (rho 0.06, p = 0.79) nor fracture total translation (rho 0.04, p = 0.77) correlated with bone mineral density. CONCLUSION: There was no clinical benefit of hydroxyapatite coating on lag screw migration in this patient cohort. Migration of the pertrochanteric fractures was higher with poor fracture reposition but fractures generally stabilized after 6 weeks follow-up. The study was registered at ClinicalTrials.gov (NCT05677061). LEVEL OF EVIDENCE II: Patient-blinded prospective randomized study. Trial registration number The study was registered at ClinicalTrials.gov (NCT05677061). BioMed Central 2023-09-14 /pmc/articles/PMC10503211/ /pubmed/37710269 http://dx.doi.org/10.1186/s13018-023-04170-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Krogh, August Christoffer
Thillemann, Janni Kjærgaard
Hansen, Torben Bæk
Holck, Kim
Kristensen, Morten Tange
Palm, Henrik
Stilling, Maiken
No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis
title No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis
title_full No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis
title_fullStr No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis
title_full_unstemmed No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis
title_short No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis
title_sort no effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10503211/
https://www.ncbi.nlm.nih.gov/pubmed/37710269
http://dx.doi.org/10.1186/s13018-023-04170-0
work_keys_str_mv AT kroghaugustchristoffer noeffectofhydroxyapatitecoatedslidinghipscrewthreadsonscrewmigrationinthefemoralheadneckofpertrochantericfracturesarandomizedcontrolledtrialusingradiostereometricanalysis
AT thillemannjannikjærgaard noeffectofhydroxyapatitecoatedslidinghipscrewthreadsonscrewmigrationinthefemoralheadneckofpertrochantericfracturesarandomizedcontrolledtrialusingradiostereometricanalysis
AT hansentorbenbæk noeffectofhydroxyapatitecoatedslidinghipscrewthreadsonscrewmigrationinthefemoralheadneckofpertrochantericfracturesarandomizedcontrolledtrialusingradiostereometricanalysis
AT holckkim noeffectofhydroxyapatitecoatedslidinghipscrewthreadsonscrewmigrationinthefemoralheadneckofpertrochantericfracturesarandomizedcontrolledtrialusingradiostereometricanalysis
AT kristensenmortentange noeffectofhydroxyapatitecoatedslidinghipscrewthreadsonscrewmigrationinthefemoralheadneckofpertrochantericfracturesarandomizedcontrolledtrialusingradiostereometricanalysis
AT palmhenrik noeffectofhydroxyapatitecoatedslidinghipscrewthreadsonscrewmigrationinthefemoralheadneckofpertrochantericfracturesarandomizedcontrolledtrialusingradiostereometricanalysis
AT stillingmaiken noeffectofhydroxyapatitecoatedslidinghipscrewthreadsonscrewmigrationinthefemoralheadneckofpertrochantericfracturesarandomizedcontrolledtrialusingradiostereometricanalysis