Cargando…
Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia
BACKGROUND: Corneal cross-linking (CXL) is a safe and effective procedure for slowing keratectasia progression in eyes with a corneal thickness of at least 400 µm. Limited research has evaluated the safety and efficacy of epi-off CXL in corneas thinner than 400 µm. OBJECTIVE: To evaluate the safety...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10504847/ https://www.ncbi.nlm.nih.gov/pubmed/37720204 http://dx.doi.org/10.1177/25158414231197064 |
_version_ | 1785106818078343168 |
---|---|
author | Nieuwsma, Abigail Vander Zee, Brandon L. Berdahl, John P. Ibach, Mitch Ferguson, Tanner J. Terveen, Daniel |
author_facet | Nieuwsma, Abigail Vander Zee, Brandon L. Berdahl, John P. Ibach, Mitch Ferguson, Tanner J. Terveen, Daniel |
author_sort | Nieuwsma, Abigail |
collection | PubMed |
description | BACKGROUND: Corneal cross-linking (CXL) is a safe and effective procedure for slowing keratectasia progression in eyes with a corneal thickness of at least 400 µm. Limited research has evaluated the safety and efficacy of epi-off CXL in corneas thinner than 400 µm. OBJECTIVE: To evaluate the safety and efficacy of CXL to slow keratectasia progression in eyes with <400 µm preoperative corneal thickness. DESIGN: Retrospective chart review. METHODS: This retrospective chart review included 37 eyes who underwent epi-off, iso-osmolar riboflavin corneal CXL with a preoperative thinnest point of the cornea <400 µm and had at least 6–12 months of follow-up. Preoperative and postoperative uncorrected visual acuity, best-corrected visual acuity (BCVA), thinnest point of the cornea, flat keratometry, steep keratometry, maximum keratometry (K(max)), need for penetrating keratoplasty, and cases of endothelial failure were recorded. Data were collected at baseline and months 3, 6, 9, and 12 post-CXL. RESULTS: Following cross-linking, 18 eyes (47%) had improved BCVA, 13 (35%) had an unchanged BCVA, and 6 eyes (16%) had a worse BCVA (p = 0.05). The mean postoperative BCVA was 20/81 (0.61 LogMAR) compared to 20/121 (0.78 LogMAR) preoperatively (p = 0.06). K(max) decreased an average of 1.1 D at 3-month (p = 0.53) and 3.4 D at the furthest follow-up (p = 0.10). At the farthest follow-up, 22.7% of eyes had >1 D of K(max) steepening. No patients required keratoplasty and there were no cases of endothelial failure in the follow-up period. CONCLUSION: This research supports the safety and efficacy of epi-off, iso-osmolar CXL in eyes with <400 μm baseline corneal thickness with no patients requiring penetrating or endothelial keratoplasty, a trend toward improvement in BCVA, and K(max) flattening. In the future, prospective studies would be helpful to confirm these findings. |
format | Online Article Text |
id | pubmed-10504847 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-105048472023-09-17 Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia Nieuwsma, Abigail Vander Zee, Brandon L. Berdahl, John P. Ibach, Mitch Ferguson, Tanner J. Terveen, Daniel Ther Adv Ophthalmol Original Research BACKGROUND: Corneal cross-linking (CXL) is a safe and effective procedure for slowing keratectasia progression in eyes with a corneal thickness of at least 400 µm. Limited research has evaluated the safety and efficacy of epi-off CXL in corneas thinner than 400 µm. OBJECTIVE: To evaluate the safety and efficacy of CXL to slow keratectasia progression in eyes with <400 µm preoperative corneal thickness. DESIGN: Retrospective chart review. METHODS: This retrospective chart review included 37 eyes who underwent epi-off, iso-osmolar riboflavin corneal CXL with a preoperative thinnest point of the cornea <400 µm and had at least 6–12 months of follow-up. Preoperative and postoperative uncorrected visual acuity, best-corrected visual acuity (BCVA), thinnest point of the cornea, flat keratometry, steep keratometry, maximum keratometry (K(max)), need for penetrating keratoplasty, and cases of endothelial failure were recorded. Data were collected at baseline and months 3, 6, 9, and 12 post-CXL. RESULTS: Following cross-linking, 18 eyes (47%) had improved BCVA, 13 (35%) had an unchanged BCVA, and 6 eyes (16%) had a worse BCVA (p = 0.05). The mean postoperative BCVA was 20/81 (0.61 LogMAR) compared to 20/121 (0.78 LogMAR) preoperatively (p = 0.06). K(max) decreased an average of 1.1 D at 3-month (p = 0.53) and 3.4 D at the furthest follow-up (p = 0.10). At the farthest follow-up, 22.7% of eyes had >1 D of K(max) steepening. No patients required keratoplasty and there were no cases of endothelial failure in the follow-up period. CONCLUSION: This research supports the safety and efficacy of epi-off, iso-osmolar CXL in eyes with <400 μm baseline corneal thickness with no patients requiring penetrating or endothelial keratoplasty, a trend toward improvement in BCVA, and K(max) flattening. In the future, prospective studies would be helpful to confirm these findings. SAGE Publications 2023-09-15 /pmc/articles/PMC10504847/ /pubmed/37720204 http://dx.doi.org/10.1177/25158414231197064 Text en © The Author(s), 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Nieuwsma, Abigail Vander Zee, Brandon L. Berdahl, John P. Ibach, Mitch Ferguson, Tanner J. Terveen, Daniel Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia |
title | Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia |
title_full | Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia |
title_fullStr | Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia |
title_full_unstemmed | Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia |
title_short | Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia |
title_sort | evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10504847/ https://www.ncbi.nlm.nih.gov/pubmed/37720204 http://dx.doi.org/10.1177/25158414231197064 |
work_keys_str_mv | AT nieuwsmaabigail evaluatingthesafetyandefficacyofepioffcornealcrosslinkinginpatientswiththincorneasduetokeratectasia AT vanderzeebrandonl evaluatingthesafetyandefficacyofepioffcornealcrosslinkinginpatientswiththincorneasduetokeratectasia AT berdahljohnp evaluatingthesafetyandefficacyofepioffcornealcrosslinkinginpatientswiththincorneasduetokeratectasia AT ibachmitch evaluatingthesafetyandefficacyofepioffcornealcrosslinkinginpatientswiththincorneasduetokeratectasia AT fergusontannerj evaluatingthesafetyandefficacyofepioffcornealcrosslinkinginpatientswiththincorneasduetokeratectasia AT terveendaniel evaluatingthesafetyandefficacyofepioffcornealcrosslinkinginpatientswiththincorneasduetokeratectasia |